EasyManua.ls Logo

Xtreme Power 75132 - User Manual

Xtreme Power 75132
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ABOVE GROUND POOL SAND FILTER PUMP 2400GPH
SAVE THIS MANUAL: KEEP THIS MANUAL FOR SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY,
OPERATING, INSPECTION, MAINTENANCE AND CLEANING PROCEDURES. WRITE THE PRODUCT’S
SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM (OR MONTH
AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER).
OWNER’S MANUAL AND SAFETY INSTRUCTIONS
ITEM: 75132
FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT: (909) 628 0880 MON-FRI 9AM TO 3PM PST
Question and Answer IconNeed help?

Do you have a question about the Xtreme Power 75132 and is the answer not in the manual?

Summary

Important Safety Information

General Safety Warnings

Core safety warnings about serious injury or death if not installed/used correctly.

Installation and Operation Guidelines

Covers temperature limits, qualified installers, local codes, chemical storage, parts, and pump size.

Pressure and Electrical Hazards

Warnings about tank separation due to pressure and high voltage shock hazards.

Suction Entrapment Hazard

Dangers of suction entrapment and compliance with pool safety acts.

Servicing Safety Procedures

Steps for safely servicing the circulating system, including pressure release.

Operational Safety Precautions

Warnings about filtration adequacy, valve operation, chemical damage, and electrical safety.

Electrical Connection Safety

GFCI requirements, cord usage, and grounding for electrical connections.

Installation

Sand Filtration Working Principle

Explains the process of water filtration through sand.

Preparation Before Installation

Steps for site selection, filter placement, and ensuring proper positioning.

Filter Tank Assembly

Instructions for adding sand and attaching the valve to the filter tank.

Connecting Components

Steps for connecting the sand tank to the pump with hoses and adapters.

Installation Notes and Best Practices

Important tips for proper installation, including valve and hose connection best practices.

Operation and Valve Functions

System Startup Procedure

Step-by-step guide to prime and start the pump system safely.

Filter Control Valve Functions

Explains the purpose and operation of FILTER, BACKWASH, RINSE, and WASTE valve positions.

Parts List

Component Identification

Diagram and detailed list of all parts included with the pump and filter system.

Important Information and Support

Repair and Warranty Disclaimer

States that repairs should be done by certified technicians and disclaims buyer liability.

Customer Support Contact

Provides contact details for customer support regarding questions, problems, or missing parts.

Overview

This document is an owner's manual and safety instructions for an Xtreme Power Above Ground Pool Sand Filter Pump, model 75132, with a capacity of 2400 GPH. It provides critical safety warnings, installation guidelines, operational procedures, and a parts list.

Function Description:

The Xtreme Power Sand Filter Pump is designed for filtering water in above-ground swimming pools and spas. It operates by directing incoming water from the piping system through a multi-port valve to the top of the filter bed. As water passes through the filter sand, dirt and debris are trapped. The filtered water is then returned from the bottom of the filter tank, through the multi-port valve, and back into the piping system. The multi-port valve allows for various operational modes, including filtering, backwashing, rinsing, and waste.

Important Technical Specifications:

  • Model: 75132
  • Capacity: 2400 GPH (Gallons Per Hour)
  • Water Temperature Range: Designed to work with water temperatures > 0°C and < 45°C. Operating outside this range may cause damage.
  • Sand Filter Capacity:
    • 12" sand filter: Requires approximately 19kg of sand.
    • 14" sand filter: Requires approximately 27kg of sand.
  • Pump Options (listed in parts list):
    • 0.25HP Pump (Part #15)
    • 0.35HP Pump (Part #16, #17) - Note: Two parts are listed as .35HP Pump, likely indicating different configurations or components related to this horsepower.
  • Hose Size: 1/14" (32mm) x 45cm hose (Part #14)
  • Pressure Gauge: Included (Part #20)
  • Electrical Safety: Requires connection to a ground type receptacle protected by a Ground Fault Circuit Interrupter (GFCI). Article 681-31 of the NEC requires a GFCI for pumps used with storable pools. The motor must be grounded before connecting to the AC power supply. Extension cords should not be used.

Usage Features:

  • Multi-Port Valve Functions:
    • FILTER: Standard mode for normal filtering and regular vacuuming.
    • BACKWASH: Used for cleaning the filter bed when the pressure gauge reading rises 8-10 PSI (0.55 - 0.69 BAR) above the initial "clean" pressure. The pump is stopped, the valve is set to BACKWASH, and the pump is run until the sight window shows clear water (approximately 2 minutes or less).
    • RINSE: Performed after backwashing to flush dirty water from the filter to waste, preventing it from returning to the pool. The pump is stopped, the valve is set to RINSE, and the pump is run for about 0.5 - 1 minute.
    • WASTE: Bypasses the filter for draining the pool, lowering the water level, or vacuuming heavy debris directly to waste.
  • Pressure Monitoring: A pressure gauge is included to indicate when backwashing is necessary.
  • Ease of Installation: The manual provides step-by-step instructions for assembling the sand tank, diffuser body, adding sand, and connecting the multi-port valve and pump.
  • Positioning Guidelines: The filter should be placed as close to the pool/spa as possible, on a level, concrete slab, firm ground, or equivalent, and near piping for convenient operation and servicing. The compliance label should face forward for easy identification.
  • Pump Operation: All suction and discharge valves must be open when starting the system. The filter vessel should be full of water before pump start-up to prevent damage. The pump must always be turned off before changing valve positions to prevent damage to the control valve and potential injury.

Maintenance Features:

  • Regular Backwashing and Rinsing: Essential for maintaining filter efficiency and water clarity, performed when the pressure gauge indicates a rise in pressure.
  • System Inspection: Regular inspection of all connections for security is required.
  • Part Replacement: Worn or damaged parts (e.g., clamp, pressure gauge, relief valve, o-rings) should be replaced immediately to maintain system integrity and safety.
  • Pump Strainer and Skimmer Basket Cleaning: Regular cleaning is necessary for proper system operation and to prevent damage to the pump and filter.
  • Solvent Application: Care should be taken not to excessively apply solvents to fittings, as this can affect O-ring seals.
  • Fitting Tightness: Do not overtighten fittings or adapters.
  • Winterization: Allowing water to freeze in the system will cause damage and potential flooding, necessitating proper winterization procedures (though not explicitly detailed, it's implied by the warning).

Safety Features and Warnings:

  • High Pressure Warning: The filter operates under high pressure. Air in the system or an improperly clamped valve can cause the lid or control valve to separate, leading to serious injury, death, or property damage. Instructions for relieving pressure before servicing are critical.
  • Electrical Shock Hazard: Pumps require high voltage. Power must always be disconnected at the circuit breaker before servicing the pump to prevent electric shock, burns, or death.
  • Suction Entrapment Hazard: Pool and spa pumps move large volumes of water. Improperly sized drains or a person's hair coming into proximity with a drain can pose extreme danger. The manual references the Virginia Graeme Baker Pool and Spa Safety Act, outlining requirements for suction outlets, including gravity drainage systems, multiple main drain systems, safety vacuum release systems (SVRS), suction-limiting vent systems, or automatic pump shut-off systems.
  • Chemical Corrosion: Chemical fumes or spills can cause serious corrosion to filter and pump components, leading to structural weakening and potential separation of parts.
  • Child Safety: Children should not be permitted to use or operate the pump and sand filter.
  • Water Clarity: Inadequate filtration can lead to poor water clarity, obstructing visibility and increasing the risk of injury or drowning.
  • Professional Installation: A qualified pool and spa service professional should install the pump in accordance with the National Electrical Code and all applicable local codes and ordinances.
  • Unauthorized Modifications: Any modifications to the equipment require prior consent from the supplier to ensure safety. The supplier disclaims liability for damage or injuries from unauthorized parts or accessories.

Xtreme Power 75132 Specifications

General IconGeneral
BrandXtreme Power
Model75132
CategoryWater Pump
LanguageEnglish

Related product manuals