036-21001-005 Rev. C (0505)
22 Unitary Products Group
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. DRCS0601BF,
INDOOR COIL MODEL NO. G1FA060S21,24
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM 1600 1800 2000
ID DB (°F) 70 75 80 85 70 75 80 85 70 75 80 85
ID WB (°F) 57 63 67 72 57 63 67 72 57 63 67 72
65
T.C. 53.8 59.2 63.5 68.4 54.8 60.2 64.5 69.5 55.2 60.7 64.9 70.1
S.C. 45.6 42.7 44.1 43.6 47.9 45.3 46.6 46.2 49.4 46.9 48.4 47.9
KW 13.8 14.9 15.8 16.9 13.7 14.9 15.7 16.8 13.6 14.7 15.6 16.6
75
T.C. 51.6 56.8 60.9 65.7 52.5 57.7 61.8 66.6 53.0 58.2 62.2 67.1
S.C. 44.4 41.7 43.1 42.7 46.7 44.2 45.5 45.1 48.3 45.7 47.2 46.8
KW 11.8 12.7 13.5 14.4 11.7 12.7 13.5 14.4 11.6 12.6 13.3 14.2
85
T.C. 49.5 54.7 58.6 63.2 50.3 55.5 59.3 64.1 50.8 55.9 59.8 64.5
S.C. 43.2 41.0 42.0 41.8 45.5 43.2 44.5 44.2 47.1 44.7 46.3 45.8
KW 10.3 11.2 11.8 12.6 10.2 11.1 11.8 12.6 10.2 11.0 11.7 12.5
95
T.C. 47.2 52.2 55.8 60.3 47.9 52.8 56.5 60.9 48.4 53.3 56.8 61.2
S.C. 42.1 39.8 41.2 40.9 44.2 41.9 43.4 43.1 46.0 43.4 44.7 44.4
KW 8.8 9.6 10.2 10.9 8.8 9.5 10.1 10.8 8.8 9.5 10.0 10.7
105
T.C. 44.7 49.4 52.9 57.1 45.4 50.0 53.4 57.6 45.7 50.4 53.7 57.9
S.C. 40.6 38.6 39.8 39.6 43.1 40.6 41.9 41.6 44.6 42.4 43.5 43.2
KW 7.5 8.1 8.6 9.3 7.5 8.1 8.6 9.2 7.4 8.1 8.5 9.1
115
T.C. 42.3 46.7 50.1 53.9 42.9 47.4 50.4 54.4 43.4 47.8 50.9 54.6
S.C. 39.4 37.5 38.8 38.2 41.8 39.7 40.6 40.4 43.3 41.2 42.6 42.1
KW 6.3 6.9 7.3 7.8 6.3 6.9 7.3 7.8 6.3 6.9 7.3 7.7
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler Coil
T.C. S.C. KW
F3FP060 0.99 0.97 1.00
F3FV060 0.99 0.97 0.97
N1VSD20 G2FD060(S,H)24(T) 0.99 0.97 0.98
N1VSD20 G2FD061H24 1.00 0.98 0.97
N1AHD20 G2FD060(S,H)24(T) 1.00 1.00 1.00
N1AHD20 G2FD061H24 1.00 1.01 1.00
G1FA/G1UA060S21(T) 1.00 1.00 1.00
G2FD060(S,H)24(T) 1.00 1.00 1.00
G2FD061H24 1.00 1.01 1.00
G1NA060S24T 0.98 0.97 0.99
G1HD060 0.98 0.99 0.99
G1HA60S24(T) 0.99 0.98 0.99
Variable Speed
Furnace
Coil
T.C. S.C. KW
(G,L)8V***20UHD G1FA/G1UA060S21(T) 0.99 0.99 0.98
(G,L)8V***20UHD G2FD060(S,H)24(T) 0.99 0.99 0.98
(G,L)8V***20UHD G2FD061H24 1.00 1.00 0.98
G9V***20UPC G1FA/G1UA060S21(T) 0.99 0.96 0.99
G9V***20UPC G2FD060(S,H)24(T) 0.99 0.96 0.99
G9V***20UPC G2FD061H24 1.00 0.97 0.99
G9V***20UPD G1FA/G1UA060S24(T) 0.99 0.96 0.97
G9V***20UPD G2FD060(S,H)24(T) 0.99 0.96 0.97
G9V***20UPD G2FD061H24 1.00 0.97 0.97
G9V***20DHC G2FD060(S,H)24(T) 0.98 0.94 0.97
G9V***20DHC G2FD061H24 0.99 0.94 0.98
G9V***20DHC G1HA60H24(T) 0.98 0.94 0.97
G9V***20DHC G1HD060 0.97 0.93 0.97
G9V***20DHD G2FD060(S,H)24(T) 0.99 0.95 0.98
G9V***20DHD G2FD061H24 0.99 0.96 0.97
G9V***20UHD G1HA60H24(T) 0.99 0.95 0.98
G9V***20UHD G1HD060 0.98 0.95 0.99
(F,L)C8V***C20UH G1FA/G1UA060S21(T) 1.00 1.00 1.00
(F,L)C8V***C20UH G2FD060(S,H)24(T) 1.00 1.00 1.00
(F,L)C8V***C20UH G2FD061H24 1.01 1.01 1.00