15
Specifications
All devices
Environmental conditions
-10°C to 40°C, relative humidity 70% non-condensing for
all units except the external siren. Siren: -20°C to 50°C,
relative humidity 95% non-condensing
Radio operational range
30m in a typical domestic installation, range can vary
depending on building construction, device positions and
RF environment
Housings ABS/polycarbonate
Siren
Siren output 104dBA sound
pressure @ 1m minimum
Radio 868MHz FM
Power supply 6V, 4 x D alkaline
batteries.
PIR Motion Detector
Alarm processing Microprocessor controlled dual edge
sequential pulse count with pulse length discrimination
Radio 868MHz FM
Power supply 4.5V, 3 x AAA alkaline batteries.
Movement detection range
12 metres,110°
Door/Window Contact
Radio 868MHz FM
Power supply 3 V, CR2032 lithium coin cell battery.
Smoke Detector
Radio 868MHz FM
Power supply 4.5V, 3 x AA alkaline
batteries.
Tested to EN54
Key Fob
Radio 868MHz FM
Power supply 3 V, CR2032 lithium coin cell battery.
Key Pad
Radio 868MHz FM
Power supply3 V, CR2032 lithium coin cell battery.
Panic Button
Radio 868MHz FM
Power supply 3 V, CR2032 lithium coin cell battery.