TECHNICAL MANUAL
A100K10370
Configuration & Installation Manual
Public Address & General Alarm System
SPA-V2
LS zone 1
Cabins
LS zone 2
LS zone 3
LS zone 4
Lifeboat area
PA microphone panel
PA microphone & Alarm panel
Alarm panel
Entertainment
LS zone 5
LS zone 6
Engine
area
Open deck
GENERAL
ABANDON
MANUAL
RESET
EMS
SPARE
SPA-A6CD
1
2
3
4
5
6
ALL
SPA-M6D
TALK
DIM.
Open deck
ACM Integrated System
ACM Telephone System
Telephone
PABX
Accommodations
Weatherproof
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
GENERAL
ALARM
ABANDON
ALARM
MANUAL
ALARM
EMERGENCY
PA
Talk-Back
SPA-V2 Main Unit

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Zenitel Vingtor Stentofon SPA-M6-D and is the answer not in the manual?

Summary

Introduction to SPA-V2 System

About this Document

Provides the scope and target audience for the SPA-V2 system manual.

Publication Log

Lists document revisions, dates, authors, and comments.

Related Documents

Lists other documentation relevant to the SPA-V2 system.

Rules and Regulations

Outlines SOLAS requirements and class society standards met by the system.

Installation and Configuration Procedures

General Description of SPA-V2 System

Overview of installation and configuration procedures for the SPA-V2 system.

Receiving and Inspecting Equipment

Guidelines for checking SPA system delivery for damage before installation.

Planning the Installation

Discusses rack design based on system functions and loudspeaker planning.

Cable Requirements

Specifies requirements for ship cables, including type, shielding, and flame-retardant properties.

Power Supply Requirements

Details recommended specifications for 230V AC and 24V DC power inputs.

Installation and Outline Specifications

Provides outline drawings, panel cutouts, and mounting hole dimensions.

Connecting Equipment

Shows connection drawings for units and the SPA rack, detailing system configurations.

Connecting Power Supply 1

Details the connection for the primary 230V AC main and 24V DC emergency power.

Connecting SPA-M1-V2 & SPA-AC6

Illustrates the wiring between SPA-M1-V2 microphone panels and SPA-AC6 alarm panels.

Connecting SPA-M6-D & SPA-AC6-D

Shows the connection schematic for SPA-M6-D and SPA-AC6-D units.

Connecting SPA-W1-V2

Details the wiring for the SPA-W1-V2 weatherproof PA panel.

Connecting SPA-W1 AR-V2

Illustrates the connection diagram for the SPA-W1AR-V2 weatherproof PA and alarm panel.

Connecting SPA-W6 A4

Shows the connection schematic for the SPA-W6A4 weatherproof PA and alarm panel.

Connecting Loudspeaker in Single System

Explains how to connect loudspeakers in a single system configuration.

Connecting Loudspeaker & Volume Controls in Single Entertainment System

Details connecting loudspeakers and volume controls for a single entertainment setup.

Connecting Loudspeaker & Volume Controls in A+B System in Two Racks

Shows connections for loudspeakers and volume controls in an A+B system across two racks.

Connecting Talk-Back System

Provides instructions for connecting the talk-back system.

Connecting PABX & Entertainment

Illustrates connections for PABX and entertainment sources.

Configuration Example 1: Microphone panels, PABX

Presents a configuration example involving microphone panels and PABX.

Configuration Example 2: Microphone, Alarm Panels, PABX

Demonstrates a configuration example with microphone, alarm panels, and PABX.

Configuration Example 3: Dual PA;GA

Shows a configuration example for a dual PA/GA system setup.

Configuration Example 4: Required PA;GA Connection between Racks 1 & 2

Details the PA/GA connection requirements between two system racks.

Jumper Settings for Configuration of Functions

Explains how jumpers are set for system configuration and modifications.

Jumper settings on SPA Terminal Board

Details jumper settings on the SPA terminal board for various functions.

Jumper settings on SPA-EMS-V2 board (990-362)

Describes jumper settings on the SPA-EMS-V2 board for audio output to external equipment.

Volume Control Override

Explains activation of volume override via different jumper settings.

Jumper Settings on 4-Way Entertainment 6 Zones Board (990-363)

Details jumper settings for the 4-Way Entertainment 6 Zones board.

Jumper Settings on SPA Multi 4-Way Entertainment 6 Zones Board (990-338)

Covers jumper settings for the SPA Multi 4-Way Entertainment 6 Zones board.

Volume Adjustment on SPA Terminal Board

Explains input signal level adjustments for various components on the SPA terminal board.

Volume Adjustment on Amplifier VPA-120;VPA-240;VPA-400

Details volume adjustments on specific amplifier models.

Volume Adjustment on Amplifier EA1400;EA1600

Describes volume, bass, and treble adjustments on EA1400/EA1600 amplifiers.

Loudspeaker Power Consumption

Discusses calculating and managing loudspeaker network power consumption.

Alarm Setup

Covers configurations for alarm tones and priorities using DIP switches.

Alarms and Priorities

Explains the priority order for different alarm types.

Possible Configuration of Alarm Relay Boards

Lists available alarm relay boards and their configurations.

Frequency Change on Alarm

Details the procedure for changing alarm frequency, requiring Zenitel personnel.

Alarm 1

Defines the parameters and settings for Alarm 1.

Alarm 2

Defines the parameters and settings for Alarm 2.

Alarm 3

Defines the parameters and settings for Alarm 3.

Alarm 4

Defines the parameters and settings for Alarm 4.

Alarm 5

Defines the parameters and settings for Alarm 5.

Alarm 6

Defines the parameters and settings for Alarm 6.

Alarm 7

Defines the parameters and settings for Alarm 7.

Alarm 8

Defines the parameters and settings for Alarm 8.

Alarm 9

Defines the parameters and settings for Alarm 9.

Alarm 10

Defines the parameters and settings for Alarm 10.

Alarm 11

Defines the parameters and settings for Alarm 11.

Alarm 12

Defines the parameters and settings for Alarm 12.

Alarm 13

Defines the parameters and settings for Alarm 13.

Alarm 14

Defines the parameters and settings for Alarm 14.

Alarm 15

Defines the parameters and settings for Alarm 15.

FIRE Alarm

Details how to activate the FIRE alarm using DIP switches and the FIRE button.

Commissioning Procedures

General Commissioning Overview

States that the system is pre-tested and outlines post-installation checks.

Mechanical Inspection

Procedures for checking the physical installation and condition of equipment.

Cable Connection Inspection

Verifies cable connections, types, shielding, and grounding.

Power Supply;Consumption Check

Confirms power supply compliance and checks total network power consumption.

Function Configuration Check

Verifies jumper settings, audio adjustments, and priorities after installation.

Startup Procedure

Step-by-step guide for system startup and testing of all functions.

Appendix A: Local Mute

Local Mute Functionality

Explains the use of local mute to prevent PA panel/loudspeaker feedback.

Appendix B: Custom Alarm Configuration Example

Custom Alarm Configuration Example

Provides an example configuration for a standard 4002 alarm using software settings.

Appendix C: Alarm Tone Pattern

Alarm Tone Patterns Overview

Illustrates various alarm tone patterns like Pulse, Latched, General Alarm, and Abandon.

Zenitel Vingtor Stentofon SPA-M6-D Specifications

General IconGeneral
BrandZenitel
ModelVingtor Stentofon SPA-M6-D
CategorySecurity System
LanguageEnglish

Related product manuals