3.3 Nitrogen filling time display(C): display the current setting of nitrogen filling time
(unit: 1/s)
3.4 Sealing time display(D): display the current setting of sealing time (unit: 0.1/s)
3.5 Cooling time display(E): display the current setting of cooling time (unit: 0.1/s)
3.6 Memory release key(F): press key for modifying memory function
3.7 Memory input key(G): press key for locking memory function
3.8 Reserved key(H): key reserved for further use.
3.9 E-stop key(I): make timing function stop, and release the upper lid.
3.10 Time increase key(J): press key for time adding
3.11 Time decrease key(K): press key for time reducing
3.12 Sequence of trial run:
3.12.1 Connect the power.
3.12.2 Connect the pneumatic source by quick connector.(C-25)
3.12.3 If the running condition sounds smoothly, it’s clockwise rotating. If there is abnormal
noise coming out, it’s counterclockwise rotating, and please turn off the machine
immediately. Then, change the power wires.
Attention: remember to ground the machine.
3.12.4 Packaging test:
(A) Test the sealing temperature and adjust the sealing time in accordance with Chapter 3
page 10(D).
(B) Test the vacuum degree and adjust the vacuum time in accordance with Chapter 3 page
10(B).
3.12.5 If everything is OK, operate the machine according to the instructions in Chapter 4 for
normal production.