Johnson Controls Ducted Systems 5894307-UIM-B-0920
SINGLE-STAGE ECM
RESIDENTIAL GAS FURNACES
MODELS: TL9E Series
95% Upflow/Horizontal
- Ultra-Low NOx
Natural Gas Only
INSTALLATION MANUAL
LIST OF SECTIONS
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
GAS PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ELECTRICAL POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
CONDENSATE PIPING AND FURNACE VENTING
CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
COMBUSTION AIR AND VENT SYSTEM . . . . . . . . . . . . . . . . 15
START-UP AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . 23
SAFETY CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
NORMAL OPERATION AND DIAGNOSTICS . . . . . . . . . . . . . 29
REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . 31
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
START-UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
LIST OF FIGURES
Duct Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Furnace and Coil Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Horizontal Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Typical Attic Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Typical Suspended Furnace/Crawl Space Installation . . . . . . . . . . . . 6
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Side Return Cutout Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Left Side Supply Gas Pipe Arrangement . . . . . . . . . . . . . . . . . . . . . . 7
Gas Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Electrical Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Thermostat Chart - Single-Stage AC with Single-Stage Furnaces .10
Thermostat Chart - Single-Stage HP with Single-Stage Furnaces .10
Thermostat Chart - 1H/2C - Single-Stage Furnace (STD-ECM)
- Two-Stage Air Conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Typical - Condensate Drain, Vertical Installation . . . . . . . . . . . . . . . 12
Upflow Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Horizontal Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Elbow Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Home Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Termination Configuration - 1 Pipe . . . . . . . . . . . . . . . . . . . . . . . . . .19
Termination Configuration - 2 Pipe . . . . . . . . . . . . . . . . . . . . . . . . . .19
Termination Configuration - 2 Pipe Basement . . . . . . . . . . . . . . . . .19
Double Horizontal Combustion Air Intake and Vent Termination . . .20
Double Vertical Combustion Air Intake and Vent Termination . . . . .20
Downward Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Direct Vent Air Intake Connection and Vent Connection . . . . . . . . .20
Combustion Airflow Path Through the Furnace Casing . . . . . . . . . .21
Ambient Combustion Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Attic and Crawl Space Combustion Air Termination . . . . . . . . . . . . .23
Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Reading Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Furnace Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
LIST OF TABLES
Unit Clearances to Combustibles . . . . . . . . . . . . . . . . . . . . . . . . 4
Cabinet and Duct Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Recommended Filter Sizes (High Velocity 600 FPM) . . . . . . . . . 7
Ratings and Physical/Electrical Data . . . . . . . . . . . . . . . . . . . . . . 8
Maximum Equivalent Pipe Length . . . . . . . . . . . . . . . . . . . . . . . 16
Elbow Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Equivalent Length of Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Combustion Air Intake and Vent Connection Size at Furnace
(All Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Estimated Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Unconfined Space Minimum Area . . . . . . . . . . . . . . . . . . . . . . . 21
Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Gas Rate (CU FT/HR) at Full Input . . . . . . . . . . . . . . . . . . . . . . 25
Inlet Gas Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Nominal Manifold Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Blower Performance CFM - Any Position (Without Filter) . . . . . 28
These high efficiency, compact units employ induced combustion, reli-
able hot surface ignition, and high heat transfer tubular heat exchang-
ers. The units are factory shipped for installation in upflow or horizontal
applications.
These furnaces are designed for residential installation in a basement,
closet, alcove, attic, recreation room, or garage and are also ideal for
commercial applications. All units are factory assembled, wired, and
tested to ensure safe, dependable, and economical installation and
operation.
These units are Category IV listed and can not be common vented with
another gas appliance as allowed by the National Fuel Gas Code.
SECTION I: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided,
will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided,
could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
Question and Answer IconNeed help?

Do you have a question about the York TL9E100 and is the answer not in the manual?

York TL9E100 Specifications

General IconGeneral
BrandYork
ModelTL9E100
CategoryFurnace
LanguageEnglish

Summary

Safety Information

Safety Requirements and Precautions

Outlines critical safety rules, requirements, and precautions for furnace installation and operation.

Codes and Standards

Details national and local codes and standards applicable to furnace installation.

Furnace Location and Clearances

Guidelines for selecting a safe location and required clearances for installation.

Ductwork and Airflow

Ductwork General Information

Discusses design, installation, and closure requirements for duct systems.

Return Air Connections

Explains upflow, side, bottom, and attic return air connections.

Suspended Furnace Installation

Details methods for suspending furnaces in crawl spaces.

Filter Installation

Filter Installation Guidelines

Instructions and cautions for installing filters externally to the furnace.

Recommended Filter Sizes

Provides recommended filter sizes based on airflow and furnace capacity.

Gas Piping and Pressure

Gas Safety and Installation

Covers safety precautions, installation procedures, and gas valve operation.

Calculating Furnace Input Rate

Explains how to measure and verify the furnace's input rate using gas meter readings.

Manifold Gas Pressure Adjustment

Details how to measure and adjust manifold gas pressure for optimal performance.

Electrical Connections and Control

Power Supply and Wiring

Covers high voltage power connections, grounding, and wire requirements.

Low Voltage Control Wiring

Details thermostat wiring and connections to the furnace control board.

Thermostat Wiring Charts

Provides diagrams for connecting thermostats with AC and heat pump systems.

Condensate Management

Condensate Drain Installation

Details how to install condensate traps and drain lines for upflow and horizontal configurations.

Condensate Drain Termination

Explains proper termination methods for condensate drains, including sump pumps.

Combustion Air and Vent System

Vent Clearances

Specifies required clearances for direct vent terminal installations.

Vent System Configurations

Describes horizontal and vertical vent system options and termination requirements.

Combustion Air Supply

Covers requirements for outdoor, ambient, and ventilated combustion air sources.

Downward Venting Procedures

Outlines rules for installing vent and intake pipes in a downward direction.

Start-Up and Adjustments

Initial Start-Up Checks

Lists essential checks like gas piping, ignition, input rate, and temperature rise.

System Start-Up Sequence

Describes the step-by-step process the furnace follows during ignition and operation.

Manifold Pressure and Input Rate

Details procedures for adjusting gas pressure and calculating input rate.

Temperature Rise and Fan Settings

Explains how to adjust temperature rise and fan control settings.

Safety Controls and Diagnostics

Control Circuit and Safety Switches

Covers fuses, door switches, limit switches, and pressure sensors.

Furnace Control Diagnostics

Explains the self-diagnostic system using LED flash codes for fault identification.

Diagnostic Fault Code Storage

Details how to retrieve and clear stored error codes from the control board.

Normal Operation and Troubleshooting

Furnace Operation Sequences

Describes the normal operating sequences for continuous blower, cooling, and heating cycles.

Troubleshooting and Fault Codes

Provides guidance for troubleshooting common issues and interpreting diagnostic codes.

Replacement Parts

Parts List and Contact Information

Lists available replacement parts and provides contact details for ordering.

Wiring Diagram

Electrical Schematics and Legend

Presents the furnace wiring diagram, legend, and service notes.

Start-Up Procedures

Start-Up Checklist

Provides a detailed checklist for performing a furnace start-up.

Performance Data Recording

Sections for recording gas, static pressure, and blower speed measurements.

Related product manuals