EasyManuals Logo

YOKOGAWA 734 01 User Manual

YOKOGAWA 734 01
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
9
AC Current Measurement A
734 01
Range
Accuracy
Maximum
Input Current
Resolution
500µA
5000µA
50mA
500mA
5A
10A
0.01µA
0.1µA
0.001mA
0.01mA
0.0001A
0.001A
1.5+20 1+20
500mA
Protected by a
500mA/600V
fuse.
15A
Protected by a
15A/600V fuse.
<0.11
mV/µA
<4mV/mA
<0.1V/A
Vo ltage Drop
10 to 20Hz 20Hz to 1kHz
Crest factor: <3
AC Current Measurement A
734 02
Accuracy
Resolution
Range
1k to
5kHz
20Hz to
1kHz
10 to
20Hz
Voltage
Drop
Maximum
Input Current
0.01µA
0.1µA
0.001mA
0.01mA
0.0001A
0.001A
500µA
5000µA
50mA
500mA
5A
10A
1+20
0.75
+20
1+30
1.5+20 1+20 2+30
<0.11
mV/µA
500mA
Protected by a
500mA/600V
fuse.
15A
Protected by a
15A/600V fuse.
<4
mV/mA
<0.1
V/A
Crest factor: <3
Model 734 01/02
Accuracy
At 5 to 100% of range
Note: At 10 to 100% of range for 10A Range
Response time: 2 sec max.