- 3 -
WARNING: Check local zoning laws for electric
fencing guidelines in your area. Also check with local
utilities before digging to identify any buried cables or
natural gas lines.
In a double-insulated controller, two systems of
insulation are provided instead of grounding. No
means of equipment ground is provided in the supply
cord of a double-insulated controller, nor should a
means for equipment grounding be added to the
controller. Servicing of a double-insulated controller
requires extreme care and knowledge of the system,
and should be done only by qualified service personnel.
Replacement parts for a double-insulated controller
must be identical to the parts they replace.
Tools Required
• Wire cutter/stripper (part no. FWC-1)
• Flathead and phillips screwdrivers
• Adjustable wrench
• Voltage tester (part no. DEFT-1 or RSVT8)
Other Required Components
• Two lengths of 20 KV insulated hook-up wire (one long
enough to connect fence controller to ground system
and one long enough to connect fence controller to
fence line)
• Fence line connector (part no. 07110-96 for steel or
poly wire; PRS2 for poly rope; or PTCC1 for poly tape)
• 6- to 8-foot ground rod(s) (part no. GR8 or 07104-96)
• Ground rod clamps–one per ground rod (part no.
CGR1 or 07105-96)