5581709-YTG-C-0619
10 Johnson Controls Ducted Systems
— = Not Applicable.
MP Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
YCD30B22S CF/CM42D 24.5 800 - 1200 1000 29.0 22.8 13.00 11.25
YCD36B22S CF/CM/CU36B 17.5 1000 - 1400 1200 35.2 26.0 13.00 11.00
YCD36B22S CF/CM/CU36C 21.0 1000 - 1400 1200 35.2 27.6 13.00 11.00
YCD36B22S CF/CM/CU42C 21.0 1000 - 1400 1200 35.4 28.0 13.00 11.00
YCD36B22S CF/CM/CU48C 21.0 1000 - 1400 1200 35.6 28.0 13.25 11.25
YCD36B22S CF/CM/CU48D 24.5 1000 - 1400 1200 35.6 28.0 13.25 11.25
YCD36B22S CF/CM36D 24.5 1000 - 1400 1200 35.2 27.6 13.00 11.00
YCD36B22S CF/CM42D 24.5 1000 - 1400 1200 35.4 28.0 13.00 11.00
YCD36B22S CF42B 17.5 1000 - 1400 1200 35.4 28.0 13.00 11.00
YCD42B22S CF/CM/CU42C 21.0 1200 - 1600 1400 40.0 28.6 13.00 11.00
YCD42B22S CF/CM/CU48C 21.0 1200 - 1600 1400 40.0 31.6 13.00 11.25
YCD42B22S CF/CM/CU48D 24.5 1200 - 1600 1400 40.0 31.6 13.00 11.25
YCD42B22S CF/CM/CU60C 21.0 1200 - 1600 1400 40.0 31.4 13.00 11.25
YCD42B22S CF/CM42D 24.5 1200 - 1600 1400 40.0 31.8 13.00 11.00
YCD42B22S CF/CM64D 24.5 1200 - 1600 1400 41.0 32.8 13.00 11.25
YCD48B21S CF/CM/CU48C 21.0 1400 - 1800 1600 46.0 33.5 13.00 11.00
YCD48B21S CF/CM/CU48D 24.5 1400 - 1800 1600 46.0 33.5 13.00 11.00
YCD48B21S CF/CM/CU60C 21.0 1400 - 1800 1600 48.0 36.0 13.00 11.25
YCD48B21S CF/CM/CU60D 24.5 1400 - 1800 1600 48.0 36.0 13.00 11.25
YCD48B21S CF/CM64D 24.5 1400 - 1800 1600 48.0 36.0 13.00 11.25
YCD60B21S CF/CM/CU60C 21.0 1520 - 1920 1720 55.0 40.0 13.00 11.00
YCD60B21S CF/CM/CU60D 24.5 1520 - 1920 1725 55.0 40.0 13.00 11.00
YCD60B21S CF/CM64D 24.5 1520 - 1920 1725 56.5 41.0 13.00 11.00
For rated condition information, see the footnotes below the System Capacity - Single Piece and Modular Air Handlers table.
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings) (Continued)
UNIT MODEL
COIL
CFM RANGE
(MIN.-MAX.)
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER
1
EER
TOTAL SENS.
COOLING CAPACITY - With High Efficiency Motor Furnaces
1
UNIT
MODEL
FURNACE
COIL
MODEL
2
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
YCD18B22S TL8E060A12UH11 14.5 CF/CM/CU18A 600 17.7 14.2 14.75 12.50
YCD18B22S TL8E060A12UH11 14.5 CF/CM/CU18B 650 17.7 14.7 15.00 12.50
YCD18B22S TL8E060A12UH11 14.5 CF/CM/CU24A 600 17.8 14.2 15.00 12.50
YCD18B22S TL8E060A12UH11 14.5 CF/CM/CU24B 700 18.0 15.4 15.00 12.50
YCD18B22S TL8E060A12UH11 14.5 CF/CM/CU30A 650 17.8 14.7 15.00 12.50
YCD18B22S TL8E060A12UH11 14.5 CF/CM/CU30B 650 18.0 14.9 15.00 12.50
YCD18B22S TL8E060A12UH11 14.5 CF/CM/CU36B 700 18.0 15.3 15.00 12.50
YCD18B22S TL8E060A12UH11 14.5 CF/CM36A 625 18.0 14.6 15.00 12.50
YCD18B22S TL9E060B12UH11 17.5 CF/CM/CU18B 650 17.7 14.7 15.00 12.50
YCD18B22S TL9E060B12UH11 17.5 CF/CM/CU24B 650 18.0 14.8 15.00 12.50
YCD18B22S TL9E060B12UH11 17.5 CF/CM/CU30B 625 18.0 14.5 14.75 12.50
YCD18B22S TL9E060B12UH11 17.5 CF/CM/CU36B 650 18.0 14.9 15.00 12.50
YCD18B22S TL9E060B12UH11 17.5 CF/CM/CU36C 700 18.0 15.3 15.00 12.50
YCD18B22S TL9E060B12UH11 17.5 CF/CM24C 700 18.0 15.4 15.00 12.50
YCD18B22S TL9E060B12UH11 17.5 CF/CM30C 650 18.0 14.9 15.00 12.50
YCD18B22S TM8E040A12MP11 14.5 CF/CM/CU18A 650 17.7 14.7 15.00 12.50
YCD18B22S TM8E040A12MP11 14.5 CF/CM/CU18B 675 17.8 14.8 15.00 12.50
YCD18B22S TM8E040A12MP11 14.5 CF/CM/CU24A 650 18.0 14.8 15.00 12.50
YCD18B22S TM8E040A12MP11 14.5 CF/CM/CU24B 700 18.0 15.4 15.00 12.50
YCD18B22S TM8E040A12MP11 14.5 CF/CM/CU30A 625 17.9 14.4 14.75 12.50