EasyManua.ls Logo

Xinje XP-18 Series - 2. Input Specifications and Connection; Basic Input Signal Specifications; Input Connection Diagrams

Xinje XP-18 Series
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
2. In-out specs and exterior layout
2-1. Input specs
DC power
R3
R4
R2
R1
X*7
X*0
COM
supply
Because there is no 24V power supply inside XP/XMP, it needs an outside supplier to drive the
photo-electricity switch sensor. The supplier should be DC 24V±4V. The output transistor of
sensor should be NPN open collector.
DC power
DC24V
power supply
R3
R4
R2
R1
X*7
X*0
COM
+5V
R5R6
LED
I=7mA
sensor
supply
Input signal’s
voltage
DC24V±10%
Input signal’s
current
7mA/DC24V
Input ON current Above 4.5mA
Input OFF current
Below 1.5mA
Input response time
About 10ms
Input signal’s
format
Contact input or
NPN open collector
transistor
Circuit insulation Photo-electricity
coupling insulation
Input action’s
display
LED light when
input ON
Basic unit
Input connection

Related product manuals