571921-UTG-A-0410
Johnson Controls Unitary Products 17
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
GHGD42S41S4
(T*(8,L)C/T*8V)*C20 UC60C 39.5 3.88 2.98 22.2 2.62 2.48 8.20
Y*9C*C16 UC60C 40.0 3.74 3.13 22.8 2.52 2.65 8.20
Y*9C*C20 UC60C 40.0 3.78 3.10 22.6 2.54 2.61 8.20
Y*9C*D20 UC60D 39.5 3.82 3.03 22.4 2.58 2.54 8.20
GHGD48S41S4
T*(8,L)X*C16 FC/PC60C 45.5 3.70 3.60 27.0 2.86 2.77 8.20
T*(8,L)X*C20 FC/PC60C 45.5 3.72 3.58 26.8 2.88 2.73 8.20
T*9X*C16 FC/PC60C 45.5 3.70 3.60 27.0 2.86 2.77 8.20
T*9X*C20 FC/PC60C 45.5 3.74 3.56 26.8 2.88 2.73 8.20
T*9X*D20 FC/MC/PC60D 44.5 3.80 3.43 26.2 2.96 2.59 8.20
T*(8,L)X*C16 FC/MC62D 45.5 3.66 3.64 26.8 2.86 2.75 8.20
T*(8,L)X*C20 FC/MC62D 45.0 3.70 3.56 26.8 2.88 2.73 8.20
T*9X*C16 FC/MC62D 45.5 3.66 3.64 26.8 2.84 2.76 8.20
T*9X*C20 FC/MC62D 45.0 3.68 3.58 26.8 2.86 2.75 8.20
T*9X*D20 FC/MC62D 45.5 3.64 3.66 27.0 2.84 2.79 8.20
T*(8,L)X*C16 UC60C 45.5 3.68 3.62 26.8 2.84 2.76 8.20
T*(8,L)X*C20 UC60C 44.5 3.82 3.41 26.2 2.96 2.59 8.20
T*9X*C16 UC60C 45.5 3.66 3.64 26.8 2.84 2.76 8.20
T*9X*C20 UC60C 45.0 3.70 3.56 26.8 2.86 2.75 8.20
T*9X*D20 UC60D 44.5 3.76 3.47 26.0 2.94 2.59 8.20
(T*(8,L)C/T*8V)*C16 FC/PC60C 46.0 3.64 3.70 27.2 2.80 2.85 8.20
(T*(8,L)C/T*8V)*C20 FC/PC60C 46.0 3.64 3.70 27.2 2.82 2.83 8.20
(T*9C/T*9V)*C16 FC/PC60C 46.0 3.62 3.72 27.4 2.80 2.87 8.20
(T*9C/T*9V)*C20 FC/PC60C 46.0 3.62 3.72 27.4 2.80 2.87 8.20
(T*9C/T*9V)*D20 FC/MC/PC60D 46.0 3.64 3.70 27.2 2.80 2.85 8.20
(T*(8,L)C/T*8V)*C16 FC/MC62D 45.5 3.64 3.66 27.0 2.84 2.79 8.20
(T*(8,L)C/T*8V)*C20 FC/MC62D 45.5 3.66 3.64 26.8 2.84 2.76 8.20
(T*9C/T*9V)*C16 FC/MC62D 45.5 3.60 3.70 27.0 2.80 2.83 8.20
(T*9C/T*9V)*C20 FC/MC62D 45.5 3.56 3.74 27.2 2.78 2.87 8.20
(T*9C/T*9V)*D20 FC/MC62D 45.5 3.60 3.70 27.2 2.80 2.85 8.20
(T*(8,L)C/T*8V)*C16 UC60C 45.5 3.62 3.68 27.0 2.80 2.83 8.20
(T*(8,L)C/T*8V)*C20 UC60C 45.5 3.68 3.62 26.8 2.84 2.76 8.20
(T*9C/T*9V)*C16 UC60C 45.5 3.58 3.72 27.2 2.78 2.87 8.20
(T*9C/T*9V)*C20 UC60C 45.5 3.58 3.72 27.2 2.78 2.87 8.20
(T*9C/T*9V)*D20 UC60D 45.5 3.60 3.70 27.0 2.78 2.85 8.20
GHGD60S41S4
T*(8,L)X*C20 FC/MC62D 57.0 3.40 4.91 35.8 2.64 3.97 8.20
T*9X*C20 FC/MC62D 57.0 3.34 5.00 35.8 2.60 4.03 8.20
T*9X*D20 FC/MC62D 57.0 3.36 4.97 36.0 2.60 4.06 8.20
T*(8,L)X*C20 FC64D 57.0 3.46 4.83 36.0 2.68 3.94 8.20
T*9X*C20 FC64D 57.0 3.44 4.85 36.0 2.66 3.97 8.20
T*9X*D20 FC64D 57.0 3.46 4.83 35.8 2.64 3.97 8.20
(T*(8,L)C/T*8V)*C20 FC/MC62D 57.0 3.32 5.03 36.0 2.60 4.06 8.20
(T*9C/T*9V)*C20 FC/MC62D 57.0 3.30 5.06 36.4 2.56 4.17 8.20
(T*9C/T*9V)*D20 FC/MC62D 57.0 3.30 5.06 36.2 2.58 4.11 8.20
(T*(8,L)C/T*8V)*C20 FC64D 57.0 3.42 4.88 35.8 2.64 3.97 8.20
(T*9C/T*9V)*C20 FC64D 57.0 3.38 4.94 36.4 2.60 4.10 8.20
(T*9C/T*9V)*D20 FC64D 57.0 3.40 4.91 36.2 2.60 4.08 8.20
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no sup-
plemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
MODEL
FURNACE
MODEL
COIL
1
MODEL
ARI HEATING
2
47F17F HSPF
MBH COP KW MBH COP KW STD