Operation
62
5. Alarm
Stop the engine without fail and engage the brake pedal lock, when you remove jam.
Do not put the hand in the conveyor and the chain. It causes to injure.
When the indicator lamps or the buzzer sounds, make sure of abnormal point and take the following steps.
No Mark Name Alarm Remedy Check/maintenance
1
Charging
○
It is normal that the indicator is on after turning
the key switch to “ON” and off after the engine
starts up. Check the charging circuit if the
indicator remains lit during operation.
Tension of
engine fan
belt
2
Oil pressure
○
It is normal that the indicator is on after turning
the key switch to “ON” and off after the engine
starts up. Check oil quantity if the indicator
remains lit during operation.
Insufficient
engine oil.
Low oil
viscosity
3
Water
temperature
◎
Perform no-load operation at a low speed till
the indicator goes out, and then turn off the
engine. If the cooling liquid is insufficient, add
after the engine cools down.
Tension of fan
belt
Water leakage
Cleaning dust
on the screen
of radiator
4
Grain tank
◎
When the tank is full of grain, stop the
harvesting, and discharge grain.
5
2nd
◎
If the secondary conveyer is blocked, stop the
machine and clean completely.
Belt tension
○ means the indicator is lit; ◎ means the indicator is lit while the buzzer sounds;
○