TECHNICAL GUIDE
ADD - ON COILS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: MC, PC, FC, HD, UC
600 - 2000 CFM 1.5 - 5 TON COILS
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ahridirectory.org
UPFLOW/DOWNFLOW
FULL CASED
FC
FULL CASED
MULTI-POSITION
MC
UPFLOW
PARTIAL CASED
PC
HORIZONTAL
DUCT
HD
UPFLOW
UNCASED
UC
ISO 9001
Certified Quality
Management System
813517-YTG-E-0114
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
Heating Air Conditioning
R
DESCRIPTION
These evaporator coils are designed to be installed with UPG fur-
naces or modular air handlers and matched with UPG cooling
and heat pump outdoor units. All coil models are available as
“flex-coil” units without a factory installed metering device. Flex-
coil models allow these coils to be used with R-22 or R-410A for
added flexibility to meet refrigerant system choice. An orifice
metering device or a R-410A TXV should be installed in the field
to meet your system requirements.
FC Models, Full Case Coils - Full cased coils are suitable for
use in upflow or downflow applications.
MC Models, Multi-Position Coils - MC coils have the added
flexibility that allow them to be installed in any position - upflow,
downflow, or horizontal right or left. This coil can be easily
installed with a UPG furnace or modular air handler in any config-
uration.
PC Models, Partial Case Coils - These coils are designed for
installation on top of upflow furnaces. The partial case height on
these coils allows for the flexibility of fabricating the upper portion
of the coil casing in the field. The partial cased coils are for use in
upflow only applications.
UC Models, Uncased Coils - These coils are designed for instal-
lation on top of upflow furnaces, and they are to be used for only
upflow applications. The uncased coils allows field modification of
the furnace duct for the coil installation.
HD Models, Horizontal Duct Coils - Dedicated horizontal, slab
coil available for both cooling and heat pump applications. Field
transition may be required.
FEATURES
Rust-proof plastic drain pans - The vertical and horizontal drain
pans on these coils are made of a fiberglass reinforced thermoset
polymer that will not rust or compromise stability at high tempera-
tures.
Insulated Cabinet - Evaporator coil cabinets are thermally insu-
lated with foil faced insulation to prevent sweating. HD coils use
fiberglass Tuf-Skin® insulation.
Internally Clean - All evaporator coils are factory leak-tested,
dehydrated, sealed and shipped with a holding charge. The suc-
tion and liquid lines are sealed with spun copper fittings with easy
access to attach line set.
Durable Finish Inside and Out - Coil casings are made of pre-
painted steel. Pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep. All
internal metal parts are made of G90 galvanized steel.
Optimum Heat Transfer - Using the latest in heat transfer tech-
nology, staggered rows of copper tubes are mechanically
expanded into aluminum fins to provide optimum air to surface
contact for ample moisture removal as well as high performance
ratings.
ACCESSORIES
Refer to Price Manual for specific model numbers.
TXV Kits - Thermal expansion valve kits are available for flex-coil
applications, for converting R-22 to R-410A refrigerant, or as a
service replacement. All TXV kits are non-braze. All connections
are bolt-on including the valve assembly and equalizer tube. No
orifice or any other metering device is to be used in conjunction
with the TXV.
Coil Casing Without Coil - Coil casings are available in four
widths that can be installed with the furnace or modular air han-
dler during initial installation. This option is available to allow the
installer the flexibility to add the coil at a later date without duct
modifications.
UVC Germicidal Light - The UVC technology effectively pre-
vents mold, bacteria, and other microorganisms that develop in
air handling systems. The UVC Light Kit provides safe, continu-
ous cleaning while actually saving money by reducing HVAC sys-
tem maintenance and energy consumption.
Question and Answer IconNeed help?

Do you have a question about the York MC48C3XC1 and is the answer not in the manual?

York MC48C3XC1 Specifications

General IconGeneral
BrandYork
ModelMC48C3XC1
CategoryAir Conditioner
LanguageEnglish

Summary

YORK Heating & Air Conditioning Technical Guide

Add-On Coils for Split-System Cooling & Heat Pumps

Overview of evaporator coils for split-system cooling and heat pumps, compatible with UPG furnaces.

Coil Features

Highlights rust-proof drain pans, insulated cabinets, clean internal coils, durable finish, and optimal heat transfer.

Available Accessories

Details on TXV kits and UVC germicidal light for enhancing coil performance and system maintenance.

Application Data and Limitations

Application Factor: Rated CFM vs. Actual CFM

Guidance on applying capacity factors based on actual vs. rated airflow for optimal performance.

General Application Limitations

Mandatory adherence to national and local safety codes for proper unit installation and operation.

Static Pressure vs. Airflow

Data correlating static pressure to airflow for wet coil conditions, crucial for system design.

Uncased and Horizontal Coil Physical Data

Uncased Upflow Coil Specifications

Detailed physical data for uncased upflow 'A' type coils, including dimensions and connections.

Horizontal Duct Coil Specifications

Physical data for horizontal duct type coils, covering dimensions, tube geometry, and connections.

Cased Coil Physical Data

Cased Upflow/Downflow and Partial Cased Coil Specs

Physical specifications for cased upflow/downflow and partial cased coils, including dimensions and weight.

Cased Upflow 'A' Type Coil Specifications

Physical data for cased upflow 'A' type coils, listing dimensions, connections, and operating weight.

Full Cased 'A' Type Multi-Position Coil Specs

Physical data for full cased 'A' type multi-position coils, with dimensions, tube geometry, and weight.

Product Dimensions

MC and FC Coil Dimensions

Detailed physical dimensions and refrigerant line sizes for MC and FC series coils.

PC and UC Coil Dimensions

Physical dimensions and refrigerant line sizes for PC and UC series coils, including diagrams.

HD Coil Dimensions

Dimensional data for HD series coils, including diagrams and refrigerant connection sizes.

Related product manuals