York THRU H*RA018 THRU 060 - Cooling Capacity with Furnaces and Coils

York THRU H*RA018 THRU 060
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
036-21121-002 Rev. A (0602)
4 Unitary Products Group
COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils
UNIT MODEL
FURNACE**
COIL
MODEL
COOLING
CFM RANGE
(MIN.-MAX.)
W
RATED
CFM
NET MBH
SEER + TXV
W/O TDR
SEER + TXV
1
+ TDR*
EER
TOTAL SENS.
H1RA018S06
575
725
14,17 G1FA024S14,17 650 18.0 13.3 10.00 - 9.20
14 G1FA030S14 650 19.0 14.1 10.50 - 9.80
- G1HD024 655 18.5 13.7 10.50 - 10.00
17 G1NA024S17G 650 18.0 12.5 10.00 - 9.40
14,17 G1UA024S14,17 650 18.0 13.3 10.00 - 9.20
14 G1UA030S14 650 19.0 14.1 10.50 - 9.80
14,17 G2FD024S14,17 650 19.0 14.1 10.50 - 9.80
17 G2FD030S17 650 19.4 14.4 10.50 - 9.90
14 G2FD035S14 650 19.4 14.4 10.50 - 9.90
H1RA024S06
700
900
14,17 G1FA024S14,17 850 23.8 17.6 10.00 - 9.15
14 G1FA030S14 800 24.4 18.1 10.50 - 9.55
14 G1FA036S14 800 24.0 18.1 10.00 - 9.00
17,21 G1FA036S17,21 850 25.0 18.5 10.00 - 8.95
- G1HD024 820 23.2 17.2 10.00 - 8.80
- G1HD036 800 24.4 18.1 10.60 - 9.80
17 G1NA030S17H 800 23.6 17.5 10.00 - 9.00
21 G1NA030S21B 800 23.6 17.5 10.00 - 9.00
14,17 G1UA024S14,17 850 23.8 17.6 10.00 - 9.15
14 G1UA030S14 800 24.4 18.1 10.50 - 9.55
14 G1UA036S14 800 24.0 18.5 10.00 - 9.00
17,21 G1UA036S17,21 850 25.0 18.5 10.00 - 8.95
14,17 G2FD024S14,17 800 24.4 18.5 10.50 - 9.55
17 G2FD030S17 850 25.0 18.5 10.60 - 9.65
14 G2FD035S14 850 25.0 18.9 10.60 - 9.65
17 G2FD036S17 850 25.6 18.9 10.70 - 9.70
H2RA030S06
875
1125
14 G1FA030S14 1000 28.0 20.7 10.00 - 9.30
14 G1FA036S14 1000 29.2 20.3 10.25 - 9.40
17,21 G1FA036S17,21 1000 29.0 21.5 10.45 - 9.45
- G1HD036 1000 29.6 21.9 10.00 - 9.55
17 G1NA030S17K 1000 29.0 20.4 10.00 - 9.30
21 G1NA030S21M 1050 29.0 20.4 10.00 - 9.20
14 G1UA036S14 1000 29.2 20.3 10.25 - 9.40
17,21 G1UA036S17,21 1000 29.0 21.5 10.45 - 9.45
17 G2FD030S17 1000 29.0 21.5 10.30 - 9.45
14 G2FD035S14 1000 29.0 21.5 10.30 - 9.45
21 G2FD036S21 1000 30.0 22.2 10.50 - 9.65
H2RA036S06
1050
1350
14 G1FA036S14 1200 33.6 24.9 10.00 - 9.10
17,21 G1FA036S17,21 1200 33.6 24.9 10.00 - 9.10
17 G1FA048S17 1200 35.0 25.9 10.30 - 9.40
21,24 G1FA048S21,24 1200 36.0 26.6 10.40 - 9.40
- G1HD036 1200 34.4 25.5 10.00 - 8.90
- G1HD048 1165 34.8 25.8 10.00 - 8.95
17 G1NA036S17J 1200 34.4 25.5 10.00 - 9.20
21 G1NA036S21C 1200 34.4 25.5 10.00 - 9.30
14 G1UA036S14 1200 33.6 24.9 10.00 - 9.10
17,21 G1UA036S17,21 1200 33.6 24.9 10.00 - 9.10
17 G1UA048S17 1200 35.0 25.9 10.30 - 9.40
21,24 G1UA048S21,24 1200 36.0 26.6 10.40 - 9.40
14 G2FD035S14 1200 33.4 24.7 10.00 - 9.10
17 G2FD036S17 1200 33.8 25.0 10.00 - 9.20
21 G2FD036S21 1200 33.8 25.0 10.00 - 9.20
21 G2FD042S21 1200 34.4 25.5 10.15 - 9.30
17 G2FD046S17 1200 34.4 25.5 10.15 - 9.30
For Notes See Page 5.