TECHNICAL GUIDE
SINGLE PIECE VARIABLE SPEED ECM
COMMUNICATING AIR HANDLERS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: AVC SERIES
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at:
www.upgnet.com and www.york.com
A
dditional rating information can be found at:
www.ahridirectory.org
WARRANTY SUMMARY
Standard 5-year limited parts warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replacement
or closing for new home construction.
®
®
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
5151060-YTG-F-1116
DESCRIPTION
This fan coil line offers the ultimate in application flexibility. This
unit may be used for upflow, downflow, horizontal right, or
horizontal left applications.
All JCI Unitary Products air handlers and coils can use a TXV to
provide our customers with the optimum performance and
refrigerant control. Single piece air handlers are available with
“Flex-coils” (without a factory installed metering device). For
added flexibility, an R-22 or R-410A TXV or piston must be field
installed to meet the requirement of the desired refrigerant.
Some coil models available with factory installed TXV.
FEATURES
RC
2
- Rigid Case Construction interior endoskeleton for
structural support, smooth side, and locks in insulation.
Powder-painted - G30 galvanized steel case provide a coated
edge that resists corrosion and rust creep.
MaxAlloy
TM
Coil - Long life aluminum coils built to deliver
lasting performance, efficiency and reliability.
Quality Construction - Structural components are made of
Aluminum or G90 galvanized steel to prevent corrosion.
Improved Insulation Design - Single piece with no external
screws to reduce thermal transmission paths to prevent
sweating. Foil faced insulation for ease of cleaning.
Thermostatic Expansion Valve - The accessory chatleff style
TXV provides easy installation to convert the indoor coil to the
required refrigerant that does not require brazing to replace or
install. Some models are available with factory installed TXV.
Case Depth - These models have 20.5” casing which provide
ease of attic access and tight applications.
Thermoset Drain Pan - Low retention and positive slope for
drainage to reduce potential mold or contaminants.
Factory Sealed - Achieves 2% or less total airflow leakage rate
at duct leakage test conditions in positive and negative
pressure for system airflow verification.
Enhanced Filter Rack - All models have integrated internal
filter racks provided for use with 1” thick standard size filters.
Electric Heat Kits - 6HK series of field installed electric heat
kits are available for installation-friendly and easy service
applications.
Blowers - All models use direct-drive, variable speed ECM
motors.
Question and Answer IconNeed help?

Do you have a question about the York AVC36BX21 and is the answer not in the manual?

York AVC36BX21 Specifications

General IconGeneral
Model NumberAVC36BX21
CategoryAir Handlers
Cooling Capacity3 Tons
Airflow1200 CFM
Voltage208/230V
Phase1
Motor TypePSC
Length21 inches
InsulationFoil-faced

Summary

Key Product Features

MaxAlloyTM Coil

Long life aluminum coils designed for lasting performance, efficiency, and reliability.

Variable Speed ECM Blowers

All models use direct-drive, variable speed ECM motors.

Product Nomenclature and Specifications

Unit Dimensions and Duct Connections

Cooling Capacity Performance Data

Capacity vs. Entering Air Conditions

Tables showing MBH capacity at various entering air conditions and pressures.

Physical and Electrical Data (Cooling Only)

Electrical Data (Cooling Only)

Details motor FLA, minimum circuit ampacity, and MOP for cooling only.

Electric Heat Performance Data

Heat Performance by Voltage and Staging

Details kW, MBH, and staging for 1-phase and 3-phase electric heat kits.

Single Source Electrical Data (208/230-1-60)

Heater Amps and Circuit Ampacity

Provides heater amps and minimum circuit ampacity for various models and voltages.

Maximum Overcurrent Protection (MOP)

Lists MOP values for single source power supply configurations.

Single Source Electrical Data (Continued)

Extended Single Source Ampacity and MOP

Continues electrical data for larger models, including ampacity and MOP.

Multi-Source Electrical Data (208/230-1-60)

Multi-Source Ampacity and MOP Values

Details minimum circuit ampacity and MOP for multi-source power configurations.

Single Source Electrical Data (208/230-3-60)

3-Phase Single Source Ampacity and MOP

Provides ampacity and MOP for 3-phase single source power supplies.

Multi-Source Electrical Data (208/230-3-60)

3-Phase Multi-Source Ampacity and MOP

Details ampacity and MOP for 3-phase multi-source power supplies.

Power Wiring and Line Connections

Typical Thermostat Connections

Cooling Models Thermostat Wiring

Wiring diagrams for cooling-only and cooling with electric heat applications.

Two-Stage Heat Pump Thermostat Wiring

Wiring diagrams for two-stage heat pump systems.

Communicating System Wiring

Wiring diagrams for communicating AC or HP systems.

Airflow Data (CFM)

Cooling and Heat Pump Airflow

Tables showing high/low speed cooling and heat pump airflow for various models.