036-21137-003 Rev. A (1102)
10 Unitary Products Group
1. For condensing unit only. Does not include effect of evaporator motor power or heat.
2. Performance based on 15° superheat and 15° sub-cooling at condensing unit.
a. Increase capacity 1% for each 2° increase in sub-cooling.
b. Decrease capacity 1% for each 2° decrease in sub-cooling.
3. Sub-cooling in excess of 20° may result in excessively high condensing temperature with air on condenser above 115°. Maximum recommended
condensing temperature is 140°F.
H2RC048S06
P1DUC20V G1FA048S21 21 1610 46.5 34.9 - 12.10 11.15
P1DUC20V G2FD048(S,H)21 21 1610 46.5 34.9 - 12.25 11.05
P1XDD20V G2FD048(S,H)24 24 1610 47.0 35.4 - 12.40 11.00
P1XUC16V G1FA048S21 21 1480 46.0 34.4 - 12.10 10.90
P1XUC16V G2FD048(S,H)21 21 1480 46.0 34.4 - 12.30 10.80
P1XUC20V G1FA048S21 21 1590 46.5 34.9 - 12.10 11.10
P1XUC20V G2FD048(S,H)21 21 1590 46.5 34.9 - 12.25 11.00
P1XUD20V G1FA060S24 24 1560 48.5 36.5 - 13.00 11.45
P1XUD20V G2FD048(S,H)24 24 1560 47.0 35.4 - 12.50 11.20
P1XUD20V G2FD060(S,H)24 24 1560 48.5 36.5 - 13.00 11.45
H1RC048S(25,46)
P1DUC20V G1FA048S21 21 1610 45.5 33.7 - 12.20 11.20
P1DUC20V G2FD048(S,H)21 21 1610 45.5 33.7 - 12.25 11.40
P1XUC16V G1FA048S21 21 1480 45.0 33.2 - 12.20 10.95
P1XUC16V G2FD048(S,H)21 21 1480 45.0 33.2 - 12.30 11.10
P1XUC20V G1FA048S21 21 1590 45.5 33.7 - 12.10 11.15
P1XUC20V G2FD048(S,H)21 21 1590 45.5 33.7 - 12.25 11.35
P1XUD20V G1FA060S24 24 1620 47.0 34.8 - 12.75 11.65
P1XUD20V G2FD048(S,H)24 24 1620 45.5 33.7 - 12.25 11.30
P1XUD20V G2FD060(S,H)24 24 1620 47.0 34.8 - 12.75 11.65
H3RC060S06
H1RC060S(25,46)
P1XDD20V G2FD060(S,H)24 24 1805 57.0 42.6 - 11.50 10.00
P1XUC20V G1FA060S21 21 1620 57.0 42.1 - 12.10 10.20
P1XUD20V G1FA060S24 24 1620 57.0 42.1 - 12.10 10.40
P1XUD20V G2FD060(S,H)24 24 1620 57.0 42.1 - 12.10 10.40
P1XUD20V G2FD061
H24 24 1800 58.0 43.2 - 12.10 10.55
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. TXV = Use 1TV700 Series Kit.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
COOLING PERFORMANCE
MODEL
SUCT. T/P
@ COMPR.
AIR TEMP ON CONDENSER
MODEL
SUCT. T/P
@ COMPR.
AIR TEMP ON CONDENSER
75°F95°F115°F75°F95°F115°F
TEMP. PSIG MBH KW MBH KW MBH KW TEMP. PSIG MBH KW MBH KW MBH KW
H2RC018S06
35 61.5 17.19 1.44 13.89 1.59 11.63 1.70
H2RC042S06
35 61.5 35.94 3.12 31.92 3.76 27.86 4.54
40 68.5 18.77 1.45 15.80 1.63 13.53 1.77 40 68.5 39.29 3.15 35.11 3.77 30.80 4.55
45 76.0 20.48 1.47 17.70 1.66 15.04 1.83 45 76.0 42.48 3.21 38.17 3.84 33.70 4.63
50 84.0 21.99 1.48 19.60 1.70 16.81 1.89 50 84.0 45.62 3.23 41.40 3.92 36.56 4.39
H2RC024S06
35 61.5 20.81 1.81 16.82 2.00 14.07 2.14
H2RC048S06
35 61.5 40.62 3.39 36.09 4.08 31.50 4.91
40 68.5 22.73 1.83 19.13 2.05 16.37 2.23 40 68.5 44.42 3.41 39.69 4.09 34.83 4.94
45 76.0 24.80 1.85 21.43 2.09 18.20 2.31 45 76.0 48.02 3.47 43.16 4.16 38.10 5.02
50 84.0 26.63 1.86 23.73 2.14 20.36 2.37 50 84.0 51.58 3.50 46.81 4.25 41.33 4.76
H2RC030S06
35 61.5 26.48 2.34 21.42 2.59 17.91 2.77
H1RC048S(25,46)
35 61.5 39.75 3.32 35.31 3.99 30.82 4.81
40 68.5 28.94 2.36 24.34 2.65 20.84 2.92 40 68.5 43.46 3.34 38.84 4.00 34.08 4.83
45 76.0 31.56 2.39 27.07 2.71 23.17 2.96 45 76.0 46.99 3.40 42.23 4.07 37.28 4.91
50 84.0 33.89 2.40 30.20 2.77 25.92 3.07 50 84.0 50.47 3.43 45.80 4.16 40.44 4.66
H2RC036S06
35 61.5 29.38 2.76 23.75 3.06 19.87 3.26
H3RC060S06
H1RC060S(25,46)
35 61.5 50.26 4.42 44.64 5.32 38.97 6.42
40 68.5 32.09 2.78 27.00 3.13 23.12 3.40 40 68.5 54.95 4.46 49.10 5.33 43.08 6.44
45 76.0 35.01 2.81 30.25 3.19 25.70 3.51 45 76.0 59.41 4.54 53.38 5.43 47.13 6.55
50 84.0 37.59 2.83 33.50 3.26 28.74 3.62 50 84.0 63.81 4.58 57.90 5.55 51.13 6.22
H1RC036S(25,46)
35 61.5 29.20 2.70 23.61 2.99 19.75 3.19
40 68.5 31.90 2.72 26.84 3.06 22.98 3.32
45 76.0 34.80 2.75 30.07 3.12 25.54 3.43
50 84.0 37.36 2.77 33.30 3.19 28.57 3.54
COOLING CAPACITY - With Variable Speed Furnaces
UNIT MODEL
VARIABLE SPEED
FURNACE MODEL
COIL MODEL
1
W
COOLING
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
2
EER
TOTAL SENS.