EasyManua.ls Logo

Zero88 Chilli Pro Series - Menu Structure

Zero88 Chilli Pro Series
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Temp Field in the Default Screens
The Temp field in the default screen will show the status of the temperature sensor. During startup the text “Temp: No
Val” is shown briefly whilst the dimmer is reading the sensor. This is normal behaviour.
Internal temperature sensor fault:
“Temp: No Val”
Normal operating temperature (<80 C):
“Temp: OK”
Hot (80 - 90 C):
“Temp: HOT”
Overheat shutdown (> 95 C)
“Temp: FAIL”
ChilliNet Field in the Default Screens
If the dimmer is operating in ChilliNet mode, the second line of the screen shows “Chilli Net: xx”, where xx is the
dimmer number.
If the dimmer is in ‘dumb’ mode as a result of conflicting dimmer numbers on the network, the screen shows: “Chilli
Net: CON”.
Menu Structure
From the Main Screen, press the ENT key to enter the menu structure. The menu structure is cyclic and the cursor
keys are used for navigation.
After selecting a top level menu option, press the ENT key to enter the corresponding sub-menu. Hitting the ESC
key on a screen generally returns to the menu level above the current one, except where specifically stated in this
manual.
Zero 88 - Chilli Pro - Page 16 of 60 Printed: 23/03/2021 09:13:40 ES