TECHNICAL GUIDE
SPLIT-SYSTEM
AIR CONDITIONERS
13 SEER
MODELS:
H*RD018 THRU 060
(1.5 THRU 5 NOMINAL TONS)
Due to continuous product improvement, specification
s
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ariprimenet.org.
LISTED
U
N
I
T
A
R
Y
H
E
A
T
P
U
M
P
T
E
Q
U
I
P
M
E
N
R
S
E
C
T
I
O
N
S
A
T
I
O
N
E
R
T
I
F
I
C
C
O
F
D
S
T
A
N
D
A
R
I
A
R
2
4
0
M
A
N
U
F
A
C
T
U
R
E
R
C
E
R
T
I
F
I
E
D
C
L
Y
O
M
P
I
N
G
T
O
A
R
I
A
S
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE
SYSTEM IS LISTED
WITH ARI.
®
036-21339-001 Rev. C (0602)
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The 13 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG’s complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-On coils are available for use
with upflow, downflow, or horizontal furnaces and air han-
dlers.
WARRANTY
5-year limited parts warranty.
10-year limited compressor warranty.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed
of copper tube and aluminum fins.
PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and desert sand matted-textured
finish insure less fading when exposed to sunlight.
LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Discharge line heat exchanger knockouts are pro-
vided, if required. Available in sweat connect models only.
The unit contains enough refrigerant for matching indoor
coils and 15 feet of interconnecting piping. The small base
dimension means less space is required on the ground or
roof.
TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, a single panel covering the electrical controls,
and the molex plug in the control box connecting the con-
denser fan make for easy servicing of the unit.
SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
Question and Answer IconNeed help?

Do you have a question about the York H1RD060S06 and is the answer not in the manual?

York H1RD060S06 Specifications

General IconGeneral
RefrigerantR-410A
Phase1
Tonnage5 Ton
Cooling Capacity60000 BTU
Operating Voltage208/230V

Summary

YORK Heating and Air Conditioning

Technical Guide Overview

Overview of the technical specifications and features of the 13 SEER series air conditioners.

Product Description and Features

Physical and Electrical Data

Model Specifications

Detailed electrical and physical specifications for each model.

Cooling Capacity - Air Handler Coils

1 PH 13 SEER AC with N-AH / G2FD

Cooling performance data for specific air handler coil pairings.

1 PH 13 SEER AC / N1VS - Variable Speed

Cooling performance for variable speed air handler coil pairings.

1 PH 13 SEER AC / F2RP /RC/FP/FC/FV

Cooling performance for specific furnace and coil units.

Cooling Capacity - Variable Speed Furnaces

1 PH 13 SEER AC / P1DU / P1XD/P1XU

Cooling performance for variable speed furnace configurations.

Cooling Capacity - Variable Speed Furnaces (Continued)

Cooling Performance Summary

Performance data at different ambient conditions and superheat/subcooling.

Accessories and Installation

Cooling Performance Data - H1RD018S06

Cooling Performance Data - H1RD024S06

Cooling Performance Data - H1RD030S06

Cooling Performance Data - H1RD036S06

Cooling Performance Data - H1RD042S06

Cooling Performance Data - H1RD048S06

Cooling Performance Data - H1RD060S06