Abnormal indicator is
not lit, sound of HF
arc-striking can be
heard, no welding
output
Cable of torch is broken.
Grounding cable is broken or not connected to work piece.
There is relaxation between output terminal of positive electrode, gas-
electricity system output terminal and inner machine.
Abnormal indicator is
not lit, sound of HF
arc-striking can not
be heard, wiping
welding can strike
arc.
Primary cable of arc-striking transformer is poor contact with power
board, tighten it again.
Arc-striking tip is oxidized or distance is too far, get rid of film oxide of
burner or adjust the distance between burners to be 1mm.
Switch (sticking/argon-arc welding) is damaged, replace it.
Some of HF arc-striking circuit components is damage, find out and
replace it.
Abnormal indicator is
lit, no welding output.
Overload current protection may start, please turn off machine first, then
restart it after abnormal indicator is off.
Overheat protection may start. It will become normal in 2-3 min.
Inverter circuit may go wrong, please disconnect the power supply plug
of the main transformer on MOS board (close to insert of fan VH-07)
then restart the machine.
(1) If abnormal indicator is still on, turn off machine and disconnect
power supply plug of HF arc-striking power source (close to insert of
fan VH-07), then restart machine:
a) If abnormal indicator is still on, some fieldistors on MOS board
are damaged, find out and replace them with same model.
b) If abnormal indicator is off, up-slope transformer of HF arc-
striking circuit is damaged, replace it.
(2) If abnormal indicator is off:
a) Maybe transformer on middle board is damage, measure
primary inductance volume and Q value of main transformer by
inductance bridge (L=0.9-1.6mH Q>35). If value is too low,
please replace it.
b) Maybe secondary rectifier tube of transformer is damaged, find
out faults and replace rectifier tube with same model.
Maybe feedback circuit is open.