R
rodriguezmichaelAug 19, 2025
What to do if the fan is working but I can't hear the HF arc striking and wiping arc welding won't strike an arc on my wsm 200M?
- CChristopher SmithAug 19, 2025
If the fan is working, the abnormal indicator is not lit, you can't hear the sound of HF arc striking, and wiping arc welding can't strike an arc, it could be due to several reasons. The circuit might be broken, or the silicon bridge might have poor contact; measure the voltage of the positive and negative electrodes from the power board to the VH-07 insert of the MOS board with a multimeter – it should read DC 308V. Also, some of the four high electrolytic capacitors (about 470UF/450V) on the power panel might be leaking. The auxiliary power could be out of work, in this case contact your dealer. Check if all kinds of connect and insert cables have poor contact. There could also be a control circuit problem, in this case contact your dealer. The control cable of the torch might be broken.