Page #1 background image
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
5167798-YTG-J-0218
TECHNICAL GUIDE
Description
ASHRAE 90.1 COMPLIANT
YORK
®
Predator
®
units are convertible single packages with a
common footprint cabinet and common roof curb for all 6.5
through 12.5 ton models. All units have two compressors with
independent refrigeration circuits to provide 2 stages of cooling.
The units were designed for light commercial applications and
can be easily installed on a roof curb, slab, or frame.
All Predator
®
units are self-contained and assembled on rigid
full perimeter base rails allowing for 3-way forklift access and
overhead rigging. Every unit is completely charged, wired,
piped, and tested at the factory to provide a quick and easy field
installation.
Predator
®
units in all tonnage sizes are convertible between
side airflow and down airflow, with corresponding economizer if
economizer option is desired.
Predator
®
units are available in the following configurations:
cooling only, cooling with electric heat, and cooling with gas
heat. Electric heaters are available as factory-installed options
or field-installed accessories.
All units provide constant supply air volume. A variable air
volume (VAV) option, which features a variable frequency drive
(VFD), is available on 6.5 through 12.5 ton models.
Tested in accordance with:
R-410A
ZF SERIES
6.5 - 12.5 TON
60 Hertz
ZF 6.5 THROUGH 10 TON
ZF12.5 TON
®

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the York Predator ZF102 and is the answer not in the manual?

York Predator ZF102 Specifications

General IconGeneral
BrandYork
ModelPredator ZF102
CategoryAir Conditioner
LanguageEnglish

Summary

Nomenclature

Features and Benefits

Standard Features

Key features for ease of service, coil technology, balanced heating, and system protection.

Advanced Controls

Smart Equipment™ control board features and capabilities for improved operation.

Factory Installed Options

Economizer Options

Economizers with low leak dampers for ASHRAE 90.1-2010 compliance.

Control Options

Smart Equipment™ with Communication Option

Factory installed control with gateway for BACnet MS/TP or Modbus/N2 protocols.

Fault Detection and Diagnostics (FDD)

Control system for monitoring refrigerant circuit pressures and temperatures.

Building Automation System (BAS) Controls

Factory installed BAS controllers for integration with building automation systems.

Guide Specifications (Continued)

REFRIGERANT COMPONENTS

Details on compressors, coils, filter driers, and refrigerant circuits.

Unit Controls

Information on the self-contained low-voltage control circuit and safety devices.

GAS HEATING SECTION (IF EQUIPPED)

Construction and protection details for the gas heating section.

Guide Specifications (Continued)

ELECTRIC HEATING SECTION (IF EQUIPPED)

Details on nickel chromium heating elements and slide-out assembly.

UNIT OPERATING CHARACTERISTICS

Unit's ability to start/run at high temperatures and operate down to 0°F outdoor.

FACTORY INSTALLED OPTIONAL OUTDOOR AIR

DRY BULB AUTOMATIC ECONOMIZER

Physical Data

ZF078-150 Physical Data

AHRI cooling performance, heating performance, dimensions, and coil data.

Capacity Performance

Capacity Performance (Continued)

Airflow Performance

Side Duct Airflow Performance

Performance data for side duct applications across different tonnages.

Bottom Duct Airflow Performance

Performance data for bottom duct applications across different tonnages.

Sound Performance

Electrical Data

Standard Motor - Without Powered Convenience Outlet

Electrical specifications for units with standard motors, no powered outlet.

Hi Static Motor - Without Powered Convenience Outlet

Electrical specifications for Hi Static motor units, no powered outlet.

Electrical Data (Continued)

Standard Motor - With Powered Convenience Outlet

Electrical specifications for standard motor units with a powered convenience outlet.

Hi Static Motor - With Powered Convenience Outlet

Electrical specifications for Hi Static motor units with a powered convenience outlet.

Typical Wiring Diagrams

Cooling Unit with Gas Heat Wiring Diagrams

Wiring diagrams for cooling units with gas heat across different voltages.

Cooling Unit with/without Electric Heat Wiring Diagrams

Wiring diagrams for cooling units with or without electric heat.

Typical Wiring Diagrams (Continued)

ZF150 Cooling Unit with Gas Heat Wiring Diagrams

Wiring diagrams for ZF150 cooling units with gas heat across different voltages.

BAS Controls Typical Wiring Diagrams

Related product manuals