XtraVac CM800 Chamber Machine Operation and Parts Manual
XtraVac Packaging Machines 419 E. 11th Ave. North Kansas City, MO 64116 USA
CM800 Chamber Machine +1 (800) 729-2999 Sales@XtraVac.com
37
A
B
C
D
E
A
B
C
D
E
PAGE
08
Part list
DATE NAME
PROCESSED
CHECKED
STANDARD
Description & function
Item designation Technical date
Q'ty Supplier
Remarks Illustration
PW
T1
PR
TIMER
K1
M1
Y1
Y4
Q1
PCB
Y2
Y3
LS1
R1
Power supply
Sealing transformer
Phase reversal
SealingTIMER
motor
Vacuum valve
Air inlet valve
Power switch
PCB
Gas valve
Sealing valve
Limit switch
Sealing line
ANLY
ANLY
BUSCH
TEND
APR-3
1
1
1
1
1
1
1
1
1
1
1
1
1
-
~
0V
50V
0V
PE
8
5
1
2
~
3
M
Y1
Y4
Y2.1
Y3
COM
NO
2
1
Q1
MEAN WELL
SHINN JIA
MOELLER
PD-45B
AH3-3
P1-25/E
TZ7144
DC 24V
DV 24V
DC 24V
Iu: 25A 690V AC
DC 24V
DC 24V
10A 250VAC
JAW FENG
MC1
MC1 Magnetic Starters
1TEND
TMS16
DC 24V
1
TEND
AC 220V
AC 220V
TC11
Sealing magnetic contactor
SJ-1-200
Xtra Vac
Xtra Vac
R5 0100
AAA
AAA
IWK25-5
IWK25-5
Diamond
Diamond
DA-8
DA-8