Please read this manual thoroughly for the instruction of correct usage before using this product and keep this
manual as a reference.
l Before cleaning the controller, please ensure that the power is switch off.
l Please remove stains on the display panel by using a soft cloth only.
l No scrubbing or touching the display panel with any hard object, the display panel can be easily scratched.
l Do not press any button on the display panel using pointy objects such as ballpoint pen or screw driver, it
can easily scratch the panel or damage buttons on the panel.
Please confirm the product you received is in full agreement with the model that you selected according to the
following codes:
Panel Dimensionsmm
D:96×96 F:96×48
E:72×72 G:48×48
T ype of Display
6: Double rows display
Type of control action
0: On-off action Relay 3: Time proportion action
4: On-off PID action with auto-tuning
7: Single phase zero-across pulse PID action with auto-tuning
On -off position Alarm
0: No alarm 1: High alarm
Type of Input
1: Thermocouple signal
2: Thermo-resistance signal (RTD input)
Type of Output
No: Relay contact (Maximum 3A)
V: Logic output for SSR
A: Relay contact (Maximum 16A)
B: Relay contact (Maximum 16A)
Type of ca libration
Lower limit of the span
Upper limit of the span
2.1 Caution when installing
Please install the controller under the following conditions:
l Temperature: 0 to 50 degrees C.
l Humidity: 45% to 85% RH.
l Atmospheric pressure: 86 to 106kPa
Please avoid the following conditions during installation:
l Rapid temperature changes, leading to dew condensation.
l Corrosive gases (especially sulfide gas, ammonia, etc.) or flammable gases.
l Direct vibration or shock
l Contact with water, oil, chemicals, steam , smoke, or hot water
l High concentrations of atmospheric dust, salt or iron particles
l Large inductive interference, resulting in static electricity, magnetic fields or noise.
l Direct sunlight.
l Radiant heat sources, etc
2.2 Mounting Process
1
Cut out rectangle holes on the panel for installing the controller according to the required hole size.
When installing more than one controller, the minimum horizontal and vertical distance between two holes should be 25mm
and 30mm respectively.
2Insert the controller into the hole on the panel.
3Insert mounting bracket in the slot for mounting the controller.
4Push the mounting bracket tightly to connect the instrument and the panel firmly
2.3 Dimension in millimeters
H h
Model
H×B h×b×L h×b
ND 96×96 92×92×70 (92+1)×(92+1)
B L NE 72×72 68×68×70 (68+1)×(68+1)
b b' NF 96×48 92×44×70 (92+1)×(44+1)
NG 48×48 44×44×100 (44+1)×(44+1)
h'
31 Wiring cautions
1 For thermocouple input, use the specified compensation wire.
2 For RTD input, use leads with low resistance and having no resistance differences among the 3 leads.
3 Conduct input signal wiring away from instrument power, electric equipment power and load lines to
avoid noise induction.
32 Terminals' configuration
1Terminals for Model: 2Terminals for Model (with SSR):
ND/F/E-6011, 6311, 6411, 6012, 6312, 6412 ND/F/E-6401V, 6401V, 6302V, 6402V

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yatai N-6000 and is the answer not in the manual?

Yatai N-6000 Specifications

General IconGeneral
BrandYatai
ModelN-6000
CategoryTemperature Controller
LanguageEnglish

Related product manuals