SPLIT-SYSTEM
AIR CONDITIONERS
12 SEER
MODELS:
AC018X12* THRU 060
(1.5 THRU 5 NOMINAL TONS, 1 PH)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ariprimenet.org.
LISTED
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE
SYSTEM IS LISTED
WITH ARI.
ISO 9001
Certified Quality
Management System
R
N
E
M
P
I
U
Q
E
T
Y
R
A
T
I
N
U
0
1
2
A
R
I
R
A
D
N
A
T
S
D
I
S
N
O
T
C
E
S
F
O
C
C
I
F
I
T
R
E
N
O
I
T
A
H
T
I
W
C
G
N
I
Y
L
P
M
O
S
A
I
R
A
O
T
D
E
I
F
I
T
R
E
C
R
E
R
U
T
C
A
F
U
N
A
M
C
-
G
N
I
N
O
I
T
I
D
N
O
R
I
A
036-21106-005 Rev. B (0505)
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
TECHNICAL
GUIDE
TECHNICAL
GUIDE
DESCRIPTION
The 12 SEER Series condensing unit is the outdoor
part of a versatile system of air conditioning. It is
designed to be custom-matched with one of UPG’s
complete line of evaporator sections, each designed to
serve a specific function. Matching Air Handlers are
available for upflow, downflow or horizontal applica-
tions to provide a complete system. Electric Heaters
are available if required. Add-On coils are available for
use with upflow, downflow or horizontal furnaces and
air handlers.
WARRANTY
5-year limited parts warranty.
10-year limited compressor warranty.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed
of enhanced copper tube and aluminum fins.
COIL PROTECTION - Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted textured champagne
finish insure less fading when exposed to sunlight.
LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Discharge line heat exchanger knockouts are pro-
vided, if required. Available in sweat connect models only.
The unit contains enough refrigerant for matching indoor
coils and 15 feet of interconnecting piping. The small base
dimension means less space is required on the ground or
roof.
TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, a single panel covering the electrical controls
and the molex plug in the control box connecting the con-
denser fan, make for easy servicing of the unit.
SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
Question and Answer IconNeed help?

Do you have a question about the York AC024X1222 and is the answer not in the manual?

York AC024X1222 Specifications

General IconGeneral
BrandYork
ModelAC024X1222
CategoryAir Conditioner
LanguageEnglish

Summary

Product Description and Features

Product Description

Overview of the 12 SEER Series condensing unit and system components.

Warranty Terms

Details limited parts and compressor warranties for the units.

Condenser Coil Construction

Describes the construction of enhanced copper tube and aluminum fins.

Coil Damage Protection

Details protection against damage via polymer mesh and PVC coated steel guard.

Protected Compressor

Explains internal protection against high pressure/temperature and liquid line filter-drier.

Cabinet Durability and Finish

Describes the pre-painted steel cabinet's corrosion resistance and finish.

Installation Cost Benefits

Highlights ease of wiring, compact base dimensions, and refrigerant charge.

Top Discharge Airflow Design

Explains the upward air flow from the top-mounted fan.

Reduced Operating Sound Level

Discusses how upward airflow and design features reduce operating noise.

Low Maintenance Requirements

Mentions permanently lubricated motor-bearings needing no annual servicing.

Service Accessibility

Details accessible refrigerant connections and control panels for servicing.

Secured Service Valves

Notes reusable service valves on liquid and vapor connections.

Certifications and Listings

Confirms listing for outdoor application and ARI Standard 210/240 certification.

Physical and Electrical Specifications

Unit Supply Voltage

Specifies the voltage range for the units.

Electrical Data Summary

Includes ampacity, overcurrent devices, compressor/fan motor specs.

Coil and Refrigerant Specifications

Details coil dimensions, line sizes, and refrigerant charge.

Unit Weight and Dimensions

Provides operating weight and physical dimensions of the unit.

Cooling Capacity with Air Handler Coils

Electric Heat Capacity (KW)

Details the electric heat kilowatt ratings for various configurations.

Indoor Coil Model Compatibility

Lists the indoor coil models used for performance data.

Rated Airflow (CFM)

Specifies the rated airflow in cubic feet per minute.

Cooling Capacity Metrics (MBH)

Presents the total and sensible cooling capacity in MBH.

Energy Efficiency Ratings (SEER/EER)

Details Seasonal and Energy Efficiency Ratios.

Cooling Capacity with Furnace and Coil Systems

Furnace Wattage (W)

Indicates the wattage of the furnace for matching.

Coil Model for Furnace Systems

Lists the indoor coil models used in furnace applications.

Rated Airflow for Furnace Systems (CFM)

Specifies the rated airflow in cubic feet per minute.

Cooling Capacity Metrics (Net MBH)

Presents the total and sensible cooling capacity in Net MBH.

Energy Efficiency Ratings (SEER/EER)

Details Seasonal and Energy Efficiency Ratios.

Cooling Performance Data Tables

Operating Conditions

Specifies suction pressure and condensing air temperatures.

Performance at 75°F Condensing Temp

Details cooling capacity and power consumption at 75°F.

Performance at 95°F Condensing Temp

Details cooling capacity and power consumption at 95°F.

Performance at 115°F Condensing Temp

Details cooling capacity and power consumption at 115°F.

Optional Accessories and Features

Hard Start Kit Functionality

Provides increased starting torque for low voltage conditions.

Compressor Sound Reduction

Reduces compressor operating sound.

Anti-Short Cycle Timer

Prevents rapid recycling of the compressor.

Thermostat Compatibility

Lists compatible thermostats for optimum performance.

Sound Power Level Ratings

Unit Model Identification

Lists the unit models for sound power rating.

Sound Level Measurement (dBA)

Specifies the sound power level in decibels (A-weighted).

Installation Site Requirements

Clearance Requirements

Specifies required overhead, service, and coil area clearances.

Outdoor Wiring Protection

Emphasizes that all outdoor wiring must be weatherproof.

Sealing Wall Penetrations

Recommends sealing openings with Permagum or equivalent.

Field Wiring Diagrams (1 Phase)

Power Supply Connections

Details the power wiring connections (208/230-1-60).

Low Voltage Control Wiring

Specifies the 24-volt control wiring requirements.

Contactor Terminal Connections

Identifies terminals for contactor connections.

Furnace/Air Handler Terminal Block

Wiring points on the furnace or air handler terminal block.

Room Thermostat Wiring Scheme

Diagrams thermostat wiring connections (Y, R, G, W).

Cooling Performance Data - AC018X1222

Condensing Temperature Conditions

Specifies the condensing unit's entering air temperature for performance.

Indoor Coil Model and Airflow (IDCFM)

Lists indoor coil models and their rated airflow (IDCFM).

Indoor Air Conditions (DB/WB)

Shows indoor Dry Bulb and Wet Bulb temperatures in Fahrenheit.

Total Cooling (T.C.) and Sensible Cooling (S.C.)

Presents total and sensible cooling capacities in thousands of BTU per hour.

Power Consumption (KW)

Details power consumption in kilowatts.

Cooling Performance Data - AC24X1222

Condensing Temperature Conditions

Specifies the condensing unit's entering air temperature for performance.

Indoor Coil Model and Airflow (IDCFM)

Lists indoor coil models and their rated airflow (IDCFM).

Indoor Air Conditions (DB/WB)

Shows indoor Dry Bulb and Wet Bulb temperatures in Fahrenheit.

Total Cooling (T.C.) and Sensible Cooling (S.C.)

Presents total and sensible cooling capacities in thousands of BTU per hour.

Power Consumption (KW)

Details power consumption in kilowatts.

Cooling Performance Data - AC30X1222

Condensing Temperature Conditions

Specifies the condensing unit's entering air temperature for performance.

Indoor Coil Model and Airflow (IDCFM)

Lists indoor coil models and their rated airflow (IDCFM).

Indoor Air Conditions (DB/WB)

Shows indoor Dry Bulb and Wet Bulb temperatures in Fahrenheit.

Total Cooling (T.C.) and Sensible Cooling (S.C.)

Presents total and sensible cooling capacities in thousands of BTU per hour.

Power Consumption (KW)

Details power consumption in kilowatts.

Cooling Performance Data - AC036X1222

Condensing Temperature Conditions

Specifies the condensing unit's entering air temperature for performance.

Indoor Coil Model and Airflow (IDCFM)

Lists indoor coil models and their rated airflow (IDCFM).

Indoor Air Conditions (DB/WB)

Shows indoor Dry Bulb and Wet Bulb temperatures in Fahrenheit.

Total Cooling (T.C.) and Sensible Cooling (S.C.)

Presents total and sensible cooling capacities in thousands of BTU per hour.

Power Consumption (KW)

Details power consumption in kilowatts.

Cooling Performance Data - AC042X1221

Condensing Temperature Conditions

Specifies the condensing unit's entering air temperature for performance.

Indoor Coil Model and Airflow (IDCFM)

Lists indoor coil models and their rated airflow (IDCFM).

Indoor Air Conditions (DB/WB)

Shows indoor Dry Bulb and Wet Bulb temperatures in Fahrenheit.

Total Cooling (T.C.) and Sensible Cooling (S.C.)

Presents total and sensible cooling capacities in thousands of BTU per hour.

Power Consumption (KW)

Details power consumption in kilowatts.

Cooling Performance Data - AC048X1222

Condensing Temperature Conditions

Specifies the condensing unit's entering air temperature for performance.

Indoor Coil Model and Airflow (IDCFM)

Lists indoor coil models and their rated airflow (IDCFM).

Indoor Air Conditions (DB/WB)

Shows indoor Dry Bulb and Wet Bulb temperatures in Fahrenheit.

Total Cooling (T.C.) and Sensible Cooling (S.C.)

Presents total and sensible cooling capacities in thousands of BTU per hour.

Power Consumption (KW)

Details power consumption in kilowatts.

Cooling Performance Data - AC060X1224

Condensing Temperature Conditions

Specifies the condensing unit's entering air temperature for performance.

Indoor Coil Model and Airflow (IDCFM)

Lists indoor coil models and their rated airflow (IDCFM).

Indoor Air Conditions (DB/WB)

Shows indoor Dry Bulb and Wet Bulb temperatures in Fahrenheit.

Total Cooling (T.C.) and Sensible Cooling (S.C.)

Presents total and sensible cooling capacities in thousands of BTU per hour.

Power Consumption (KW)

Details power consumption in kilowatts.

Indoor Component Matching Guide

Add-On Coils for Furnace Applications

Illustrates add-on coils for furnace applications.

Air Handlers for Non-Furnace Use

Shows air handlers for non-furnace applications.