EasyManua.ls Logo

York International P3LBX14F12001 User Manual

York International P3LBX14F12001
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
OIL-FIRED WARM AIR
FURNACE
P2HMX12F08001 P3HMX14F10001
P3HMX20F12001
(Upflow or Horizontal Models)
P3LBX12F08001 P3LBX14F12001
(Lowboy Models)
INTRODUCTION...............................................................2
HEAT LOSS......................................................................2
LOCATION OF UNIT ........................................................2
AIR CONDITIONING.........................................................4
COMBUSTION AIR...........................................................4
CHIMNEY VENTING.........................................................4
OIL TANK..........................................................................6
PIPING INSTALLATION ...................................................6
ELECTRICAL CONNECTIONS ........................................6
CIRCULATING AIR BLOWER..........................................7
OIL BURNER ....................................................................8
FURNACE INSTALLATION SET-UP................................9
MAINTENANCE AND SERVICE.....................................10
OPERATING INSTRUCTIONS .......................................10
TABLE A-1: BECKETT OIL BURNER SET-UP .............11
TABLE A-2: DIRECT DRIVE BLOWER SET-UP ...........11
TABLE A-3: DIRECT DRIVE BLOWER
CHARACTERISTICS ......................................................12
GENERAL DIMENSIONS – P*HMX MODELS ...............14
GENERAL DIMENSIONS – P3LBX MODELS................15
APPENDIX B: WIRING DIAGRAM.................................16
WIRING NOTES..............................................................17
R7184 DETAILED SEQUENCE OF OPERATION..........18
TABLE C-1: ST9103 DETAILED SEQUENCE OF
OPERATION...................................................................20
TABLE C-2: CAD CELL RESISTANCE ........................21
TABLE C-3: R7184 TROUBLESHOOTING...................21
TABLE C-4: SYSTEM AND GENERAL
TROUBLESHOOTING....................................................24
AIR FILTER LOCATIONS...............................................27
REPAIR PART LIST – P3HMX14F10001 &
P3HMX20F12001............................................................28
REPAIR PART LIST – P3LBX12F08001A &
P3LBX14F12001A..........................................................29
REPAIR PART LIST – P2HMX12F08001.......................30
REPLACEMENT PART CONTACT INFORMATION......31
INSTALLATION
MANUAL
CONTENTS
Read this manual completely before beginning
installation.
Important: These instructions must be kept with
the furnace for future reference.

Other manuals for York International P3LBX14F12001

Questions and Answers:

York International P3LBX14F12001 Specifications

General IconGeneral
Model NumberP3LBX14F12001
BrandYork International
CategoryFurnace
Fuel TypeGas
AFUE80%
ConfigurationUpflow/Horizontal
Input BTU120, 000 BTU/h
Heating Capacity115, 200 BTU/h

Summary

INTRODUCTION

Furnace Model Descriptions

Details specific furnace models (P*HMX and P3LBX) and their capabilities.

Compliance and Standards

Outlines adherence to CSA standards and local installation codes.

HEAT LOSS

Calculating Heat Loss Requirements

Explains the process for determining the correct furnace and firing rate based on heat loss.

LOCATION OF UNIT

Optimal Unit Placement and Clearance

Provides guidance on positioning the furnace for efficient flue connection and airflow, including clearances.

HORIZONTAL INSTALLATION

Adjusting Burner for Horizontal Mount

Details steps for rotating the oil burner assembly for horizontal furnace installation.

NON-SUSPENDED INSTALLATION

Combustible Floor Clearances

Specifies required clearances when installing the furnace on a combustible floor.

SUSPENDED INSTALLATION

Support and Sloping for Suspended Units

Guidance on supporting the furnace and maintaining a slight slope for oil drainage.

AIR CONDITIONING

Integrating Furnace with AC Systems

Instructions for connecting the furnace with air conditioning units for proper airflow.

COMBUSTION AIR

Ventilation Requirements for Combustion Air

Details necessary ventilation openings for adequate combustion air supply.

CHIMNEY VENTING

Chimney Sizing and Draft Requirements

Guidelines for proper chimney sizing and ensuring sufficient draft.

Venting Specifics for P*HMX/P3LBX Models

Provides vent sizing recommendations for specific furnace models.

DRAFT REGULATOR CONTROL

Function and Installation of Draft Regulator

Explains the role of the draft regulator in maintaining efficient furnace operation.

OIL TANK

Oil Tank Installation and Venting

Covers requirements for oil storage tank selection, installation, and venting.

PIPING INSTALLATION

Fuel Line Standards and Lengths

Details codes, practices, and allowable lengths for oil fuel lines.

ELECTRICAL CONNECTIONS

Wiring Standards and Dedicated Circuits

Outlines wiring standards and recommends a dedicated circuit for furnace installation.

CIRCULATING AIR BLOWER

Direct Drive Blower System

Describes the direct drive blower system and its speed adjustment capabilities.

Blower Speed Adjustment Precautions

Warns against moving the neutral wire when adjusting blower speed.

Fan Operation Timing

Details the timed start-up and shut-down sequences for the circulating fan.

OIL BURNER

Burner Alignment and Firepot Checks

Emphasizes checking burner alignment with the combustion chamber before operation.

OIL BURNER NOZZLES

Selecting Nozzles for Firing Rates

Lists recommended oil burner nozzles for various furnace BTU/Hr. output ranges.

BURNER ELECTRODES

Electrode Positioning for Optimal Ignition

Specifies the correct gap and positioning for burner electrodes.

OIL BURNER SET-UP

Air Supply Adjustment and Test Port Prep

Guidance on adjusting air supply and preparing test ports for flue gas analysis.

STACK TEMPERATURE

Factors Affecting Stack Temperature and Adjustments

Explains influences on stack temp and how to adjust blower speed accordingly.

FURNACE INSTALLATION SET-UP

Temperature Rise Measurement and High Limit Test

Details temperature rise measurement and testing the high limit control.

MAINTENANCE AND SERVICE

Homeowner vs. Contractor Maintenance

Distinguishes routine homeowner tasks from annual contractor servicing.

OPERATING INSTRUCTIONS

Lighting, Shutdown, and Safety Precautions

Instructions for safe operation, including pre-lighting and shutdown procedures.

GENERAL DIMENSIONS – P*HMX MODELS

Cabinet and Overall Dimensions (P*HMX)

Details cabinet width, depth, and height for P*HMX models.

Plenum and Flue Opening Specs (P*HMX)

Specifies supply air, return air, and flue opening sizes for P*HMX models.

Filter and Ship Weight (P*HMX)

Provides filter size and shipping weight for P*HMX models.

GENERAL DIMENSIONS – P3LBX MODELS

Cabinet and Overall Dimensions (P3LBX)

Details cabinet width, length, and height for P3LBX models.

Plenum and Flue Opening Specs (P3LBX)

Specifies supply air, return air, and flue opening sizes for P3LBX models.

Filter and Ship Weight (P3LBX)

Provides filter size and shipping weight for P3LBX models.

APPENDIX B: WIRING DIAGRAM

Wiring Diagram Legend and Key Components

Explains symbols and identifies key components in the wiring diagrams.

Thermostat, Fan, and Burner Wiring

Illustrates wiring for thermostats, fan controls, and the oil burner system.

WIRING NOTES

Continuous Fan Operation and Accessory Power

Setup for continuous fan and power connections for accessories like EAC.

THERMOSTAT HEATING CONNECTIONS

Connecting Thermostat to Control Board Terminals

Specifies terminals for thermostat wiring on the ST9103 EFT control board.

R7184 Detailed Sequence of Operation

Ignition Trial, Flame Monitoring, and Carryover

Details ignition trial, flame sensing, and the carryover state of the R7184 control.

Lockout, Recycle, and Shutdown Conditions

Explains fault conditions, recycle states, and normal shutdown procedures.

R7184 SEQUENCE of OPERATION

Operational States: Idle, Trial, Carryover, Run

Describes the primary operational states of the R7184 control system.

Fault States: Lockout and Recycle

Explains the lockout and recycle states and their triggers.

R7184 LED Diagnostic Light

Interpreting Normal and Fault LED Indicators

Explains the meaning of LED indicators for operational status and fault conditions.

Troubleshooting

Preliminary Checks and R7184 Faults

Initial diagnostic steps and troubleshooting specific to R7184 control faults.

Burner Motor Start Failures

Steps to diagnose and resolve issues where the burner motor does not start.

System and General Troubleshooting

Furnace Failure to Start or Intermittent Lockouts

Diagnosing why the furnace fails to start or experiences frequent lockouts.

Oil Primary Control and Fuel Delivery Issues

Troubleshooting faulty oil primary controls and fuel delivery problems.

Air Filter Locations

Locating Air Filters in P3LBX and P*HMX Models

Visual guides to identifying the air filter placement for different furnace series.

REPAIR PART LIST – P3HMX14F10001 & P3HMX20F12001

P*HMX Series Component Diagram and Parts List

Exploded view and list of replacement parts for P*HMX furnaces.

REPAIR PART LIST – P3LBX12F08001A & P3LBX14F12001A

P3LBX Series Component Diagram and Parts List

Exploded view and list of replacement parts for P3LBX furnaces.

REPAIR PART LIST – P2HMX12F08001

P2HMX12F08001 Component Diagram and Parts List

Exploded view and list of replacement parts for the P2HMX12F08001 furnace.

REPLACEMENT PART CONTACT INFORMATION

Contacting York International for Parts

Provides contact methods (phone, web, mail) for obtaining replacement parts.

NOTES

Related product manuals