EasyManua.ls Logo

York GHGD24 - Cooling Capacity with Air Handler Coils (Continued)

York GHGD24
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
571921-UTG-A-0410
Johnson Controls Unitary Products 5
— = Not applicable.
13 SEER HP WITH AHP / SHP / AHX / F*FP
GHGD18S41S3
AHP18 17 600 18.0 14.0 13.00 11.00
AHX18 17 600 18.0 14.0 14.50 12.00
F4FP024 17 600 18.0 14.0 13.00 11.00
F6FP018 17 600 18.0 14.0 14.50 12.00
F6FP024 17 610 18.0 14.0 14.50 12.00
GHGD24S41S4
AHP30 17 800 23.8 17.1 13.00 11.00
F4FP040 21 800 23.8 17.1 13.00 11.00
AHX30 17 820 24.0 17.5 14.00 12.00
AHX36 21 820 24.0 17.5 14.00 12.00
F6FP030 17 850 24.0 17.6 14.00 12.00
F6FP036 21 855 24.0 17.6 14.00 12.00
GHGD30S41S4
AHP30 17 1000 30.0 22.2 13.00 11.00
AHP36 21 1000 30.0 22.2 13.00 11.00
AHX30 17 1025 30.0 22.6 14.50 12.00
AHX36 21 1005 30.0 22.4 14.50 12.00
F4FP040 21 1000 29.8 21.8 13.00 11.00
F6FP030 17 1035 30.0 22.0 14.00 11.50
F6FP036 21 980 30.0 22.0 14.50 12.00
GHGD36S41S4
AHP36 21 1200 36.0 26.4 13.00 11.00
AHX36 21 1225 36.0 26.8 14.50 12.00
F6FP042 24 1290 36.0 27.6 14.50 12.00
F5FP048 24 1235 36.0 27.2 14.50 12.00
F4FP045 24 1200 36.0 26.8 13.00 11.00
AHX42 21 1190 36.0 26.8 14.50 12.00
AHP42 21 1255 36.0 27.2 13.00 11.00
GHGD42S41S4
AHX42 21 1395 40.5 32.4 14.00 12.00
F6FP042 24 1455 40.5 32.8 13.50 11.50
AHP60 24 1400 42.0 32.4 14.00 12.00
AHP48 24 1370 41.0 31.0 13.00 11.00
AHX48 24 1445 42.0 33.0 14.50 12.00
F4FP045 24 1400 41.0 31.8 13.00 11.00
F5FP048 24 1455 41.5 32.6 14.00 12.00
F6FP048 24 1380 42.0 32.4 14.50 12.00
F5FP060 24 1485 42.0 33.2 14.00 12.00
GHGD48S41S4
AHP48 24 1685 45.0 34.6 13.00 11.00
AHP60 24 1600 44.5 34.0 14.50 12.00
AHX48 24 1660 45.5 35.0 14.50 12.00
AHX60 24 1570 45.5 34.4 14.50 12.00
F5FP060 24 1665 44.5 34.2 14.50 12.00
F6FP048 24 1625 45.0 34.4 14.50 12.00
F6FP060 24 1570 45.5 34.4 14.50 12.00
GHGD60S41S4
AHX60 24 1830 55.0 40.5 14.00 11.50
F6FP060 24 1875 56.0 41.5 14.00 12.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.

Related product manuals