Overview of the RTU's role in a wireless SCADA telemetry system.
Explains the typical SCADA system architecture with controllers and RTUs.
Describes the MODBUS protocol and its use with Zetron controllers and RTUs.
Details standard input/output connections for the RTU, like digital and analog interfaces.
Outlines power, current, temperature, size, and weight of the RTU.
Lists serial communication parameters like baud rate, parity, bits, and stop bits.
Details audio output/input, channel busy input, and PTT output specifications.
Specifies data rate and signaling method for the radio modem.
Covers required signal strength and probability of false data.
Details capabilities of external inputs and outputs, including types and counts.
Explains the two primary tasks of RTUs: reporting changes and responding to commands.
Describes how to assign unique addresses to RTUs using DIP switches.
Outlines the process and requirements for configuring an RTU for specific applications.
Details the steps to enter the RTU's programming mode via serial connection.
Sets the delay between PTT activation and MSK signaling start.
Configures how the RTU identifies if the radio channel is in use.
Details RTU behavior under abnormal conditions and communication failure settings.
Explains the store-and-forward feature for extending radio range.
Covers configuration options for digital inputs, including debounce and status modes.
Details configuration for digital outputs, such as latched or momentary modes.
Explains configuration for analog inputs, including thresholds and sampling rates.
Discusses operational limits related to inputs, outputs, and system interfaces.
Describes the optional MODBUS protocol implementation for controllers and RTUs.
Explains the two setup methods: Polled-only and Report-by-Exception.
Lists requirements for PC or PLC software to be compatible with the MODBUS system.
Guides on setting up the Model 1700 controller for MODBUS operation.
Details configuration steps for RTUs when interfaced directly or via a controller.
Provides general guidelines for configuring master software or PLCs.
Explains MODBUS nomenclature for I/O addressing and Zetron equivalents.
Discusses configuring masters to access RTU accumulators and counters.
Lists compatible third-party software packages for the MODBUS option.
Covers wall-mounting and enclosure installation instructions for the RTU.
Details the physical connections and jumper settings for radio interface.
Guides on adjusting transmit and receive audio levels for proper radio communication.
Provides detailed jumper and I/O connector information specific to the Model 1708.
Provides detailed jumper and I/O connector information specific to the Model 1716.
Explains how to connect an RTU locally to a Model 1700 controller.
Describes the 50-pin connector for interfacing with industrial I/O boards.
Explains the RTU's microprocessor-based architecture and versatility.
Illustrates the internal components and data flow within the RTU.
Provides initial steps for troubleshooting and contact information for Zetron support.
Instructions on how to safely remove and replace the unit's cover.
Provides dimensional drawings and outline for the Model 1700 enclosure.
Detailed instructions for installing the Model 1700 enclosure.
Silkscreen diagram showing component layout for Model 1708.
Silkscreen diagram showing component layout for Model 1716.
Discusses connecting RTUs over wireline for long-distance data transmission.
Introduces a troubleshooting tool for testing controller and RTU communications.
Explains how to launch the communications and I/O test program.
Describes how to configure the test program, including device and port settings.
Details how to retrieve status and hardware information using the Poll menu.
Explains how to control outputs and change logic registers using the Set menu.
Outlines how to clear message windows, counters, runtimes, and accumulators.
Remote Terminal Unit, a stand-alone device for data acquisition and control in the field.
Industry-standard protocol used for process control, transferring commands and data.
Supervisory Control And Data Acquisition, a system for industrial measurement and control.
SCADA system where the master controls all communication; RTUs respond only to polls.
Feature allowing an RTU to receive and resend messages to extend communication range.
Method to prevent multiple reports when a signal crosses a threshold value.