SILENT STORM
VFD Pumping System
INSTRUCTION MANUAL
19-001-200R2
NOTE: This product is not intended for use in potable water applications.
INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER’S USE.

Table of Contents

Questions and Answers

  • T
    Tom DayAug 12, 2025
    What to do if my Xylem Flowtronex SILENT STORM has low discharge pressure?
    • K
      kathleensmithAug 12, 2025
      If your Xylem Water Pump has low discharge pressure, several factors could be responsible. The flow rate may be greater than the station capacity, or the system might be unable to pressurize in refill mode because too many sprinklers are active; in this case, adjust the irrigation demand as needed. It's also possible there's a large break in the irrigation piping, which would require repair. Another potential cause is low suction pressure or a supply water restriction, so it is advisable to check the supply piping for obstructions. If the water pressure from the city is lower than normal, contact them.
  • J
    John WoodsAug 16, 2025
    How to troubleshoot a Xylem Water Pump motor that won't start?
    • W
      Willie LopezAug 16, 2025
      If the individual pump switch light is flashing, it indicates that the overload for that motor has tripped. In this case, the overload should be reset, adjusted, or replaced. If the individual pump switch light is off, and the pump is in VFD mode, check if the motor runs in XL mode. If it does, refer to the VFD troubleshooting section. If the individual pump switch light is green, the pump may be jammed. Disconnect the motor from the pump and attempt to run the motor separately.
  • I
    Ian RamseyAug 20, 2025
    What causes high discharge pressure in a Xylem Flowtronex SILENT STORM and how to fix it?
    • B
      Bradley MartinezAug 20, 2025
      High discharge pressure in your Xylem Water Pump can stem from several causes. The high system pressure setting might be too low; in this case, verify that n70:0 is set to 60 seconds by pressing F1, F8, and F11. Alternatively, the system pressure transducer might be reading high; compare the display readout to the pressure gauge and calibrate if possible, replacing the transducer if necessary. Ensure that the isolation valve for the DSR or main discharge is open. If the DSR won't open fully, adjust the pilot valve as necessary, setting it 15 PSI over the set pressure.
  • S
    sherry25Aug 23, 2025
    Why does my Xylem Water Pump show a phase fault?
    • J
      josephhillAug 23, 2025
      A phase fault in your Xylem Water Pump can occur due to several reasons. A previous power failure might be the cause; try pressing the station reset to clear the fault. If the incoming line voltage is less than 90% of the rated station voltage, consult the power company. A reversal, shift, or imbalance of the line phases, often after the power company has worked on the transformer, can also cause this issue, so contacting them is recommended.
  • L
    Leslie MccormickAug 27, 2025
    How to resolve a low inlet pressure fault on my Xylem Flowtronex SILENT STORM?
    • M
      Miss Michelle GardnerAug 27, 2025
      To resolve a low inlet pressure fault on your Xylem Water Pump, first, if the water is supplied by the city, check with them if the pressure is actually low. If the water is supplied by a tank, check the tank level. Ensure that the supply piping is not clogged or restricted. Also, make sure that the flow rate is less than the supply capacity.
  • C
    Crystal WashingtonAug 30, 2025
    What does a VFD fault on my Xylem Water Pump mean?
    • T
      Timothy DickersonAug 31, 2025
      To determine the cause of a VFD fault on your Xylem Water Pump, check the VFD keypad for a specific fault code and then consult the VFD manual for troubleshooting steps. For example, fault code 3 indicates the drive heatsink is overheated and fault code 2 means that the intermediate circuit DC voltage is excessive.
  • S
    Sarah HuangSep 3, 2025
    What to do if my Xylem Water Pump shows a low level fault?
    • B
      Briana GrossSep 3, 2025
      If your Xylem Water Pump is showing a low level fault, start by checking the supply pipe for any restrictions or closed valves. Inspect the inlet screen for clogs and clean it if necessary. Also, examine the level probes to ensure they are inserted to the correct depth.
  • E
    Elizabeth BurkeSep 7, 2025
    How can I fix a loss of prime fault in my Xylem Flowtronex SILENT STORM Water Pump?
    • M
      Michelle SmithSep 7, 2025
      To address a loss of prime fault in your Xylem Water Pump, check the system for a prime leak in the foot valve or suction line. Additionally, inspect the probe for dirt, corrosion, or failure, and clean or replace it as needed.

Summary

Acknowledgements

WARRANTY INFORMATION

SAFETY

SAFETY INSTRUCTIONS

Explains the safety alert symbol and its purpose for potential injury hazards.

SAFETY REMINDERS

Lists essential safety reminders for system installation, operation, and maintenance.

GENERAL DESCRIPTION

ADDITIONAL SAFETY INFORMATION

Provides detailed safety precautions for handling, apparel, coupling guards, and operation.

Maintenance Safety

Lists specific safety precautions to be followed during maintenance activities.

PRODUCT DESCRIPTION

Describes the Flowtronex Silent Storm VFD Pumping System's features, design, and purpose.

OPERATIONAL LIMITS

Details the system's pressure limits based on different pump system types.

NAMEPLATE INFORMATION

Explains the identification and rating information found on the system's nameplate.

STATION NUMBERING

Provides the format and components for numbering pump stations.

HANDLING

Instructions for safely unloading, moving, and inspecting the pumping unit upon receipt.

STORAGE

Guidelines for storing the pumping system to prevent corrosion, contamination, and damage.

FIELD CONNECTION DIAGRAMS

Notes on reviewing specific diagrams before unit installation and operation.

GROUND CONNECTIONS

Details requirements for proper grounding connection of the system according to codes.

INSTALLATION

LOCATION

Recommended criteria for selecting a clean, well-ventilated, and properly drained location for the system.

FOUNDATION

Requirements for establishing a stable, level concrete foundation with appropriate anchor bolts.

PUMP INSTALLATION

Instructions for installing the pumps, including preparation and securing the unit.

STATION OPERATION

DOOR SWITCH OPERATION

Explains how the door switch interacts with the system control switch to select operation modes.

AUTOMATIC OPERATION

Overview

Provides an overview of the benefits and functionality of automatic operation for pressure boosting.

Line Fill Mode

Describes the procedure for line fill mode during initial startup or after line repairs.

System Charging Mode

Explains the mode where the system maintains pressure after initial fill, handling minor demands.

Normal Operation

Details the sequence for normal operation, pump staging, and pressure control.

Manual VFD Operation

Overview

Explains how to operate the system manually using the VFD and speed potentiometer.

VFD Bypass Operation, Manual mode

Overview

Describes manual bypass operation when the VFD is inoperable, relying on a PRV.

VFD Bypass Operation, Auto mode

Overview

Details automatic bypass operation when the VFD is inoperable, requiring a PRV for pressure regulation.

PLC Bypass Operation

Overview

Explains operation when the PLC is inoperable, using manual controls and safeties.

SYSTEM SAFETIES

Overview

Lists system faults, their restart capabilities, and general safety protection mechanisms.

Manual Mode of Operation

Explains how faults are cleared in manual operation by resetting or re-arming.

MAINTENANCE

REGULAR MAINTENANCE = INVESTMENT

Emphasizes the importance of routine maintenance for improving system reliability and durability.

REGULAR MONTHLY MAINTENANCE INTERVALS

Lists specific monthly maintenance tasks for heat exchangers, control panels, motors, and pumps.

WINTERIZING PUMP STATIONS

Instructions for winterizing the pumping system before storage to prevent damage from freezing.

TROUBLESHOOTING

LOW DISCHARGE PRESSURE FAULT

Lists causes and cures for faults related to low discharge pressure.

HIGH DISCHARGE PRESSURE FAULT

Lists causes and cures for faults related to high discharge pressure.

LOW LEVEL FAULT

Lists causes and cures for faults detected by low level probes in the wet well.

LOW INLET PRESSURE FAULT

Lists causes and cures for faults related to low inlet pressure, typically on flooded suction systems.

LOSS OF PRIME FAULT

Lists causes and cures for faults indicating the pump has lost its prime or has trapped air.

PHASE FAULT

Lists causes and cures for faults related to incoming voltage, phase sequence, or phase monitor failure.

VFD FAULT

Lists causes and cures for faults detected by the Variable Frequency Drive (VFD).

MOTOR WONT START

Lists causes and cures for situations where the motor fails to start.

GLOSSARY OF TERMS

APPENDIX A - FINAL CHECK LIST

APPENDIX B - ELECTRICAL WIRING AND CONTROL SETTINGS FINAL CHECKLIST

Xylem Flowtronex SILENT STORM Specifications

General IconGeneral
BrandXylem
ModelFlowtronex SILENT STORM
CategoryWater Pump
LanguageEnglish