Guarantee
UK: This fan is guaranteed against defects for 3 years from the date of purchase.
Xpelair reserve the right to repair or replace the fan.
Keep your purchase receipt.
Any problems, contact the address below.
Outside UK: See International section below.
Technical Advice & Service
UK - Xpelair have a comprehensive range of services including:
Free technical advice Help-Desk from Engineers on all aspects of ventilation.
Free design service, quotations and site surveys.
Outside UK: See International section below.
Please ask for details on:
Tel +44 (0) 8709 000430
Fax +44 (0) 8709 000530
Also at the address below
Head Office – UK Sales Office and Spares
Applied Energy Products Ltd, Morley Way, Peterborough, PE2 9JJ, England
Tel: +44 (0) 1733 456789
Fax: +44 (0) 1733 310606
Sales/Spares Hotline: +44 (0) 8709 000420
Sales/Spares Faxline: +44 (0) 8709 000520
Web: http://www.xpelair.co.uk
International
Guarantee Contact your local distributor or Xpelair direct
Technical advice and Service - Contact your local Xpelair distributor.
567-2066-02
Revision A
GB
F
D
NL
N
S
I
GR
a
Xpelair
Condensation Control Fans
CF20 Pull Cord
CF20T Pull Cord/Timer
Remote Switched Centrifugal Ducted Fans
DX200 Remote Switch
DX200T Remote Switch/Timer
Installation and operating instructions
Please retain for end user’s future reference
ES
Revision B
Redring Xpelair Group Ltd., Newcombe House, Newcombe Way,
Orton Southgate, Peterborough, PE2 6SE England
Redring Xpelair Group Ltd.
567-2066-02
(Revision C)
Guarantee
UK: This fan is guaranteed against defects for 3 years from the date of purchase.
Xpelair reserve the right to repair or replace the fan.
Keep your purchase receipt.
Any problems, contact the address below.
Outside UK: See International section below.
Technical Advice & Service
UK - Xpelair have a comprehensive range of services including:
Free technical advice Help-Desk from Engineers on all aspects of ventilation.
Free design service, quotations and site surveys.
Outside UK: See International section below.
Please ask for details on:
Tel +44 (0) 8709 000430
Fax +44 (0) 8709 000530
Also at the address below
Head Office UK Sales Office and Spares
Applied Energy Products Ltd, Morley Way, Peterborough, PE2 9JJ, England
Tel: +44 (0) 1733 456789
Fax: +44 (0) 1733 310606
Sales/Spares Hotline: +44 (0) 8709 000420
Sales/Spares Faxline: +44 (0) 8709 000520
Web: http://www.xpelair.co.uk
International
Guarantee – Contact your local distributor or Xpelair direct
Technical advice and Service - Contact your local Xpelair distributor.
567-2066-02
Revision A
GB
F
D
NL
N
S
I
GR
a
Xpelair
Condensation Control Fans
CF20 Pull Cord
CF20T
Pull Cord/Timer
Remote Switched Centrifugal Ducted Fans
DX200 Remote Switch
DX200T Remote Switch/Timer
Installation and operating instructions
Please retain for end user’s future reference
ES
Revision B
Question and Answer IconNeed help?

Do you have a question about the Xpelair CF20 and is the answer not in the manual?

Xpelair CF20 Specifications

General IconGeneral
Voltage230 V
IP RatingIPX4
Frequency50 Hz
Airflow200 m³/h
MountingWall

Summary

Guarantee and Service Information

UK Warranty Details

Fan is guaranteed against defects for 3 years from date of purchase.

Outside UK Warranty

See International section for warranty and service contact details.

Technical Advice and Service

UK Services Offered

Xpelair offers free technical advice, design service, quotations, and site surveys.

Contact for Technical Details

Please ask for details on telephone and fax numbers provided.

Head Office and International Contacts

UK Office Contact Information

Provides address, Tel, Fax, Sales/Spares Hotline, and Web details for the UK office.

International Guarantee Contact

Contact local distributor or Xpelair direct for guarantee claims.

International Service Contact

Contact local Xpelair distributor for technical advice and service.

Product Wiring Diagrams

DX200 Wiring

Electrical schematic for the DX200 model, showing connections and components.

CF20 Wiring

Electrical schematic for the CF20 model, including lamp connections.

CF20T / DX200T Wiring

Electrical schematic for CF20T/DX200T models, showing multiple settings.

Ancillary Options

Installation Accessories List

List of optional accessories to aid installation, presented in Spanish and Arabic.

IMPORTANT INSTALLATION GUIDELINES (GB)

General Installation Requirements

Covers regulations, qualified electrician, and electrical supply checks.

Site Selection and Precautions

Guidance on placement away from heat sources and ventilation safety.

Condensation Trap Requirement

Requirement to fit a condensation trap if ductwork is higher than the fan.

Mounting Methods Overview

Introduces various mounting options: wall/ceiling, surface/flush.

Wall Mounting - Surface

Step-by-step instructions for surface mounting the fan on a wall.

Wall Mounting - Flush

Step-by-step instructions for flush mounting the fan on a wall.

Ceiling Mounting - Surface

Step-by-step instructions for surface mounting the fan on a ceiling.

Ceiling Mounting - Flush

Step-by-step instructions for flush mounting the fan on a ceiling.

Fan Preparation Steps

Instructions for preparing the fan unit, including cover removal and tape application.

Fan Adjustment Settings

Covers setting fan speed, trickle speed, and time delay start.

Final Mounting Procedures

Steps for physically mounting the fan box to the wall or ceiling.

User Adjustments and Fan Operation

DX200 User Adjustments

Notes that the DX200 model has no user adjustments.

DX200T Timer Adjustment

Details on adjusting the timer over-run period for the DX200T model.

CF20 Humidity Adjustment

Details on adjusting the humidity setting for the CF20 model.

CF20T Timer and Humidity Settings

Details on adjusting timer and humidity settings for the CF20T model.

DX200 Fan Operation

Instructions for operating the DX200 fan using an external switch.

DX200T Fan Operation

Instructions for operating the DX200T fan, including timer and speed settings.

Time Delay Start Feature

Explanation of the time delay start feature for fans with this option.

Switched Operation Modes

Describes operation with separate on/off and pull cord switches.

Cleaning and Maintenance

Power Disconnection for Cleaning

Safety instruction to disconnect power before cleaning the fan unit.

Exterior Cleaning Method

Guidance on proper cleaning methods for the fan's exterior surface.

Related product manuals