CAUTION
[Operating method]
- Air may leak slightly from air valve, and it will mix into the material from the inductor plate. If you do not
prefer it, please consult to YAMADA.
[Installation and piping]
- Install an emergency stop valve.
Attach an emergency stop valve to the air piping (somewhere accessible between the air source and unit)
and close this valve in case of emergency.
- Stop operation.
If any abnormality is found during operation, immediately stop the machine. Do not restart until the cause
has been identified and corrected.
- Shut off air supply.
Shut off the air source BEFORE installation and piping.
- Install properly.
Install the unit properly according to the requirements for location and material, pressure resistance, and
size of hoses and other device, avoiding lift operation failure and pipe leakage or breakage.
- Do not plumb directly.
Do not connect the material outlet and piping directly. Attach a flexible tube like a hose to connect the pump
to the piping. The pump, if connected directly to the piping, may cause many problems (e.g., noise caused
by vibration, damage to the piping, operation failure of the lift, and failure of maintenance).
[Handling]
- Do not put your hand or any other part of your body between the inductor plate and a pail.
Be aware that the lift, when operated at 0.5MPa air pressure, will generate about 270kgf (press force). Be
sure to set the lift air regulator normally at 0.4MPa and NEVER exceed the maximum operating pressure of
0.7MPa.
- Do not touch the speed control on the air cylinder of the lift.
The lift speed is maintained at a constant level (factory setting).
- In case of emergency
Close the emergency stop valve.
- Air pressure to the unit
Set the primary air pressure to 1.0MPa or less.
- Air pressure to the pump
Set the pump air regulator to 0.7MPa or less.
[Shutdown and storage]
- When left unused for a long time (an hour or more) or shutdown
In such case, close the air source and open the bleeder valve to release residual pressure inside the pump.
(Close the bleeder valve after the residual air and material is removed.)
If a drum is not mounted, move the lift to the lower limit and put a plastic bag over the inductor plate to
prevent dust.

Other manuals for YAMADA 140 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YAMADA 140 Series and is the answer not in the manual?

YAMADA 140 Series Specifications

General IconGeneral
BrandYAMADA
Model140 Series
CategoryWater Pump
LanguageEnglish

Related product manuals