SPLIT-SYSTEM AIR CONDITIONERS
10 SEER 50 H
Z
H*RA018S78 THRU H*RA036S78 (1 PH)
H*RA036S50 THRU H*RA060S50 (3PH)
(1.5 THRU 5 NOMINAL TONS)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
DESCRIPTION
The HRA Series condensing unit is the outdoor part of a ver-
satile system of air conditioning. It is designed to be custom
matched with one of UPG’s complete line of evaporator sec-
tions, each designed to serve a specific function. Matching
Air Handlers are available for upflow, downflow or horizontal
applications to provide a complete system. Electric Heaters
are available if required. Add-On coils are available for use
with upflow, downflow or horizontal furnaces and air handlers.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed
of enhanced copper tube and aluminum fins.
COIL PROTECTION - Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
DURABLE FINISH - Cabinet is made of pre-painted steel.
The pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connections.
Discharge line heat exchanger knockouts are provided, if
required. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimen-
sion means less space is required on the ground or roof.
TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins of
the condenser coil muffle the normal fan motor and com-
pressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, a single panel covering the electrical controls
and the molex plug in the control box connecting the con-
denser fan, make for easy servicing of the unit.
SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
FACTORY TESTED - to verify system operation and con-
trol functioning before shipment.
Question and Answer IconNeed help?

Do you have a question about the York 036-21103-003 and is the answer not in the manual?

Summary

Split-System Air Conditioner Specifications

Product Details and Model Series

Details the 'Split-System Air Conditioners' product line with 10 SEER, 50 Hz rating, model number ranges, and tonnage.

HRA Series Condensing Unit Features

Key Unit Attributes

Highlights features like coil quality, compressor protection, durable finish, and ease of installation/service.

Physical and Electrical Data

Unit Specifications and Dimensions

Presents physical dimensions, electrical ratings, and component specifications for 1 & 3 phase units.

Cooling Capacity and Performance

Air Handler Coil Matching Data

Lists cooling capacities, SEER, EER, and KW ratings for units matched with specific air handler coils.

Installation and Operation Details

Accessories, Sound Ratings, and Wiring

Covers available accessories, sound ratings, typical installation diagrams, and field wiring information.

Field Wiring Diagrams

1 Phase and 3 Phase Connections

Illustrates typical field wiring for 1-phase and 3-phase applications, including control and power wiring.

Overview

The HRA Series condensing unit is the outdoor component of a versatile split-system air conditioning system. It is designed to be custom-matched with a range of Upflow, Downflow, or Horizontal evaporator sections from UPG's product line, each tailored for a specific function. Matching air handlers are available for various applications, and electric heaters can be added if required. Add-on coils are also available for use with Upflow, Downflow, or Horizontal furnaces and air handlers.

Technical Specifications:

The HRA Series includes split-system air conditioners with 10 SEER (Seasonal Energy Efficiency Ratio) and 50 Hz operation.

  • 1 Phase Models: HRA018S78 through HRA036S78 (1.5 to 3 nominal tons).
  • 3 Phase Models: HRA036S50 through HRA060S50 (3 to 5 nominal tons).

Electrical Data (1 & 3 Phase):

  • Unit Supply Voltage: 230-1-50 for 1-phase models; 380/415-3-50 for 3-phase models.
  • Normal Voltage Range: 207 to 253 for 1-phase; 342 to 455 for 3-phase.
  • Minimum Circuit Ampacity: Ranges from 9.8 (H1RA018S78) to 20.8 (H1RA036S78) for 1-phase; 7.3 (H1RA036S50) to 13.3 (H1RA060S50) for 3-phase.
  • Max. Overcurrent Device Amps: Ranges from 15 to 35 for 1-phase; 15 to 20 for 3-phase.
  • Compressor Type: All models use Reciprocating compressors.
  • Compressor Amps (Rated Load): Ranges from 7.4 to 15.5 for 1-phase; 5.2 to 9.2 for 3-phase.
  • Compressor Amps (Locked Rotor): Ranges from 53 to 90 for 1-phase; 39 to 79 for 3-phase.
  • Crankcase Heater: Not included in any model.
  • Fan Motor Amps (Rated Load): Ranges from 0.5 to 1.8.
  • Fan Diameter: 18 inches for smaller units, 22 inches for larger 3-phase units.
  • Fan Motor Rated HP: 1/12 to 1/4 for 1-phase; 1/4 to 1/3 for 3-phase.
  • Fan Motor Nominal RPM: 970 to 900 for 1-phase; 1,100 to 1,075 for 3-phase.
  • Fan Motor Nominal CFM: 1,650 to 2,350 for 1-phase; 2,250 to 3,300 for 3-phase.
  • Face Area Sq. Ft.: 8.00 to 9.15 for 1-phase; 9.15 to 23.58 for 3-phase.
  • Coil Rows Deep: 1 for all models.
  • Fin/Inches: 14 to 16 for 1-phase; 18 for 3-phase.
  • Liquid Line OD: 3/8 inch for all models.
  • Vapor Line OD: 3/4 inch for 1-phase; 3/4 to 7/8 inch for 3-phase.
  • Unit Charge (Lbs. - Oz.): Ranges from 3-13 to 4-11 for 1-phase; 4-11 to 9-12 for 3-phase.
  • Charge Per Foot (Oz.): 0.66 to 0.68 for 1-phase; 0.68 to 0.70 for 3-phase.
  • Operating Weight (Lbs.): 118 to 137 for 1-phase; 137 to 228 for 3-phase.

Usage Features:

  • Quality Condenser Coils: Constructed with enhanced copper tubes and aluminum fins for efficient heat transfer.
  • Coil Protection: A polymer mesh is applied between the coil face and a PVC-coated steel coil guard to protect against damage.
  • Protected Compressor: The compressor is internally protected against high pressure and temperature through a high-pressure relief valve and a temperature sensor. A liquid line filter-drier provides additional protection.
  • Durable Finish: The cabinet is made of pre-painted steel with a pre-treated flat galvanized steel base for superior paint adhesion, corrosion, and rust resistance. Special primer formulas and a matted-textured finish ensure less fading from sun exposure.
  • Lower Installed Cost: Easy power and control wiring connections reduce installation time and costs. Discharge line heat exchanger knockouts are provided (if required, for sweat connect models only). The unit comes pre-charged with enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. Its compact base dimensions require less space for installation.
  • Top Discharge: The fan is top-mounted, blowing warm air upwards and away from the structure and landscaping, allowing for compact multi-unit applications.
  • Low Operating Sound Level: Upward air flow carries normal operating noise away from living areas. A rigid top panel isolates motor sound, and isolator-mounted compressor and rippled condenser coil fins muffle fan motor and compressor operating sounds.
  • Easy Service Access: Fully exposed refrigerant connections, a single panel covering electrical controls, and a Molex plug connecting the condenser fan simplify servicing.
  • Secured Service Valves: Re-usable service valves are provided on both liquid and vapor sweat connections for easy evacuation and charging.
  • Factory Tested: Each unit is factory tested to verify system operation and control functioning before shipment.

Maintenance Features:

  • Low Maintenance: Permanently lubricated motor-bearings eliminate the need for annual servicing.

Accessories:

  • Compressor Blanket: Designed to further reduce normal operating sound.
  • Hard Start Kit (Single Phase Units): Provides the necessary starting torque for units using a thermal expansion valve.
  • Outdoor Thermostat (2TD06700124): Consists of an adjustable outdoor thermostat and relay in a vented enclosure. It provides additional second-stage control of supplemental resistance heat (Balance Point Control).

York 036-21103-003 Specifications

General IconGeneral
BrandYork
Model036-21103-003
CategoryAir Conditioner
LanguageEnglish

Related product manuals