CLOSED = access to the one time configuration items on the
DEP is enabled.
OPEN = access to the one time config items on the DEP is
disabled.
One-time configuration items are the items on the DEP in the
yellow area of the Config column. These items are the weld
transformer Turns Ratio, AVC set point, Program Lockout,
Network ID, Cal Line Voltage and Cal CURRENT of the Data
Entry Panel. Access to these instructions is restricted because
once they are set up, they should never be changed. Cal Line
Voltage and Cal Current values are set at the factory and should
NOT be changed. If they are changed, your control may not
operate properly until properly re-calibrated. A special keystroke
sequence is needed to change calibration values so they are not
changed accidentally.