Technical specifications
Model EVJC
Outdoor unit 09 12 18 24
Capacities
Cooling kW 2.5 (1.2 ~ 3.1) 3.5 (1.2 ~ 3.8) 5.3 (1.3 ~ 6.2) 6.4 (1.4 ~ 6.8)
Heating kW 2.8 (1.2 ~ 3.8) 4.0 (1.3 ~ 4.7) 5.8 (1.3 ~ 6.3) 7.0 (1.3 ~ 8.0)
Compressor Rotary
Refrigerant R-410A
Expansion/location Capillary/outdoor unit
Power supply V.ph.Hz 230.1.50
Consumption Cooling / Heating kW 0.74 / 0.75 1.06 / 1.10 1.60 / 1.62 1.98 / 1.93
Outdoor noise level (1 m.) dB (A) 51 52 53 54
Outer dia. condensed water drain pipe mm 16,5
Nett Weight kg 35 36 47 50
Type of connection Flared + Nut
Tubing
Gas diameter 3/8" 1/2" 1/2" 1/2”
Liquid diameter 1/4” 1/4" 1/4" 1/4”
Maximum tubing length m 15 20 25 25
Maximum elevation tubing m 5 10 10 10
Refrigerant load g 800 1 150 1 100 1 400
Nominal cooling capacity is based on: Indoor air temp. = 27°C DB/19°C WB. Outdoor air temp. = 35°C DB, 4-meter tubing.