Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
DEC15.0401 © 2015 Zephyr Ventilation LLC.
Siena Pro
ZSP-E42AS
ZSP-E48AS

Questions and Answers

  • B
    Brian CrosbyAug 14, 2025
    How to fix a vibrating mesh filter in Zephyr Hoods?
    • O
      Olivia KingAug 14, 2025
      If the mesh filter in your Zephyr Hoods is vibrating, there are a couple of possible causes: * The mesh filter might be loose. Make sure the metal clips in the handle are not stuck, or consider replacing the mesh filter. * The filter spring clip could be loose or broken. Try uninstalling and reinstalling the filter, pushing up on the filter latch. If needed, replace the mesh filter.
  • J
    Julie BellAug 17, 2025
    What to do if my Zephyr Hoods unit doesn’t work after installation?
    • H
      Heather LopezAug 17, 2025
      If your Zephyr Hoods unit doesn't work after installation, there are several possible causes: * The power source might not be turned on. Ensure that both the circuit breaker and the unit's power are switched on. * The power line and cable locking connector might not be connected properly. Verify that the power connection to the unit is secure. * The wires on the control board could be loose. Check and ensure that all wires on the control board are properly connected. * The wirings between the switch board and control board may be disconnected. Make sure these wirings are properly connected. * The switch board or control board might be defective. If this is the case, consider changing the switch board or control board.
  • E
    Erik HillAug 21, 2025
    Why is my Zephyr Hoods not venting out properly?
    • C
      Cheryl BellAug 21, 2025
      If your Zephyr hood isn't venting properly, several factors could be the cause: * The hood might be hanging too high from the cook top. Adjust the distance between the cook top and the bottom of the hood to be within the 26” to 34” range. * Wind from opened windows or doors could be affecting ventilation. Close all windows and doors to eliminate outside wind flow. * There may be a blockage in the duct opening or ductwork. Remove any blockages from the duct work or duct opening. * The duct opening direction could be against the wind. Adjust the duct opening direction. * The ducting size might be incorrect. Change the ducting to at least a 10” or higher size.
  • T
    tamararoseAug 25, 2025
    What to do if my Zephyr Hoods light works, but the blower isn't turning?
    • A
      Ashley KennedyAug 25, 2025
      If the light on your Zephyr Hoods is working but the blower isn't turning, consider these potential issues: * The blower cable might be disconnected. Check all wirings from the blower to ensure all cables are properly connected. * The blower could be defective, possibly seized. In this case, you may need to replace the blower. * The thermally protected system might have shut down the blower due to overheating. The blower should function properly after the system cools down. * The switch board or control board could be defective. Replacing the defective part may resolve the issue.
  • T
    Tonya RogersAug 27, 2025
    Why is my Zephyr Hoods unit vibrating?
    • S
      Scott ChavezAug 27, 2025
      If your Zephyr Hoods unit is vibrating, it could be due to the following reasons: * The motor might not be securely in place. Tighten the motor to secure it. * The blower wheel could be damaged. Replace the blower if this is the case. * The hood itself might not be secured in place. Check the installation of the hood to ensure it is properly secured.
  • C
    Charles JonesAug 30, 2025
    What to do if my Zephyr Hoods blower is working, but the lights are not?
    • S
      shannonrileyAug 31, 2025
      If the blower in your Zephyr Hoods is working, but the lights are not, here are a couple of things to check: * The halogen bulb might be defective. Replace the halogen bulb. * The halogen bulb wire might be loose. Check the bulb wire connections at the control board and the light bulbs, and reconnect any loose wires.
  • K
    Kimberly JonesSep 3, 2025
    Why does my Zephyr Hoods unit turn on by itself?
    • E
      Eric GarciaSep 3, 2025
      If your Zephyr Hoods unit turns on by itself, it may be because a spotlight or kitchen lamp is shining directly onto the switch controls. These controls are light sensitive, and a direct light source can disrupt their function.
  • K
    Kenneth BrownSep 6, 2025
    Why do all the speed levels on my Zephyr Hoods blower sound the same?
    • N
      Nancy LawsonSep 6, 2025
      If the speed levels of your Zephyr Hoods blower all sound the same, it might be due to using the wrong size of ducting. Try changing the ducting to at least 10” or higher.
  • J
    jonesjohnSep 10, 2025
    How to stop Zephyr Hoods unit from whistling?
    • J
      Jeffrey HernandezSep 10, 2025
      To stop your Zephyr Hoods unit from whistling, you can try the following: * Adjust the filters until the whistling stops. * Check the duct pipe connections to ensure all connections are properly sealed.

Zephyr ZSP-E42AS Specifications

General IconGeneral
LightingLED
FinishStainless Steel
MaterialStainless Steel
ControlsElectronic
Width42 inches
Duct Size6 inches
Venting OptionsDucted