STATUS
CODE
DISPLAY MESSAGE RECOVERY METHOD CIRCUIT
13316
(cont)
13316 Automatic RH Traction
Node 3
DESCRIPTION BEHAVIOR
Proportional lowering valve coil circuit open -
(RH Node 3)
Unable to lower forks.
Probable Causes and Test Procedures
5. Verify if controller drive at fault:
a. Measure voltage across coil while activating coil function, does voltage transition to 0V to B+?
YES- Controller not at fault, replace coil.
NO- Controller faulted, contact Service Engineering.
Troubleshooting 2200 YRM 1415
76