13 SEER HP WITH AHP / SHP / AHX / F*FP
GHGD18S41S3
AHP18 17 – 600 18.0 14.0 13.00 11.00
AHX18 17 – 600 18.0 14.0 14.50 12.00
F4FP024 17 – 600 18.0 14.0 13.00 11.00
F6FP018 17 – 600 18.0 14.0 14.50 12.00
F6FP024 17 – 610 18.0 14.0 14.50 12.00
GHGD24S41S4
AHP30 17 – 800 23.8 17.1 13.00 11.00
F4FP040 21 – 800 23.8 17.1 13.00 11.00
AHX30 17 – 820 24.0 17.5 14.00 12.00
AHX36 21 – 820 24.0 17.5 14.00 12.00
F6FP030 17 – 850 24.0 17.6 14.00 12.00
F6FP036 21 – 855 24.0 17.6 14.00 12.00
GHGD30S41S4
AHP30 17 – 1000 30.0 22.2 13.00 11.00
AHP36 21 – 1000 30.0 22.2 13.00 11.00
AHX30 17 – 1025 30.0 22.6 14.50 12.00
AHX36 21 – 1005 30.0 22.4 14.50 12.00
F4FP040 21 – 1000 29.8 21.8 13.00 11.00
F6FP030 17 – 1035 30.0 22.0 14.00 11.50
F6FP036 21 – 980 30.0 22.0 14.50 12.00
GHGD36S41S4
AHP36 21 – 1200 36.0 26.4 13.00 11.00
AHX36 21 – 1225 36.0 26.8 14.50 12.00
F6FP042 24 – 1290 36.0 27.6 14.50 12.00
F5FP048 24 – 1235 36.0 27.2 14.50 12.00
F4FP045 24 – 1200 36.0 26.8 13.00 11.00
AHX42 21 – 1190 36.0 26.8 14.50 12.00
AHP42 21 – 1255 36.0 27.2 13.00 11.00
GHGD42S41S4
AHX42 21 – 1395 40.5 32.4 14.00 12.00
F6FP042 24 – 1455 40.5 32.8 13.50 11.50
AHP60 24 – 1400 42.0 32.4 14.00 12.00
AHP48 24 – 1370 41.0 31.0 13.00 11.00
AHX48 24 – 1445 42.0 33.0 14.50 12.00
F4FP045 24 – 1400 41.0 31.8 13.00 11.00
F5FP048 24 – 1455 41.5 32.6 14.00 12.00
F6FP048 24 – 1380 42.0 32.4 14.50 12.00
F5FP060 24 – 1485 42.0 33.2 14.00 12.00
GHGD48S41S4
AHP48 24 – 1685 45.0 34.6 13.00 11.00
AHP60 24 – 1600 44.5 34.0 14.50 12.00
AHX48 24 – 1660 45.5 35.0 14.50 12.00
AHX60 24 – 1570 45.5 34.4 14.50 12.00
F5FP060 24 – 1665 44.5 34.2 14.50 12.00
F6FP048 24 – 1625 45.0 34.4 14.50 12.00
F6FP060 24 – 1570 45.5 34.4 14.50 12.00
GHGD60S41S4
AHX60 24 – 1830 55.0 40.5 14.00 11.50
F6FP060 24 – 1875 56.0 41.5 14.00 12.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.