036-21137-003 Rev. A (1102)
4 Unitary Products Group
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and for 15 feet of
interconnecting line tubing.
2. Verify the orifice size and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for
evaporator + adder for line set.
5. If the orifice in the evaporator was changed, verify the evaporator nameplate has been marked with the correct orifice size.
G1NA060S24T 78
–––––––
––––––703 + 12
G1NF024SOF 63
–––––––
–––––––
G1NF036SOF 67
59 + 12 63 + 0 73 + 7
701 + 12 701 + 0 702 + 7
G1NF048SOF 78
––––78 + 2187 + 6
––––702 + 21 703 + 6
G1NF060SOF 87
–––––87 + 18
–––––703 + 18703 + 0
F2RP024N06 61
53 + 4 59 + 4
701 + 4 701 + 4
F2RP030N06 65
59 + 6 63 + 4
701 + 6 701 + 4
F2RP036N06 75
63 + 4 73 + 8
701 + 4 702 + 8
F2RP042N06 78
73 + 13 78 + 0
702 + 13 702 + 0
F2FP048N06 84
73 + 16 78 + 10 87 + 11
702 + 16 702 + 10 703 + 11
F2FP060N06 90
–––––87 + 15
–––––703 + 15703 + 20
F2FV060N06 90
–––––87 + 15
–––––703 + 15703 + 20
FOOTNOTES:
1. These orifices are factory mounted in the flow control device of each indoor coil and must be removed for TXV installation.
2. A TXV kit must be used with these coils to obtain system performance. (701,702,703 indicates 1TV07 ...series).
3. Systems matched with furnaces or air handlers not equipped with blower-off delays, may require blower Time Delay Kit #6918A5011.
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued)
Outdoor Unit H2RC018S06 H2RC024S06 H2RC030S06 H2RC036S06 H2RC042S06 H2RC048S06 H3RC060S06
Unit Orifice (s)
1
53 59 63 73 78 87
Factory R-22 Charge, lbs-oz. 4 - 9 4 - 7 5 - 8 5 - 3 6 - 13 7 - 7 9 - 0
Indoor Coil
Coil Orifice Orifice or TXV Kit
2
- Additional Charge, Oz.
3