Author: Rudi Version: 2.1 Revision: 1.2 Revision Date: June 2019
Do not try to accelerate defrosting by using any kind of heating appliance, as this
might damage the internal surfaces of the freezer. ( No sharp object be used to
scrape off the ice.)
Frost will gradually accumulate on the freezer surface. It must not be allowed
to grow thick as it acts as an insulator and adversely affects freezer
performance.
Check the formation of frost regularly and when it gets around 5mm thick,
defrost the appliance.
To defrost the appliance, turn it off and remove all food items.
Once defrosting is complete clean the interior thoroughly
PROLONGED STORAGE
Disconnect all electrical connections and the gas supply.
Empty the freezer. Defrost and clean it thoroughly as described earlier.
Leave the lid partially open to prevent any odours and moulds forming.
IMPORTANT:
Before using the freezer again, ensure that no foreign bodies are present in the flue
chimney, or the burner (dust, insect, nests, waste paper etc.)
WARNING:
The needle valve screw used for admitting the ammonia / hydrogen filling charge to
an absorption unit is fitted to the unit’s reservoir. It is a strictly applied provision of
the guarantee extended on the unit to the customer, that any interference with the
filling valve screw will automatically void the guarantee. The absorption unit must
not be opened, since it contains corroding chemicals under high pressure.
SERVICE NOTES
ROUTINE MAINTENANCE
It is recommended that a suitably qualified person service this
appliance at least once a year.
- Inspect the gas hose for cracks and chafing marks. Test all
connections with a suitable solution, do not use an open flame.
- Check there is no smell of ammonia or any signs of green/yellow
crystal-like deposits on the cooling unit tubes. Smell or deposits
indicate a leaking unit see User instructions.
- Check the functioning of the flame failure control adjust if
necessary.
- Check the functioning of the ignition device if fitted adjust if
necessary.
- Check the control knobs turn freely.