Do you have a question about the York PREDATOR DM 150 and is the answer not in the manual?
Brand | York |
---|---|
Model | PREDATOR DM 150 |
Category | Air Conditioner |
Language | English |
Highlights minimum EER and gas/electric unit performance.
Details easy access to components and hinged panels for maintenance.
Notes the use of foil-faced insulation for improved indoor air quality.
Explains the 1st stage gas heating providing 60% capacity for stable temperatures.
Describes side/down airflow convertibility for field flexibility and inventory reduction.
Covers freezestats, filter-driers, high/low pressure switches, and compressor protection.
Summarizes Simplicity™ controls, low ambient operation, and anti-short cycle protection.
Details alarm codes, trouble lights, and memory retention for diagnostics.
Mentions computer automated testing and durable powder paint finish.
Discusses common footprint, roof curb compatibility, and drain pan slope.
Covers solid foundation, forklift access, and overhead rigging capabilities.
Highlights utility knockouts, disconnect switch location, and quick field connections.
Notes belt-drive fan motors for flexibility and optional motors for high static.
Outlines limited warranties for the unit, compressors, and heat exchangers.
Describes economizers with low leak dampers and enthalpy/dry bulb sensor inputs.
Details a 2% low leakage economizer with spring return, modulating dampers.
Requires separate barometric relief order for horizontal flow.
Features a Belimo actuator requiring 0-10V DC input from a BMS.
For ERV applications, single enthalpy input, 2% low leakage.
Accessory for downflow economizer units, plugs into bulkhead connector.
Includes slide-in assembly with hood/filters, 0-100% range.
Optional motors for higher static output or airflow.
For non-corrosive environments, provides protection.
For corrosive environments, offers a full stainless steel assembly.
Optional rust-proof pan for trouble-free operation in corrosive environments.
Range from 9kW to 54kW, dual staged, available in all voltages.
HACR breaker sized to unit or switch for cooling-only units.
Optional 120V GFCI outlet adjacent to compressors.
Stops unit operation if smoke is detected in the air compartment.
INTELLI-Comfort™ features plus ModBUS to BACnet translation.
Factory-installed controller with sensors and switches for BMS integration.
Factory-installed controller with sensors and switches for BMS integration.
Factory-installed controller with sensors and switches for BMS integration.
Factory-installed controller with sensors and switches for BMS integration.
Provides rooftop system integration for YCCS.
Single enthalpy input, 2% low leakage, spring return, modulating dampers.
Requires separate barometric relief for horizontal flow.
For ERV applications, single enthalpy input, 2% low leakage.
Kit to convert a single enthalpy economizer to dual enthalpy.
Dampers for horizontal or slab economizers, zero to 100% capacity.
Accessory for downflow economizer units, plugs into bulkhead connector.
Slide-in assembly with hood/filters, variable entry range (0-35% or 0-100%).
Slide-in/plug-in assembly with hood/filters, 0-100% range.
Stops unit operation if smoke detected in air compartment.
Senses CO2 levels, overrides economizer when levels exceed limits.
Pressure switch energizes fault light for high filter drop.
Decorative wire guard to protect coil from damage.
Sloped hood to prevent coil fin damage from hail strikes.
Prevents flue exhaust interference with fresh air intakes.
Electric heat for gas controls to ensure low ambient operation.
Converts gas heat units for operation at high altitudes (2000-6000 ft).
Converts gas-fired heater from natural gas to propane.
Provides fittings for gas supply connection with external shut-off.
Range from 9kW to 54kW, dual staged, available in all voltages.
Prevents operation in cold conditions and maintains supply air.
Metal frame with polyester filter medium.
Available permanent filters.
Insulated decks, available in 8" and 14" heights.
Adapter for transitioning from Sunline™ to Predator® units.
Mount in openings to prevent entry into ductwork.
For 24-volt electronic/electro-mechanical thermostats.
Explains model number construction from various parameters.
Product line for DM 078-150 models, 9.0 EER.
Manufacturer, unit features, application, installation capabilities.
Outdoor installation, EER, refrigerant, certifications, wiring standards.
Steel construction, insulation, hinged doors, base rails, filters.
Belt drive assembly, adjustable pulley, double inlet fan.
Direct drive, vertical discharge, aluminum blades, balanced.
Hermetic compressors, coils with aluminum fins and copper tubes.
Hermetic compressors and coils with aluminum fins/copper tubes.
Expansion devices, filter drier, service gage connections.
Low-voltage circuit, lockout circuit, auto reset, fault display.
Tubular heat exchanger, induced draft, spark ignition.
Nickel chromium elements, 9-54KW, two states.
High ambient operation, low cooling limit, fan time delay.
Unit power wiring entry, control wiring openings.
Compressor, heat exchanger, electric heat, parts warranties.
Economizer options for outdoor air control.
Interlocked dampers, spring-return actuator, 2% leakage.
2-position, spring-return, 2% leakage, potentiometer adjustment.
Alternate blower motors, convenience outlets, electric heat, phase monitors.
Prevents condenser coil damage.
Sensors and switches for building automation systems.
Pressure switch for high filter drop indication.
HACR breaker factory installed on gas/electric units.
Factory installed disconnect for cooling-only units.
Full stainless steel assembly for corrosive environments.
Rust-proof pan for trouble-free operation in corrosive environments.
Factory mounted and wired in air compartments.
Lists available accessories like roof curbs, economizers, and kits.