NWT4000-2 RF DIGITAL
SWEEPER & ANALYZER
USER MANUAL
Manufacturer:
WUTONG ELECTRONIC
sitehttp://bg7tbl.taobao.com
TEL: +86134 2795 9750
Q Q: 1630 2767
Email: bg7tbl@126.com
version: V2.0
date: 2014-10-20
This document is based on the original manual from the supplier, edited
and updated by Kurt Poulsen (OZ7OU)
The document and applied editing and updates devoted entirely to
document the NWT4000-2 25MHz-4.4GHz unit (using 2xADF4351 PLL’s)but will
also be useful for the NWT4000-2 and NWT4000-1 series going from 138MHz to
4.4GHz (using 2xADF4350 PLL’s). However, the latest NWT4000-2 where the
SMD connector are on top of the PCB (and not at the edge) has improved
screening and far better dynamic range. Watch our when building it into a case
to use a plastic case. Using a metal case will most likely give elevated noise
floor by several dB in the GHz region.
Watch out that you do not purchase the version in a case with two SMA
connectors and a Green LED in between (believing it is a NWT4000 version), as
it most likely will only have 1 PLL (ADF4350 for 138MHz version and ADF4351
for 25MHz version) and thus only is a signal generator and spectrum analyzer,
not being able to sweep the frequency response of devices.
May 2015 edition

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Wutong Electronic NWT4000-1 and is the answer not in the manual?

Wutong Electronic NWT4000-1 Specifications

General IconGeneral
Frequency Range9 kHz to 4 GHz
Output Impedance50 Ω
InterfaceUSB, LAN
Weight4.5 kg
Output Power0 dBm
DisplayTFT LCD
Power SupplyAC 100-240V, 50/60Hz

Summary

Instrumental composition and technical characteristics

Basic parameters and accuracy

Details fundamental parameters, system accuracy, and physical characteristics of NWT models.

Conditions of use

Hardware connection and software guide

WINNWT software installation

Guides through the installation process of the WINNWT software and USB driver.

Logarithmic Y scale sweep frequency settings

SWR measurements

SWR measurement procedures

Details SWR measurement, frequency settings, and calibration using an external bridge.

Impedance - |Z| measurements

Measuring device connection methods

Spectrum Analyzer

Spectrum Analyzer functionality

Explains how the NWT4000-2 functions as a spectrum analyzer using its PLL.

Wattmeter functions

Wattmeter usage and calibration

Details how to use and calibrate the Wattmeter for accurate measurements.

The VFO mode

Frequency calibration

Calibration preparation and setup

Details preparation for 1GHz calibration and setting VFO mode for measurement.

Appendix 4: Sweep calibration and frequency calibration

NWT4000 sweep calibration steps

Outlines the general procedure for calibrating NWT4000 sweep functions.

Flatness calibration procedure

Details the specific steps for achieving flat frequency response calibration.

Frequency calibration procedure

Explains the procedure for calibrating the instrument's frequency accuracy.