All standard efficiency units have a minimum EER of 9.0. Gas/electric units have electronic spark ignition.
Enhancements improve serviceability. Motor and blower slide out as a common assembly for easier access.
Foil-faced insulation used exclusively throughout units for improved Indoor Air Quality.
Offers various optional economizers with low leak dampers; enthalpy sensor enables operation.
Single enthalpy input, 2% low leakage damper, spring return, fully modulating actuators.
Similar to downflow but requires separate barometric relief order for power exhaust.
Uses Belimo actuator with 0-10V DC input from external source for building automation.
Single enthalpy input, 2% low leakage damper, spring return, fully modulating actuators.
Installs with a downflow economizer; requires barometric relief kit.
Includes slide-in damper assembly with hood and filters, opens to preset position when fan is energized.
Optional motors for high static restrictions, providing higher output or airflow.
For non-corrosive environments.
For corrosive environments; full stainless steel assembly.
Optional rust-proof pan for trouble-free operation in corrosive environments.
Range from 9kW to 54kW, dual staged, available in all voltage options.
HACR breaker or switch sized to unit/heater for gas/electric units.
Optional 120VAC GFCI outlet, powered or non-powered.
Stop operation by interrupting power to control board if smoke is detected in air compartment.
Single enthalpy input, 2% low leakage damper, spring return, fully modulating actuators.
Requires separate order for barometric relief and power exhaust for horizontal flow.
Single enthalpy input, 2% low leakage damper, spring return, fully modulating actuators.
Kit to convert a single enthalpy economizer to dual enthalpy.
For use with horizontal flow or field installed slab economizers; zero to 100% capacity.
Installs with a downflow economizer; requires barometric relief for horizontal flow.
Includes damper assembly with hood and filters; available in 0-100% or 0-35% ranges.
Includes damper assembly with hood and filters; opens to preset position when fan is energized.
Stops operation by interrupting power to control board if smoke is detected.
Senses CO2 levels and overrides economizer when levels rise above preset limits.
Differential pressure switch energizes fault light on thermostat for high filter pressure drop.
Decorative wire coil guard to prevent condenser coil damage.
Sloped hood installs over condenser coil to prevent damage from hail strikes.
Prevents flue exhaust from entering nearby fresh air intakes in windy conditions.
Provides electric heat in gas heat controls for low ambient temperatures.
Converts gas heat unit for operation at high altitudes (2,000-6,000 ft).
Converts gas-fired heater from natural gas to propane.
Contains parts for gas supply connection with external shut off.
Range from 9 kW to 54 kW, dual staged, available in all voltage options.
Prevents operation during cold conditions or low supply air setpoints.
Metal frame with polyester filter medium.
Permanent filters are available.
Insulated decks available in 8" and 14" heights for roof curb applications.
Single Piece Adapter (10" High) for transitioning from Sunline™™ to Predator® units.
Mount in supply and return openings to prevent entry into duct work.
Units designed for 24-volt electronic/electro-mechanical thermostats.
D = A/C, Single Pkg., R-22.
M = 9.0 EER A/C.
Lists capacities from 6.5 Ton to 12.5 Ton.
C00 = Cooling Only. No heat installed.
Lists MBH output for Aluminized Steel and Stainless Steel.
Lists KW options from 9 KW to 54 KW.
Lists airflow types (Std. Motor, Hi Static Mtr.) and economizer/exhaust options.
Lists voltage options: 208/230-3-60, 380-3-60, 460-3-60, 575-3-60.
Identifies Third or Fourth Generation units.
Four digits assigned based on requested options or order placement.
Codes for Coil Guard, Shipping Bag, Technicoat coils, etc.
Codes for various factory installed options like economizers, phase monitors.
Codes for Disconnect, Convenience Outlet, Smoke Detector.
Units are convertible single packages with common footprint and roof curb for all models.
Factory assembled, single package units designed for outdoor installation with minimum EER of 9.0.
G90 galvanized steel cabinet with powder paint finish, hinged doors for easy access.
Belt drive assembly with adjustable pitch motor pulley, double inlet fan wheel.
Direct drive fans with aluminum blades, dynamically balanced for smooth operation.
Details on compressors and coils used in the unit.
Expansion devices to control refrigerant flow and protect the system.
Eliminates moisture or foreign matter from refrigerant circuit.
Connections on suction/discharge lines for servicing and troubleshooting.
Circuits are equally split in 50% capacity increments for improved performance.
Protected by a resettable circuit breaker on the 24-volt transformer side.
Provides reset capability at thermostat or base unit for compressor safety trips.
Incorporates over-temperature and over-current protection for compressors.
Unit operates with conventional thermostat designs and has a low voltage terminal strip.
Control board monitors safety switches and displays fault codes.
Includes anti-short cycle, low voltage protection, and cooling down to 0°F.
Control board monitors each refrigerant safety switch independently.
Retains last 5 fault codes in non-volatile memory during power loss.
Aluminized steel construction with induced draft combustion and energy-saving spark ignition.
T1-40 aluminized steel for corrosion resistance, allowing minimum mixed air of 40°F.
In-shot type constructed of aluminum-coated steel with single location piping entry.
Includes high-temp limit switches, induced draft sensor, flame roll out switch, and flame proving controls.
Provides two states of capacity from 9 to 54 KW for heating.
Automatic reset control to prevent overheating of heating elements.
Heating section assembly slides out for easy maintenance and service.
Capable of starting and running at 125°F outdoor temperature, exceeding ARI 340/360 load criteria.
Compressor capable of operation down to 0°F outdoor temperature.
Prevents cold air delivery before heat exchanger warms up (gas heat only).
Power wiring enters at a single factory location, separate openings for control wiring.
Lists warranties for compressor, heat exchanger, electric elements, and parts.
Interlocked dampers, spring-return actuator, 2% max leakage, unit-mounted potentiometer.
Optional motors for high static restrictions, providing higher output or airflow.
Optional 120VAC GFCI outlet with cover near compressors.
Electric heaters range from 9 kW to 54 kW, available in all voltage options.
Prevents unit damage in out-of-phase condition.
14" and 8" high, full perimeter knockdown curb with hinged design.
Relieves internal air pressure through the unit during economizer operation.
Converts natural gas to L.P. gas with new orifices and springs.
Electric heat kit for gas compartment for extreme low ambient conditions.
Factory installed or field installed options for economizer operation.
Accessory for downflow or horizontal flow economizers.
Provides a second input for economizer to monitor return air.