TECHNICAL GUIDE
95.5% SINGLE STAGE
GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
MODELS: TG9S
NATURAL GAS
40 - 130 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
Standard 5-year limited Parts warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for
replacement or closing for new home construction.
400991-YTG-E-0210
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and vent piping.
FEATURES
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Blower-off delay for cooling SEER improvement.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable operation.
Low unit amp requirement for easy replacement application.
Single wire twinning or staging feature available.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
4 speed, direct drive PSC motor.
24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Secondary heat exchanger made of corrosion resistant
stainless steel materials.
Timed on, adjustable off blower capability for maximum com-
fort.
Blower door safety switch.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow at duct-
blaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Protection included from air intake, exhaust vent, or conden-
sate blockage.
Venting applications - may be installed as either 2-pipe
(sealed combustion) or single-pipe vent (using indoor com-
bustion air).
No special vent termination required.
1/4 turn knobs provided for easy door removal.
Internal condensate trap design (patent pending) provides
condensate management options, easy visual operation,
and is self-priming to prevent nuisance problems.
Question and Answer IconNeed help?

Do you have a question about the York TG9S and is the answer not in the manual?

York TG9S Specifications

General IconGeneral
BrandYork
ModelTG9S
CategoryFurnace
LanguageEnglish

Summary

Product Description

Key Features

Installation Flexibility

Units can be installed in upflow, horizontal left/right, or downflow applications.

Diagnostic Capabilities

Integrated control module provides self-diagnostics with fault code displays.

Ignition and Heat Exchanger

Features reliable hot surface ignition and advanced tubular heat exchangers.

Blower and Safety Features

Includes timed blower operation, safety switches, and easy access for maintenance.

Venting and Airflow Management

Supports various venting options and ensures low airflow leakage.

Condensate Handling

Features an internal, patent-pending condensate trap design for efficient management.

Warranty Details

Limited Warranties

Offers lifetime, 20-year, 10-year, and 5-year limited warranties for heat exchangers and parts.

Filter Performance

Accessories

Propane Conversion Kit

Accessory kit to convert natural gas units for propane (LP) operation.

Vent Termination Kits

Kits for concentric or sidewall venting installations for combustion air and exhaust.

Condensate Neutralizer

Neutralizer cartridge for drain lines to manage condensate acidity.

Filter Racks

Side and bottom return filter racks available for various cabinet sizes.

Floor Base Kits

Required kits for downflow installations on combustible flooring.

EAC Transition Kits

Kits for integrating EAC accessories with furnace return airflow.

High Altitude Pressure Switches

Kits for adjusting pressure switches for installations above 5,000 feet.

Thermostat Compatibility

Information on compatible thermostat controls for optimum performance.