DESCRIPTION
These Sunline 2000 units are completely assembled, piped
and wired at the factory to provide one-piece shipment and
rigging. Each unit is pressurized with a holding charge of
refrigerant-22 for storage and/or shipping.
The compact design, clean styling, low silhouette, and quiet
operation make these condensing units suitable for almost any
outdoor location. On rooftops . . . because they weigh much
less than a single package unit of similar capacity and are much
easier to rig and support. At ground level . . . because their
ample sub-cooling capacity allows them to be located 60 feet
below the evaporator coil.
All sheet metal parts are constructed of commercial grade
(G90) galvanized steel. After fabrication, each part is
thoroughly cleaned to remove any grease or dirt from its
surfaces. The external parts are coated with a ‘‘desert sand’’
powder paint to assure a quality finish for many years. This UL
approved coating system has passed the 750 hour, 20% salt
spray test per ASTM Standard B117.
All models include a 1-year limited warranty on the complete
unit. The compressor carries an additional 4-year warranty.
A complete line of Evaporator Blower units is also offered to
meet your precise capacity and air handling requirements.
Refer to Form 550.23-TG4Y for more information on this air
side equipment.
FEATURES
Condenser coil constructed of copper tubes and
aluminum fins for durability and long lasting efficient
operation.
Permanently attached base rails with fork lift slots and
lifting holes. This design allows for 3-way fork lift access
and overhead rigging.
Both high and low pressure controls. Since these
controls are self-contained, there are no capillary lines
to be damaged.
Compressor line-break motor protection and crankcase
heaters. (No crankcase heater on HCE150 scroll
compressors.)
Anti-short cycle timer to protect the compressor.
A lockout circuit to prevent the unit from cycling on
safety control.
A 24-volt temperature control circuit.
Low ambient operation to 45°F. (Accessories for 0°F low
ambient operation are available.)
A filter-drier (shipped in the unit’s compressor
compartment for field installation near the evaporator
coil).
Service valves with a back-seating access port for
pressure testing the system. Copper stub-outs are
factory mounted on the suction and liquid service valves
to simplify the field piping connections.
Separate panel for easy access to the control box
without affecting air flow across the condenser coil.
Gauge lines extend out from cabinet to facilitate ease
of servicing.
Packaging suitable for outdoor storage.
Optional coil guard accessory protect coils with a
decorative grille.
550.23-TG1Y (298)
SPLIT-SYSTEM
AIR-COOLED
CONDENSING UNITS
H4CE090 & H2CE120 & H1CE150
7-1/2, 10, & 12-1/2 NOMINAL TONS
8.9 - 9.5 EER
SUNLINE 2000
208/230/460
VOLT ONLY
208/230/575
VOLT ONLY

Other manuals for York H1CE150

Question and Answer IconNeed help?

Do you have a question about the York H1CE150 and is the answer not in the manual?

York H1CE150 Specifications

General IconGeneral
BrandYork
ModelH1CE150
CategoryAir Conditioner
LanguageEnglish

Summary

Product Overview and Features

Description

General description of the Sunline 2000 condensing units, their design, and benefits.

Key Features

Highlights of the unit's construction, components, and operational advantages.

Technical Data Tables

ARI Ratings

Performance ratings according to ARI Standards 210 and 270.

Application Data

Operational limitations and environmental data for unit application.

Physical Data

Specifications for compressor, fan, and coil dimensions and weight.

Electrical Data

Electrical specifications including voltage, power supply, and wiring data.

Unit Cooling Capacities and Power Requirements

System Cooling Capacities and Power Requirements

Sequence of Operation

Field Wiring Diagrams and Accessories

Typical Field Wiring w/Air Handler

Diagram showing typical wiring connections for units with air handlers.

Typical Field Wiring with Furnace

Diagram illustrating typical wiring for units with a 7-1/2 ton furnace.

Field-Installed Accessories

Overview of accessories available for field installation.

Unit Dimensions and Clearances

Clearances

Required installation clearances for unit placement and airflow.

Center of Gravity

Location of the unit's center of gravity for lifting and handling.

Point Loads

Guide Specification - Part 1

General Requirements

General manufacturing, quality, and approval standards for the units.

Unit Cabinet

Details on cabinet material, finish, construction, and accessibility.

Compressor

Requirements for compressor type, overload protection, and mounting.

Condenser and Fans

Details on fan motors, coil construction, and subcooler.

Refrigeration Components

List of required refrigeration system components such as cut-outs and filter driers.

Controls

Description of control circuit, safety lockouts, and anti-short cycle timer.

Guide Specification - Part 2

Electrical

Electrical requirements including voltage, phase, and grounding.

Accessories and Options

Information on optional accessories like coil guards and head pressure control.