EasyManua.ls Logo

Yatai N-6000 - User Manual

Default Icon
3 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Please read this manual thoroughly for the instruction of correct usage before using this product and keep this
manual as a reference.
l Before cleaning the controller, please ensure that the power is switch off.
l Please remove stains on the display panel by using a soft cloth only.
l No scrubbing or touching the display panel with any hard object, the display panel can be easily scratched.
l Do not press any button on the display panel using pointy objects such as ballpoint pen or screw driver, it
can easily scratch the panel or damage buttons on the panel.
Please confirm the product you received is in full agreement with the model that you selected according to the
following codes:
Panel Dimensionsmm
D:96×96 F:96×48
E:72×72 G:48×48
T ype of Display
6: Double rows display
Type of control action
0: On-off action Relay 3: Time proportion action
4: On-off PID action with auto-tuning
7: Single phase zero-across pulse PID action with auto-tuning
On -off position Alarm
0: No alarm 1: High alarm
Type of Input
1: Thermocouple signal
2: Thermo-resistance signal (RTD input)
Type of Output
No: Relay contact (Maximum 3A)
V: Logic output for SSR
A: Relay contact (Maximum 16A)
B: Relay contact (Maximum 16A)
Type of ca libration
Lower limit of the span
Upper limit of the span
2.1 Caution when installing
Please install the controller under the following conditions:
l Temperature: 0 to 50 degrees C.
l Humidity: 45% to 85% RH.
l Atmospheric pressure: 86 to 106kPa
Please avoid the following conditions during installation:
l Rapid temperature changes, leading to dew condensation.
l Corrosive gases (especially sulfide gas, ammonia, etc.) or flammable gases.
l Direct vibration or shock
l Contact with water, oil, chemicals, steam , smoke, or hot water
l High concentrations of atmospheric dust, salt or iron particles
l Large inductive interference, resulting in static electricity, magnetic fields or noise.
l Direct sunlight.
l Radiant heat sources, etc
2.2 Mounting Process
1
Cut out rectangle holes on the panel for installing the controller according to the required hole size.
When installing more than one controller, the minimum horizontal and vertical distance between two holes should be 25mm
and 30mm respectively.
2Insert the controller into the hole on the panel.
3Insert mounting bracket in the slot for mounting the controller.
4Push the mounting bracket tightly to connect the instrument and the panel firmly
2.3 Dimension in millimeters
H h
Model
H×B h×b×L h×b
ND 96×96 92×92×70 (92+1)×(92+1)
B L NE 72×72 68×68×70 (68+1)×(68+1)
b b' NF 96×48 92×44×70 (92+1)×(44+1)
NG 48×48 44×44×100 (44+1)×(44+1)
h'
31 Wiring cautions
1 For thermocouple input, use the specified compensation wire.
2 For RTD input, use leads with low resistance and having no resistance differences among the 3 leads.
3 Conduct input signal wiring away from instrument power, electric equipment power and load lines to
avoid noise induction.
32 Terminals' configuration
1Terminals for Model: 2Terminals for Model (with SSR):
ND/F/E-6011, 6311, 6411, 6012, 6312, 6412 ND/F/E-6401V, 6401V, 6302V, 6402V
Question and Answer IconNeed help?

Do you have a question about the Yatai N-6000 and is the answer not in the manual?

Summary

CAUTION WHEN OPERATING

Confirmation of the product

Installation

Caution when installing

Conditions and precautions for installing the controller to ensure proper operation and safety.

Mounting Process

Step-by-step guide for physically mounting the controller onto a panel, including hole dimensions.

Dimension in millimeters

Technical specifications detailing the physical dimensions of different controller models.

Wiring

Wiring cautions

Important considerations for input signal wiring to prevent noise induction and ensure signal integrity.

Terminals configuration

Diagrams showing terminal connections for different controller models, including SSR and thyristor types.

Operation

Sequence to pick up the functions of the instrument

Describes the operational sequence when the instrument is powered on and how it displays information.

Panel layout

Explanation of the functions and indicators on the controller's front panel display and buttons.

The detail description for every function

Detailed explanations of specific functions, including error messages and methods for changing values.

Function parameters

The function of the controller Auto-tuning

Explanation of the auto-tuning process and how it automatically sets PID parameters for optimal control.

Service and Maintenance

Information regarding product warranty, repair, and recommended storage conditions for the controller.

Yatai N-6000 Specifications

General IconGeneral
CategoryTemperature Controller
Control MethodPID, ON/OFF
Control OutputRelay, SSR
DisplayLED
Power Supply100-240VAC, 50/60Hz
Resolution0.1°C
CommunicationRS485
ModelYatai N-6000
Input TypeThermocouple, RTD, Analog

Related product manuals