3. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
* Notates “Hot Heat Pump” performance. These ratings are not AHRI listed.
MP Modular Air Handlers use Coil Only Ratings.
YHE48B22S AE48CX21 21.0 – 1400 46.0 31.8 14.25 12.00 47.5 31.4 9.00 – 3.58 2.64
YHE48B22S AE48DBC21 24.5 – 1400 46.5 32.0 14.5 12.25 47.5 31.4 9.00 – 3.62 2.66
YHE48B22S AE48DX21 24.5 – 1400 46.5 32.0 14.5 12.25 47.5 31.4 9.00 – 3.62 2.66
YHE48B22S AVC48CX21 21.0 – 1375 46.0 31.6 14.25 12.00 47.5 31.4 9.00 – 3.56 2.62
YHE48B22S AVC48DX21 24.5 – 1400 46.5 31.6 14.75 12.25 47.5 31.2 9.00 – 3.60 2.66
YHE48B22S AVC60CX21 21.0 – 1350 46.5 31.6 15.00 12.50 47.5 31.2 9.00 – 3.56 2.62
YHE48B22S ME14DN21 24.5 CF/CM48D 1400 46.5 32.0 14.50 12.25 47.5 31.4 9.00 – 3.60 2.66
YHE48B22S ME14DN21 24.5 CF/CM60D 1400 46.5 32.0 14.25 12.00 48.0 31.4 9.00 – 3.54 2.60
YHE48B22S ME14DN21 24.5 CM48DBCA1 1400 46.5 32.0 14.50 12.25 47.5 31.4 9.00 – 3.60 2.66
YHE48B22S ME16CN21 21.0 CF/CM48C 1400 46.0 31.8 14.50 12.00 47.5 31.4 9.00 – 3.58 2.64
YHE48B22S ME16CN21 21.0 CF/CM60C 1400 47.0 32.2 14.50 12.25 47.5 31.2 9.00 – 3.58 2.62
YHE48B22S ME16CN21 21.0 CF48CBCA1 1400 46.0 31.8 14.50 12.00 47.5 31.4 9.00 – 3.58 2.64
YHE48B22S ME16CN21 21.0 CM48CBCA1 1400 46.0 31.8 14.50 12.00 47.5 31.4 9.00 – 3.58 2.64
YHE48B22S ME20DN21 24.5 CF/CM48D 1400 46.5 31.8 14.50 12.00 47.5 31.4 9.00 – 3.60 2.66
YHE48B22S ME20DN21 24.5 CF/CM60D 1400 47.0 32.2 14.75 12.25 47.5 31.2 9.00 – 3.58 2.64
YHE48B22S ME20DN21 24.5 CM48DBCA1 1400 46.5 31.8 14.50 12.00 47.5 31.4 9.00 – 3.60 2.66
YHE48B22S MVC16CN21 21.0 CF/CM48C 1425 46.0 31.8 14.50 12.00 47.5 31.4 9.00 – 3.60 2.64
YHE48B22S MVC16CN21 21.0 CF48CBCA1 1425 46.0 31.8 14.50 12.00 47.5 31.4 9.00 – 3.60 2.64
YHE48B22S MVC16CN21 21.0 CM48CBCA1 1425 46.0 31.8 14.50 12.00 47.5 31.4 9.00 – 3.60 2.64
YHE48B22S MVC20DN21 24.5 CF/CM48D 1350 46.5 32.0 14.50 12.25 47.5 31.2 9.00 – 3.62 2.68
YHE48B22S MVC20DN21 24.5 CF/CM60D 1475 47.5 33.2 15.00 12.50 47.5 31.4 9.00 – 3.64 2.66
YHE48B22S MVC20DN21 24.5 CM48DBCA1 1350 46.5 32.0 14.50 12.25 47.5 31.2 9.00 – 3.62 2.68
YHE60B22S AE60DBG21 24.5 – 1650 55.5 38.6 14.00 12.00 57.0 37.8 9.00 8.65 3.88 2.82
YHE60B22S AE60DX21 24.5 – 1650 55.5 38.6 14.00 12.00 57.0 37.8 9.00 8.65 3.88 2.82
YHE60B22S AVC60DX21 24.5 – 1550 55.5 39.5 14.25 12.00 57.0 37.8 9.00 – 3.88 2.82
YHE60B22S ME20DN21 24.5 CF/CM64D 1600 55.0 38.0 14.25 12.00 57.0 37.6 9.25 – 3.88 2.82
YHE60B22S MVC20DN21 24.5 CF/CM64D 1600 55.5 38.5 14.25 12.00 57.0 37.6 9.25 – 3.90 2.82
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
1. Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
2. Heating MBH based on AHRI standards of 70°F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
COP (Coefficient of Performance) equals Heating MBH output divided by (total KW input x 3.412).
SYSTEM CAPACITY - Single Piece and Modular Air Handlers
UNIT
MODEL
AIR HANDLER
COIL
MODEL
3
RATED
CFM
COOLING
1
HEATING
2
MODEL WIDTH
NET MBH
SEER EER
NET MBH
HSPF
Region IV
HSPF
Region V
COP
TOTAL SENS. 47°F OD 17°F OD 47°F OD 17°F OD