Details the standard efficiency EER and gas/electric unit performance.
Highlights features enhancing ease of maintenance and serviceability.
Mentions foil-faced insulation for improved indoor air quality.
Describes various economizer options for enhanced efficiency.
Details the downflow economizer with barometric relief features.
Explains the horizontal economizer option, excluding barometric relief.
Covers BAS integration with barometric relief economizer.
Describes slab economizer for ERV applications.
Details the power exhaust accessory for downflow units.
Explains the motorized outdoor air damper option.
Options for motors with higher static output or airflow.
Exchanger for non-corrosive environments.
Exchanger for corrosive environments.
Rust-proof option for corrosive environments.
Details electric heater options and specifications.
Factory installed option for safety.
Adds 120V GFCI outlet for power or non-power.
Safety feature to stop operation upon smoke detection.
Details the INTELLI-Comfort control features and sensors.
Adds ModLINC for translating communications between protocols.
Factory installed Novar ETC-3 controller with sensors.
Factory installed JC YK-UNT-1126 controller with sensors.
Factory installed CPC 810-3060 controller with sensors.
Factory installed Honeywell W7750C controller with sensors.
Provides rooftop system integration for YCCS.
Details the field installable downflow economizer with barometric relief.
Explains the field installed horizontal economizer.
Describes the field installable slab economizer for ERV.
Manual damper option for outdoor air intake.
Motorized damper option for outdoor air intake.
Safety feature to stop operation upon smoke detection.
Monitors CO2 levels and overrides economizer.
Indicates high pressure drop across filters.
Protects condenser coil from damage.
Protects coil fins from hail strikes.
Prevents flue exhaust interference.
Enables gas heat operation at low ambient temperatures.
Adapts gas heat units for high altitudes.
Converts gas heat from natural to propane.
Components for gas supply connection.
Details electric heater options and specifications.
Prevents operation in adverse conditions.
Filter kit with metal frame.
Permanent filter options.
Options for roof curb installation.
Adapter for transitioning roof curbs.
Security feature for duct openings.
Notes compatibility with various thermostat types.
Various roof curb options for installation.
Security bars for downflow applications.
Lists various electric heat coil options by voltage.
Manual damper options for air intake.
Motorized damper options for air intake.
Various economizer kits and their features.
Power exhaust units for specific applications.
Kit for dual enthalpy economizer control.
CO2 sensors for air quality control.
Safety smoke detectors for air compartments.
Protection against adverse operating conditions.
Protection for condenser coils.
Identifies the unit type and refrigerant.
Specifies the EER rating and refrigerant type.
Indicates the unit's cooling capacity in tons.
Specifies heating type and capacity.
Details gas heat output in MBH for different materials.
Lists electric heat kW options.
Describes airflow types and motor configurations.
Indicates available unit voltages.
Identifies the unit's generation.
Lists various factory-installed configuration options.
Lists other optional features like coil guards.
Codes for various factory-installed options.
Codes for specific accessories like disconnects.
Details blower dimensions and motor specs.
Provides coil dimensions and fin details.
Details fan motor, CFM, and dimensions.
Provides coil dimensions and fin details.
Specifies refrigerant charge per system.
Lists compressor type and quantity.
Details filter size and quantity.
ARI ratings for MBH, EER, IPLV, CFM, and sound.
Input/output MBH, efficiency, temp rise, and line size.
Nominal electric heat capacity in kW.
Min/max voltage limits for power ratings.
Minimum supply air CFM for electric heat by kW and voltage.
Details motor, sheave, and blower specs for each model.
Lists motor, electrical, and fuse specs for power exhaust.
Shows 4-point load distribution in lbs.
Provides X and Y coordinates for unit center of gravity.
Shows 6-point load distribution in lbs.
Lists load weights at 6 specific points for each model.
Provides shipping and operating weights for each model.
Shows overall unit dimensions and key features.
Lists the height of each unit model.
Specifies required clearances for installation.
Details dimensions for roof curb installation.
Shows dimensions for transition roof curbs.
Illustrates bottom duct opening locations and sizes.
Provides dimensions for rear duct openings by cabinet size.
Illustrates the detail of the downflow economizer hood.
Cross-references applications, cabinet height, and models.
Diagram of the factory installed downflow economizer.
Diagram of field installed downflow economizer with power exhaust.
Diagram of field installed horizontal economizer with power exhaust.
Diagram of slab economizer for downflow with power exhaust.
Diagram of slab economizer for end return with power exhaust.
Electrical schematic for cooling unit with gas heat at 230V.
Electrical schematic for units with or without electric heat.
Electrical schematic for gas heat units at 460/575V and 50Hz.
Covers general description, cabinet, fan assemblies, and refrigerant components.
Details unit controls, diagnostics, gas/electric heating, and operating characteristics.
Lists factory options like economizers, dampers, motors, and controls.
Covers accessories like guards, kits, breakers, and economizers.