Stop And Run The Pump
Start The Pump
1)
Make sure the pump is connected with electricity. When power is on, the display screen will display
the time.
2)
Press one of ECO/CLEAN/BOOST, the pump will run. The light on the corresponding program will be
lit. No matter what program you select, the pump will run on 2850RPM for 5 minutes to eliminate the
air in the pump, so the impeller will not dry grind thus to cause leakage. After high-speed running,
the pump will run the default speed of the selected program.
Stop The Pump
Press STOP of the running pump, the pump will stop. The lights on the screen twinkle.
Change Pump Running Speed
1)
When the pump is running ECO/CLEAN/BOOST, press arrow buttons up or down to change the
speed, each press is for 50RPM. It will save automatically, no need to press ENTER.
2)
Switch ECO/CLEAN/BOOST during pump operation, the pump will not run 5 minutes high speed
again.
3)
For MODE 1 and MODE 2, to change speed of S 1 and S3, first press CLEAN, if not work, you will
need to stop the pump first. After 5 minutes high speed running, press CLEAN, then press arrow button
to increase or decrease RPM. When press MODE 1 or MODE 2 again to run the pump, S 1 and S3 will
run as just selected.
To adjust S2 and S4, first press ECO, if not work, you will need to stop the pump. After 10 minutes high
speed running, press ECO, then press arrow button to increase or decrease RPM . When press MODE
1 or MODE 2 again, S2 and S4 will run as just selected.
NOTE:
PRM for S2 and S4 or Sl and S3 are always the same.
The default for S 1 and S3 is 2400RPM, the adjustable range is 2400 to 2850RPM.
The default for S2 and S4 is 1500RPM. The adjustable range is 1000 to 2400PRM.
Pump Run Under Pre-programmed Conditions
Pump has three quick start button ECO/CLEAN/BOOST, as below image. The default speed is 1500,
2400, 3250RPM respectively.


D

1)
Be sure the pump is power on.
2)
Press one of ECO/CLEAN/BOOST,
the LED light on screen will be lit.
3)
The screen will display STUP for 1 second, and run 2850PRM
for 5 minutes. After 10 minutes, the pump will run on the
selected speed.

