EasyManua.ls Logo

Yatai AISET NTTF/H-3000 - User Manual

Yatai AISET NTTF/H-3000
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
NTTF/H-3000
Please read this manual thoroughly for the instruction of correct usage before using this product and keep this manual
as a reference.
l Before cleaning the controller, please ensure that the power is switch off.
l Please remove stains on the display panel by using a soft cloth only.
l No scrubbing or touching the display panel with any hard object, the display panel can be easily scratched.
l Do not press any button on the display panel using pointy objects such as ballpoint pen or screw driver, it can
easily scratch the panel or damage buttons on the panel.
Please confirm the product you received is in full agreement with the model that you selected according to the
following codes:
① Panel size(mm)
H:48*96 E:72*72
② Model:3
③ Control Mode
0:On-Off Control
4:On–Off PID Control (heating Type)
④ Timing Output
0: no timing output
1: Relay Output
2: Buzzer Output (internal)
3: Buzzer Output (external)
⑤ Timer Mode
0: NO timing
1: Timer Startup by a switch and display counting down
2: High and low temperature control, Timer Startup by a short current
and display counting down
3: Timer Startup with set temperature and Counting down
4: Turn switch on to start timer and the relay will be closed. When the
timer reaches the preset value, the relay will be opened.
5: Release switch to start timing, display will show remaining time,
when the timer research preset value, the relay will be closed.
6: Releasing switch to start timing, the relay will be closed, when the
time reaches the preset value, the relay will be opened.
⑥ Output Type
Omit: Relay Output
V: Logic Output (for the control of solid-state relay SSR)
G: SRC ((under 300W only)
WG: external silicon controlled rectifier
WR: external relay
⑦ Thermocouples types:
K:0-800℃;E:0-600℃;J:0-550℃
⑧ LRL
⑨ URL
2.1 Caution when installing
Please install the controller under the following conditions:
l Temperature: 0 to 50 degrees C.
l Humidity: 45% to 85% RH.
l Atmospheric pressure: 86 to 106kPa
Please avoid the following conditions during installation:
l Rapid temperature changes, leading to dew condensation.
l Corrosive gases (especially sulfide gas, ammonia, etc.) or flammable gases.
l Direct vibration or shock
l Contact with water, oil, chemicals, steam , smoke, or hot water
l High concentrations of atmospheric dust, salt or iron particles
l Large inductive interference, resulting in static electricity, magnetic fields or noise.
l Direct sunlight.
l Radiant heat sources, etc
2.2 Mounting Process
(1)Cut out rectangle holes on the panel for installing the controller according to the required hole size.
When installing more than one controller, the minimum horizontal and vertical distance between two holes should be
25mm and 30mm respectively.
(2)Insert the controller into the hole on the panel.
(3)Insert mounting bracket in the slot for mounting the controller.
(4)Push the mounting bracket tightly to connect the instrument and the panel firmly.
2.3 Panel layout
①Display (Red)
• Display the measuring temperature
②Display (Green)
• Display the set time
③Indicator
• OUT indicator for heating output (Green), Bright at working.
• SETTEM indicator (Red): Bright when setting the temperature
• AT/ALM indicator (Red), Bright at working.
• SETTIME indicator (GREEN): Bright when setting the time
④Function key
• Used to modify the setting value, calling out, modify and
confirm the parameters。
⑤ , ⑥Digital Adjustment Key
• Used to modify the setting value and the control parameters, or
for entering in the timing state.
2.4 Key Performance
1) Measurement accuracy: 0.5%±1dig 2) Power: 220VAC 3)Operation Temperature:0~50℃ 4)Fuzzy PID control
5) This product conforms with the “Q/SQG01-1999 Intelligent Digital Display Adjustor” Standard Regulation.
3.1 Attention to the wiring
(1) For thermocouple input, the corresponding compensation line should be used.
(2) Input signal lines should be far away from power supply and load lines to avoid noise interference.
3.2 Wiring Terminal’s configuration
4.1 The order of calling out the various functions
After the instrument is power on, the upper row displays InP and the lower row displays the calibration mark of the
sensor to express the input type. 4 seconds later, the upper row displays the upper limit of the measuring range and the
lower row displays the lower limit of the measuring range then the measurement range is determined. Again after 4
seconds, the upper row displays the measuring value and the lower row displays the setting value. And then the system
enters its normal working state.
2
3
4
5
11
12
136
3
4
9
10
85~264
VAC
OUT1
~
-
+
OUT2
+
-
TC
KT
NTTF/H-3000
Intelligent Temperature Controller
USER MANUAL
Question and Answer IconNeed help?

Do you have a question about the Yatai AISET NTTF/H-3000 and is the answer not in the manual?

Summary

Caution When Operating

Confirmation of the Product

Installation

Caution when installing

Safety guidelines and environmental conditions for installing the controller.

Mounting Process

Steps for physically installing the controller into a panel using brackets.

Panel layout

Identification of the display and control buttons on the controller's front panel.

Key Performance

Overview of indicators, function keys, and technical specifications of the controller.

Wiring

Attention to the wiring

Important considerations for input signal wiring to avoid noise interference.

Wiring Terminals configuration

Diagram and explanation of the controller's terminal connections for wiring.

Operation

Order of Calling Out Functions

Describes the sequence of displays and states upon powering the controller.

Setting Parameters

Details on how to set temperature, timing, and control parameters.

Service and Maintenance

Overview

The AISET NTTF/H-3000 is an intelligent temperature controller designed for precise temperature management in various industrial and commercial applications. This device offers a range of control modes, timing functions, and measurement capabilities, making it a versatile tool for process automation.

Function Description

The NTTF/H-3000 primarily functions as a temperature controller, capable of maintaining a desired temperature within a specified range. It supports both On-Off Control and Fuzzy PID Control (heating type), allowing for flexible and accurate temperature regulation. The controller features a dual display: a red display for the measured temperature and a green display for the set time or set point.

Key indicators on the panel provide visual feedback:

  • OUT indicator (Green): Illuminates when heating output is active.
  • SETTEM indicator (Red): Lights up when setting the temperature.
  • AT/ALM indicator (Red): Illuminates when active.
  • SETTIME indicator (GREEN): Lights up when setting the time.

The device incorporates various timing output options, including no timing output, relay output, and internal/external buzzer output. It supports multiple timer modes, such as:

  • No timing.
  • Timer startup via a switch with a countdown display.
  • High and low-temperature control with timer startup via a short current and countdown display.
  • Timer startup with set temperature and countdown.
  • Specific timing sequences where the relay closes/opens or alarms activate based on preset values and switch states (e.g., "Turn switch on to start timer and the relay will be closed. When the timer reaches the preset value, the relay will be opened.").

The controller allows users to set and modify various parameters, including:

  • Temperature Set Point (SP): Adjusted using the function and digital adjustment keys.
  • Timing Set Point (ST): Configured similarly to the temperature set point.
  • Control Parameters: Accessed by holding the function key for over 4 seconds, allowing adjustment of proportional band (P), integral time (I), differential time (D), overshoot restraint (Ar), and control period (T).
  • Alarm Settings (AL1): Configurable for an insensitive interval of alarm.
  • Measurement Range: Selectable by holding the function and digital adjustment keys simultaneously.
  • Temperature Scale: Switchable between Celsius (K-C) and Fahrenheit (K-F) by holding the function and digital adjustment keys simultaneously.

An Auto-tuning function (AT) is available to automatically determine optimal PID parameters. This process involves the controller undergoing one to two cycles of oscillation, after which the AT indicator extinguishes, and the updated parameters are permanently stored.

The device also includes a Process Offset (Pb) parameter for correcting measurement errors caused by the sensor or compensation line.

Important Technical Specifications

  • Measurement Accuracy: 0.5% ± 1 digit.
  • Power Supply: 220VAC (85-264VAC input range for wiring terminal).
  • Operation Temperature: 0 ~ 50°C.
  • Control Method: Fuzzy PID control.
  • Thermocouple Types Supported: K (0-800°C), E (0-600°C), J (0-550°C).
  • Panel Sizes: H: 48x96mm, E: 72x72mm.
  • Atmospheric Pressure: 86 to 106kPa.
  • Humidity: 45% to 85% RH.
  • Output Types: Relay Output, Logic Output (for SSR control), SRC (under 300W only), external silicon controlled rectifier, external relay.
  • Standard Regulation: Conforms with "Q/SQG01-1999 Intelligent Digital Display Adjustor" Standard Regulation.

Usage Features

  • Easy Parameter Adjustment: Dedicated function and digital adjustment keys facilitate intuitive modification of set points and control parameters.
  • Clear Display: Red and green LED displays provide clear visibility of measured values, set points, and timing information.
  • Status Indicators: Multiple LED indicators (OUT, SETTEM, AT/ALM, SETTIME) offer quick visual status checks.
  • Flexible Control Modes: Supports both basic On-Off control and advanced Fuzzy PID for diverse application requirements.
  • Comprehensive Timing Functions: A variety of timer modes and output options cater to complex process sequencing.
  • Auto-tuning Capability: Simplifies PID parameter setup, ensuring optimal control performance without manual tuning.
  • Sensor Error Correction: The Process Offset (Pb) parameter allows for fine-tuning to compensate for sensor inaccuracies.
  • Measurement Range Selection: Users can define the appropriate measurement range for their specific application.
  • Temperature Scale Switching: Conveniently switch between Celsius and Fahrenheit.
  • Wiring Considerations: Requires the use of corresponding compensation lines for thermocouple input and recommends keeping signal lines away from power supply and load lines to minimize noise interference.
  • Mounting: Designed for panel mounting with specific cutout dimensions and minimum spacing requirements for multiple units. Includes mounting brackets for secure installation.

Maintenance Features

  • Cleaning: The controller should be cleaned with a soft cloth only, with the power switched off. Avoid scrubbing or using pointy objects on the display panel to prevent scratches.
  • Environmental Requirements: To ensure proper functioning and longevity, the controller should be installed in an environment with:
    • Temperature: 0 to 50 degrees C.
    • Humidity: 45% to 85% RH.
    • Absence of rapid temperature changes (to prevent dew condensation).
    • Absence of corrosive gases (sulfide, ammonia, etc.) or flammable gases.
    • Absence of direct vibration or shock.
    • No contact with water, oil, chemicals, steam, smoke, or hot water.
    • Low concentrations of atmospheric dust, salt, or iron particles.
    • Minimal inductive interference, static electricity, magnetic fields, or noise.
    • No direct sunlight or radiant heat sources.
  • Warranty: The controller comes with a 12-month warranty from the date of purchase, covering malfunctions due to manufacturing defects. Damages caused by improper use are not covered under warranty but can be repaired at cost.
  • Lifetime Maintenance: The product is provided with lifetime maintenance and repair services at cost.
  • Storage: Keep the controller in a dry place with air and no corrosive gas.

Yatai AISET NTTF/H-3000 Specifications

General IconGeneral
BrandYatai
ModelAISET NTTF/H-3000
CategoryTemperature Controller
LanguageEnglish