Alarm Off Message
When a networked dimmer receives an Alarm Off message and its Alarm Input is not active, the following will occur:
The dimmer exits the Alarm State.
All output channels fade to their normal levels over a period of 1s.
All menu access via the control panel is enabled.
The screen shows the main screen.
Alarm State
When the dimmer is in the Alarm State, the output levels are subject to topset, but not temperature shutdown. Manual
control levels, memories, sequences, preheat and DMX inputs do not have any contribution to the final output levels.
On power up, the alarm state of the dimmer is determined by the alarm input only, ie it does not remember any alarm
messages previously received.