TECHNICAL GUIDE
96% TWO STAGE
GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
MODELS: TM9T
NATURAL GAS
60 - 120 MBH INPUT
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional efficiency rating information can
be found at www.gamanet.org.
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
444559-YTG-A-0409
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
WARRANTY
Lifetime limited warranty on both heat exchangers to the origi-
nal purchaser; a 20-year limited warranty from original installa-
tion date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial applica-
tions.
5-year limited parts warranty.
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and venr piping.
FEATURES
Two stage heating operation includes two stage gas valve,
two stage inducer operation and 4 speed, direct drive PSC
motor blower operation. Adjustable delay timer allows two
stage operation with a single stage thermostat.
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Blower-off delay for cooling SEER improvement.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement
application.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger with
stainless steel tube/aluminum fin secondary heat exchanger
for outstanding efficiency.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow at
ductblaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Insulated blower compartment for thermal and acoustic
performance.
1/4 turn knobs provided for easy independent door removal.
Internal condensate trap design (patent pending) provides
condensate management options, easy visual operation
check, and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent or
condensate blockage.
Venting applications maybe installed as either 2 pipe sealed
combustion or single pipe vent using indoor combustion air.
Question and Answer IconNeed help?

Do you have a question about the York TM9T and is the answer not in the manual?

Summary

Product Description and Features

Product Description

Overview of compact induced combustion furnaces, their design for residential/commercial use, and Category IV listing.

Key Features

Highlights of the furnaces, including two-stage operation, easy installation, diagnostics, and efficiency.

Warranty Information

Cabinet and Dimensions

Cabinet & Duct Dimensions

Table detailing cabinet sizes, dimensions (A, B, C), and approximate operating weights for different models.

Ratings and Specifications

Ratings & Physical; Electrical Data

Key performance data including input/output MBH, AFUE, temperature rise, blower specs, and wire size.

Filter Performance and Clearances

Filter Performance

Information on airflow capacity without filters and recommended filter sizes for various CFM ratings.

Unit Clearances to Combustibles

Required clearances for upflow, downflow, and horizontal installations to combustible materials.

Accessories

Accessory Options

Details on available kits for propane conversion, venting, condensate neutralization, filter racks, and more.

Blower Performance Data

Blower Performance CFM - Any Position (without filter)

Detailed tables showing airflow (SCFM) at various static pressures for bottom and left-side return configurations.

Overview

This document describes a series of 96% Two-Stage Gas-Fired Residential Multi-Position Gas Furnaces, specifically the TM9T models, designed for natural gas operation with input capacities ranging from 60 to 120 MBH. These compact units are engineered for residential installation in various locations such as basements, closets, alcoves, attics, recreation rooms, or garages, and are also suitable for commercial applications.

Function Description

The furnaces utilize induced combustion, a reliable hot surface ignition system, and high-efficiency heat exchangers. The primary heat exchanger is made of hi-tech tubular aluminized steel, while the secondary heat exchanger features stainless steel tubes and aluminum fins, contributing to outstanding efficiency. The two-stage heating operation is managed by a two-stage gas valve, a two-stage inducer, and a 4-speed direct drive PSC motor blower. An adjustable delay timer allows for two-stage operation even with a single-stage thermostat, optimizing comfort and energy use.

The units are factory-shipped for installation in upflow or horizontal applications and can be easily converted for downflow applications with minimal necessary conversion. They are Category IV listed, allowing for venting through sidewall or roof applications using approved plastic combustion air and vent piping. The 100% shut-off main gas valve provides an extra layer of safety. A 24V, 40 VA control transformer and blower relay are supplied, facilitating add-on cooling systems.

Usage Features

These furnaces are designed for ease of installation and flexibility in application. Their compact 33-inch tall cabinet makes them ideal for various spaces. The units are factory assembled, wired, and tested to ensure safe, dependable, and economical operation upon installation.

For cooling, a blower-off delay feature is incorporated to improve the Seasonal Energy Efficiency Ratio (SEER). Easy access to controls simplifies power and control wiring connections. The built-in, high-level self-diagnostics system includes a fault code display, aiding in troubleshooting and maintenance. The low unit amp requirement makes these furnaces suitable for a wide range of replacement applications.

All models can be converted to use propane (LP) gas with an accessory conversion kit. The electronic Hot Surface Ignition system contributes to fuel cost savings and enhances dependability and reliability. The solid removable bottom panel facilitates easy conversion between different installation orientations.

Airflow leakage is less than 1% of nominal airflow at ductblaster conditions, ensuring efficient air delivery. The design eliminates knockouts, simplifying installation. Movable duct connector flanges offer flexibility in application. The inducer operates quietly and rotates for easy conversion of venting options. The fully supported blower assembly allows for easy access and removal of the blower for maintenance.

External air filters are used, providing maximum flexibility to meet customers' indoor air quality (IAQ) needs. The blower compartment is insulated for both thermal and acoustic performance, contributing to quieter operation. Quarter-turn knobs are provided for easy, independent door removal.

An internal condensate trap design (patent pending) offers various condensate management options, allows for easy visual operation checks, and is self-priming to prevent nuisance problems. Protection mechanisms are included against air intake, exhaust vent, or condensate blockage. Venting applications can be installed as either a 2-pipe sealed combustion system or a single-pipe vent using indoor combustion air.

Maintenance Features

The self-diagnostics system with fault code display simplifies troubleshooting, allowing for quick identification of potential issues. Easy access to controls and the fully supported, easily removable blower assembly streamline maintenance tasks. The internal condensate trap design allows for easy visual checks of its operation.

The lifetime limited warranty on both heat exchangers for the original purchaser (20-year limited warranty for subsequent purchasers from the original installation date) and a 5-year limited parts warranty provide long-term assurance. For commercial applications, a 10-year warranty on the heat exchanger is provided.

York TM9T Specifications

General IconGeneral
Fuel TypeNatural Gas
EfficiencyHigh Efficiency
StagesTwo-Stage
Blower MotorECM
Heat Exchanger MaterialStainless Steel
Heating Capacity40, 000 to 120, 000 BTU/h
AFUE Rating96%
Vent Size2 to 3 inches
WarrantyLifetime Limited on Heat Exchanger, 10-Year Limited on Parts

Related product manuals