BETAPACK3 USER GUIDE
Zero88 Lighting Ltd, Usk House, Llantarnam Park, Cwmbran, Gwent NP44 3HD, U.K www.zero88.com
Tel: +44 (0) 1633 838088 (24hr Answer Phone) Fax: +44 (0) 1633 867880 Email: sales@zero88.com
73-682-00 IM8025Betapack3ManualIssue1_0.doc Page 4 of 7
Specification Overview
The Betapack3 is a well specified versatile dimmer,
offering six channels each capable of driving up to
10Amp loads.
The Betapack3 features breakers as standard, preheat,
topset and 3 laws per channel, 12 memories, 3 99-step
sequences, local control and DMX patch per channel.
An isolated DMX512-A input and loop-through allow for
remote operation. When the loop-through plug is not
inserted, the DMX line is automatically terminated.
Control Interface
The main display consists of four seven-segment
displays; the data displayed is dependent on the set-up
mode of the Betapack3. Around the outside of these
displays are eight red LEDs which indicate the current
set-up mode of the Betapack3. An additional green LED
is used for DMX indication.
The Betapack3 has a default mode, for operation. In
this mode non of the set-up mode LEDs will be lit, and
the main display will show the DMX address(es).
Mode Button
The Mode button is used to cycle through the different
set-up modes. They are;
- Manual control
- DMX address
- DMX fail
- Memory
- Sequence
- Preheat
- Topset
- Law
Enter Button
The Enter button is used to confirm actions.
Up & Down Buttons
These are used to adjust the values shown in the main
display. Pressing both buttons together will reset the
display to the default values.
Default Mode
If a block patch has been set (see ‘DMX Address’
below), then the display will show the DMX start
address of the block.
If individual DMX addresses have been set for each
channel, then the ‘Up & Down’ Arrows can be used to
select which DMX address to display, or alternatively if
‘Auto’ is selected, then the display will cycle through all
six DMX addresses. In either case, the DMX address is
prefixed by the channel number.
Holding down the ‘Enter’ button in default mode will
change the display to ‘Out’, and the top 6 setup LEDs
(numbered) will change to displaying an indication of
the current output levels. Each LED will be lit if the
current output level for that channel is greater than
20%.
Set-up Modes
Manual Control
The Manual Control Mode allows the user to set-up a
look on the Betapack3 without the need of an external
controller.
Select ‘Manual’ mode using the ‘Mode’ button. The
display will show C.LLL, where C is the channel number
and LLL is the level. Select the channel you require or
‘A’ for all channels, using the ‘Up & Down’ Arrows and
press ‘Enter’. Now set the level you require using the
‘Up & Down’ Arrows and press ‘Enter’ again to confirm
and move back to the channel selection.
The Manual Control levels are reset to zero if power to
the Betapack3 is lost.
DMX Address
There are 2 ways that the Betapack3 can be patched
a single DMX start address can be set for the block of 6
channels (block patch), or each channel can be given a
different DMX start address.
For block patch, the range of DMX start addresses is
001 507. For individual patch, the range of DMX start
addresses is 001 – 512
Question and Answer IconNeed help?

Do you have a question about the Zero 88 BETAPACK3 and is the answer not in the manual?

Zero 88 BETAPACK3 Specifications

General IconGeneral
Channels6
Maximum Load per Channel10A
Total Maximum Load60A
Input Voltage230V AC
Control ProtocolDMX512
Dimensions482mm x 220mm x 100mm
Fuse Rating10A

Summary

Specification Overview

Control Interface

Default Mode

Explains the default operation mode and how to view DMX addresses.

Set-up Modes

Details how to cycle through various setup modes like Manual Control and DMX Address.

Manual Control

Allows setting up looks without an external controller by adjusting channel levels.

DMX Address

Describes setting DMX addresses for blocks or individual channels.

DMX Fail

Memories

Sequences

Preheat

Topset

Dimmer Laws

Super User

Resetting The Betapack3

Firmware Version

Instructions to identify the firmware version and CPU serial number.

Internal Temperature

How to view the internal temperature of the Betapack3 in Centigrade.

Dimmer Lock/Unlock